Human PECAM-1/CD31 ELISA Kit PicoKine®

CD31/PECAM-1 ELISA kit for Human

Human PECAM-1/CD31 ELISA Kit PicoKine™ (96 Tests). Quantitate Human PECAM1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. Cited in 1 publication(s).

Product Info Summary

SKU: EK0873
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Human PECAM-1/CD31 ELISA Kit PicoKine®

View all CD31/PECAM-1 ELISA kits

SKU/Catalog Number

EK0873

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human PECAM-1/CD31 ELISA Kit PicoKine™ (96 Tests). Quantitate Human PECAM1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human PECAM-1/CD31 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0873)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: CHO; Immunogen sequence: Q28-K601

Sensitivity

<10 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK0873 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0873 is reactive to PECAM1 in Human samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0873 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CD31/PECAM-1

Human platelet/endothelial cell adhesion molecule-1 (PECAM1), an important member of the immunoglobulin gene superfamily, is widely distributed on cells of the vascular system and mediates cellular interactions through both homophilic and heterophilic adhesive mechanisms. The function of PECAM1 in vitro has begun to be understood, but its function in vivo is yet to be established.1 The PECAM1 locus is on the long arm of chromosome 17, in the region q23-qter. To confirm this observation and obtain a more precise localization of the PECAM1 locus, fluorescence in situ hybridization was conducted. Together our data allowed assignment of the PECAM1 locus to the region 17q23.2 To examine the functional role of PECAM-1 in regulating platelet-collagen interactions, 2 different approaches were applied using recombinant human PECAM-1-immunoglobulin chimeras and platelets derived from PECAM-1-deficient mice.3 PECAM-1, an integral membrane protein with an essential role in TEM, is found in this compartment and constitutively recycles evenly along endothelial cell borders.4 The standard used in this kit is the product of gene recombinant expression (extracellular part), consisting of 574 amino acids (Q28-K601) with the molecular weight of 64.5KDa. After glycosylating, its molecular weight changes to 90-100KDa.

Kit Components

Catalog Number Description Quantity
EK0873-CAP Anti-Human PECAM1 Pre-coated 96-well strip microplate 1
EK0873-ST Human PECAM1 Standard 2 vials, 10 ng/tube
EK0873-DA Human PECAM1 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512502500500010000
O.D.0.0490.1440.2190.3750.6451.0491.6142.074

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CD31/PECAM-1, Dilution ratio of 1:10, concentration in serum and plasma is around 10 ng/ml..

Some articles we found to cite concentrations of CD31/PECAM-1 in samples: 11571836 (Pubmed IDs).

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human PECAM-1/CD31 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)2921327478127814424709
Standard deviation11.6887.58310.7613.62114.94367.3
CV (%)4%6.6%6.5%4.9%8.2%7.8%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CD31/PECAM-1 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 129228632727629519.26.5%
Sample 21327142815631332141295.766.7%
Sample 347814159468541864452282.456.3%
*number of samples for each test n=16.

Gene/Protein Information For PECAM1 (Source: Uniprot.Org, NCBI)

Gene Name

PECAM1

Full Name

Platelet endothelial cell adhesion molecule

Weight

82.522kDa

Alternative Names

adhesion molecule; CD31 antigen; CD31; CD31/EndoCAM; EndoCAM; FLJ34100; FLJ58394; GPIIA'; PECA1; PECAM1; PECAM-1; PECAM-1, CD31/EndoCAM; platelet endothelial cell adhesion molecule; platelet/endothelial cell adhesion molecule PECAM1 CD31, CD31/EndoCAM, GPIIA, PECA1, PECAM-1, endoCAM platelet and endothelial cell adhesion molecule 1 platelet endothelial cell adhesion molecule|CD31 antigen|platelet endothelial cell adhesion molecule-1

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on PECAM1, check out the PECAM1 Infographic

PECAM1 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for PECAM1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK0873 has been cited in 1 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Wang Tb, Wei Xq, Lin Wh, Shi Hp, Dong Wg. Clin Exp Med. 2012 Jun;12(2):89-95. Doi: 10.1007/S10238-011-0143-8. Epub 2011 Jun 10. The Inhibition Of Endostar On The Angiogenesis And Growth Of Gastrointestinal Stromal Tumor Xenograft.

Have you used Human PECAM-1/CD31 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $25/€18/£15/$25CAN/¥75 Yuan/¥1250 Yen for a review with an image
  • $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit A Review

Be the first to review Human PECAM-1/CD31 ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

6 Customer Q&As for Human PECAM-1/CD31 ELISA Kit PicoKine®

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

S. Allen

Verified customer

Asked: 2020-12-08

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2020-12-08

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification CD31 using the EK0873 Human CD31 Picokine® ELISA Kit?

J. Davis

Verified customer

Asked: 2020-10-09

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to prevent protein degradation.

Boster Scientific Support

Answered: 2020-10-09

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2019-04-16

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2019-04-16

Question

Q: how to analyze ELISA data? I have obtained CD31 level in cell lysates.

Verified Customer

Verified customer

Asked: 2019-03-01

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2019-03-01

Question

Q: if the enzyme conjugated CD31 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CD31 antigen?

Verified Customer

Verified customer

Asked: 2019-02-10

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2019-02-10

Question

Q: Can CD31 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

G. Wu

Verified customer

Asked: 2016-07-03

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is a must. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2016-07-03

$499
In stock, 3+ left.

Order within 88 hours and 18 minutes to receive by Tue Apr 2

Get A Quote
Eddy test
In stock
Order Product
EK0873
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.