Product Info Summary
| SKU: | EK0696 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Human |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, serum, plasma (heparin, EDTA) , saliva and urine. |
Product info
Product Name
Human CD26/DPP4 ELISA Kit PicoKine®
SKU/Catalog Number
EK0696
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human CD26/DPP4 ELISA Kit PicoKine® (96 Tests). Quantitate Human DPP4 in cell culture supernatants, serum, plasma (heparin, EDTA) , saliva and urine. Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human CD26/DPP4 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0696)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: D34-P766
Sensitivity
<10 pg/ml
Assay Range
312 pg/ml - 20,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0696 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0696 is reactive to DPP4 in Human samples
Validated Sample Types
cell culture supernatants, serum, plasma (heparin, EDTA) , saliva and urine.
Application Guarantee
EK0696 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of DPP4
Dipeptidyl peptidase-4 (DPP4), also known as adenosine deaminase complexing protein 2 or CD26 (cluster of differentiation 26) is a protein that, in humans, is encoded by the DPP4 gene. By fluorescence in situ hybridization, the CD26 gene was mapped to 2q24.3. DPP4 plays a major role in glucose metabolism. It is responsible for the degradation of incretins such as GLP-1. Furthermore, it appears to work as a suppressor in the development of cancer and tumours. CD26/ DPP4 plays an important role in tumor biology, and is useful as a marker for various cancers, with its levels either on the cell surface or in the serum increased in some neoplasms and decreased in others.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0696-CAP | Anti-Human DPP4 Pre-coated 96-well strip microplate | 1 |
| EK0696-ST | Human DPP4 Standard | 2 vials, 20 ng/tube |
| EK0696-DA | Human DPP4 Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data
Validation Standard Curve O.D. At 450nm
| Concentration (ng/ml) | 0 | 0.312 | 0.62 | 1.25 | 2.5 | 5 | 10 | 20 |
| O.D. | 0.035 | 0.101 | 0.162 | 0.3 | 0.542 | 0.928 | 1.523 | 2.176 |
Data Example Images
Click image to see more details
Human CD26/DPP4 PicoKine ELISA Kit standard curve
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human CD26/DPP4 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 590 | 3074 | 9263 | 536 | 3241 | 9182 |
| Standard deviation | 26.55 | 196.73 | 574.3 | 26.26 | 269 | 661.1 |
| CV (%) | 4.5% | 6.4% | 6.2% | 4.9% | 8.3% | 7.2% |
Specific Publications For Human CD26/DPP4 ELISA Kit PicoKine® (EK0696)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Human CD26/DPP4 ELISA Kit PicoKine®
Submit your question