Mouse TIE2/TEK ELISA Kit PicoKine®

Tie-2 ELISA kit for Mouse

Mouse TIE2 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Tek in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. Cited in 1 publication(s).

Product Info Summary

SKU: EK0976
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA).

Product Name

Mouse TIE2/TEK ELISA Kit PicoKine®

View all Tie-2 ELISA kits

SKU/Catalog Number

EK0976

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse TIE2 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Tek in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse TIE2/TEK ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0976)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: A23-K744

Sensitivity

<10 pg/ml

Assay Range

125 pg/ml - 8,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK0976 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0976 is reactive to TEK in Mouse samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA).

Application Guarantee

EK0976 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Tie-2

Angiopoietin-1 receptor, also called TEK or TIE2 is a protein that in humans is encoded by the TEK gene. This gene is mapped to 9p21.2. The TEK receptor tyrosine kinase is expressed almost exclusively in endothelial cells in mice, rats, and humans. This receptor possesses a unique extracellular domain containing 2 immunoglobulin-like loops separated by 3 epidermal growth factor-like repeats that are connected to 3 fibronectin type III-like repeats. The ligand for the receptor is angiopoietin-1. Defects in TEK are associated with inherited venous malformations, the TEK signaling pathway appears to be critical for endothelial cell-smooth muscle cell communication in venous morphogenesis. TEK is closely related to the TIE receptor tyrosine kinase.

Kit Components

Catalog Number Description Quantity
EK0976-CAP Anti-Mouse TEK Pre-coated 96-well strip microplate 1
EK0976-ST Mouse TEK Standard 2 vials, 10 ng/tube
EK0976-DA Mouse TEK Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)01252505001000200040008000
O.D.0.0380.0660.10.160.2990.5681.1932.153

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Tie-2, For serum, dilution ratio is 1:10 and concentration is around 10 ng/ml.
For plasma, dilution ratio is 1:1 and concentration is 1180-3122 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse TIE2/TEK ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)1581232483614512954385
Standard deviation7.966.52203.117.9790.65210.48
CV (%)5%5.4%4.2%5.5%7%4.8%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Tie-2 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 11581741731641676.63.9%
Sample 21232122312551137121144.73.6%
Sample 348364677489550264858125.332.5%
*number of samples for each test n=16.

Gene/Protein Information For TEK (Source: Uniprot.Org, NCBI)

Gene Name

TEK

Full Name

Angiopoietin-1 receptor

Weight

125.83kDa

Superfamily

protein kinase superfamily

Alternative Names

angiopoietin-1 receptor; CD202b antigen; CD202b; EC 2.7.10; EC 2.7.10.1; hTIE2; p140 TEK; soluble TIE2 variant 1; soluble TIE2 variant 2; TEK tyrosine kinase, endothelial; TEK; Tie2; Tie-2; TIE2CD202b; Tunica interna endothelial cell kinase; Tyrosine-protein kinase receptor TEK; Tyrosine-protein kinase receptor TIE-2; venous malformations, multiple cutaneous and mucosal; VMCM; VMCM1 TEK CD202B, GLC3E, TIE-2, TIE2, VMCM, VMCM1 TEK receptor tyrosine kinase angiopoietin-1 receptor|TEK tyrosine kinase, endothelial|endothelial tyrosine kinase|tunica interna endothelial cell kinase|tyrosine kinase with Ig and EGF homology domains-2|tyrosine-protein kinase receptor TEK|tyrosine-protein kinase receptor TIE-2

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on TEK, check out the TEK Infographic

TEK infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for TEK: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK0976 has been cited in 1 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Sancakdar E, Guven As, Uysal Eb, Deveci K, G??lt??rk E. Pediatr Infect Dis J. 2015 Aug;34(8):E200-5. Doi: 10.1097/Inf.0000000000000706. Important Of Angiopoietic System In Evaluation Of Endothelial Damage In Children With Crimean-Congo Hemorrhagic...

Have you used Mouse TIE2/TEK ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $25/€18/£15/$25CAN/¥75 Yuan/¥1250 Yen for a review with an image
  • $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit A Review

Be the first to review Mouse TIE2/TEK ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Mouse TIE2/TEK ELISA Kit PicoKine®

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2019-08-29

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2019-08-29

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

T. Dhar

Verified customer

Asked: 2019-06-26

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2019-06-26

Question

Q: how do I analyze ELISA data? I have obtained Tie-2 level in serum.

Verified Customer

Verified customer

Asked: 2019-06-01

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2019-06-01

Question

Q: we need your recommendation regarding the dilution ratio of serum samples for detection of Tie-2 in Mouse serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.

H. Taylor

Verified customer

Asked: 2018-10-24

Answer

A: unable to understand the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the Tie-2 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2018-10-24

Question

Q: if the enzyme conjugated Tie-2 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Tie-2 antigen?

R. Perez

Verified customer

Asked: 2018-09-13

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2018-09-13

Question

Q: can I use citrate plasma as samples in Mouse Tie-2 Picokine® ELISA Kit (Catalog # EK0976)?

Verified Customer

Verified customer

Asked: 2017-09-19

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can sequester metal ions from the functional domain of Tie-2 causing disruption of its protein structure. Tie-2 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the Tie-2 ELISA, treating samples with different anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2017-09-19

Question

Q: Can Tie-2 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2017-04-26

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is a must. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2017-04-26

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis Tie-2 using the EK0976 Mouse Tie-2 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2016-11-21

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. avoid repetitive freeze-thaw cycles with the stored samples to limit protein degradation.

Boster Scientific Support

Answered: 2016-11-21

Question

Q: What is the optimal O.D. value for Tie-2 ELISA kit? I performed your Tie-2 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain Tie-2 even though the O.D. values are not very high?

M. Maharaj

Verified customer

Asked: 2015-02-26

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this Tie-2 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of Tie-2 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2015-02-26

$499
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
Eddy test
In stock
Order Product
EK0976
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.