3 Main Types of IHC/ICC Fixatives

Greetings Earthling,

Sample fixation is a required and crucial step for every successful IHC/ICC experiment. Appropriate fixation of samples provides the following benefits during the tissue preparation process:
 Preserves morphology
 Prevents tissue degradation
 Ensures antigenicity
 Protects cells from damage
Choosing which fixing solution to use depends on your sample type and antigen. Since there is no standard fixing solution for all samples, we recommend testing to determine which specific type of solution will be most appropriate and effective for antigen immobilization in your sample.

As an example, compare the morphologies demonstrated below using different fixatives, both photographed at the same magnification.
IHC Fixatives Formalin and Ethanol
On the left: A paraffin section of the small intestine mucosa that has been fixed in neutral buffered formalin, a cross-linking fixative. Nuclear and cytoplasmic preservation is satisfactory but some cellular shrinkage is present.

On the right: A paraffin section of the small intestine mucosa that has been fixed in 95% ethanol, a denaturing fixative. While nuclear preservation is fair, there is substantial shrinkage of cytoplasmic and extracellular elements.

Several fixing solutions are available for use and should be chosen based on the sample type or antigen studied in the experiment. Below are the 3 different categories of fixatives:
Aldehyde Fixatives

Aldehyde fixatives are di-functional cross-linking agents, which are widely used due to their strong penetrability, low contractibility, and low background. They help keep the cross-linking between tissues and maintain the antigen.
Aldehyde Fixatives di-functional cross-linking agents
Examples include: Formaldehyde/Formalin (most common fixative), Paraformaldehyde, Glutaraldehyde, Bouin’s solution, Zamboni’s solution.

What is the difference between formaldehyde, formalin, and paraformaldehyde?

Formaldehyde and formalin are often referred to interchangeably. They are similar, but their chemical compositions are in fact different. Formalin (aka NBF) is a saturated water solution consisting of 37 to 40% (w/v) formaldehyde, which is diluted with a phosphate buffer to decelerate polymerization to formaldehyde. As a result, formalin’s fixing ability is decreased.

Paraformaldehyde (or polyoxymethylene) is polymerized formaldehyde powder. Dissolving paraformaldehyde in hot distilled water and adding 10% (v/v) methanol will produce the stabilized formaldehyde solution.
Precipitating Fixatives 

Acetone and alcohol play the role of precipitating sugars and fat in addition to maintaining immunologic competence. Acetone is often chosen for unfixed, snap-frozen tissues and cytological smears due to its strong penetrability and dehydration property. Methanol and ethanol are the most common alcohols selected for cell and tissue fixation because of the similarities of their molecular structures with water, which enables them to substitute water molecules in tissues by competing for protein hydrogen bonds.
Non-Aldehyde Fixatives

In cases where aldehyde or precipitating fixatives are not optimal choices for the sample type or antigen, non-aldehyde fixatives have been used as alternatives.

Examples:
 Mercuric chloride-based fixatives: These fixatives provide more intense IHC staining while preserving cytological details more effectively than aldehydes. However, this alternative also results in tissue hardening, which may be troublesome.
 Diimidoester fixation: This fixation method utilizes dimethyl suberimidate (DMS), which offers the advantages of retaining antigen immunoreactivity and eliminates the need to block aldehyde groups.
 Other non-aldehyde fixatives include carbodiimide, dimethylacetamide, para-benzoquinone, etc.
Note: In some situations, these non-aldehyde fixation agents can be mixed with other tissue fixatives for a more optimal solution.
Click the banner below to download Boster's IHC protocols and troubleshooting handbook.
See IHC technical resources
IHC protocols and troubleshooting guide handbook
Download IHC
protocols and troubleshooting handbook
Download eBook

Why Boster?

Get better results with Boster!
Boster takes great measures to ensure product quality and to provide our customers with comprehensive data upfront. Our antibodies are validated using WB, IHC, and flow cytometry against a panel of over 250 tissues and un-transfected cell lines to ensure high affinity and crystal-clear IHC stains. In addition, we also validate our antibodies in a quantitative fashion by testing them on known quantities of recombinant proteins so that you know what to expect (e.g. if there is 1ng, 2.5ng or 5ng of the target protein in the sample). Every product is covered by the Boster Quality Guarantee, click below to learn more.
Learn More

Supporting Our Customers

Have questions? We're here to help.
Contact Us
BosterBio | Antibodies ,ELISA kits , Detection Kits 3942 B Valley Ave, Pleasanton, CA, 94566
Office: 888.466.3604
Boster Biological Technology
Follow us on Facebook Follow us on Twitter
© 2018. All rights reserved