Customer Testimonials

Peer Reviews from Real Labs

Browse peer-submitted results linked to specific products—ratings, images, and practical notes included. Contribute your own result to strengthen the evidence base and claim rewards after verification.

Video Interviews

See real workflows and decision points—what researchers tried, what worked, and why. Share your story in a short interview and claim rewards!

Get Interview Rewards

Filter by category, reactivity, and host to find the most relevant peer results.

Human T4 ELISA Kit from Boster

Excellent, submitted by on

Source: Biocompare.com

SKU EK7012
Application Human T4 levels in Dried Blood Spots
Starting Material Dried Blood Spots
Tips This is a competitive ELISA without a 0 standard or a diluent, PBS makes a reliable diluent for patient samples and standards.
Results Summary Results were repeatable and reliable using dried blood spots. The highest concentration standard sometimes fell OWR, but the low end stayed within reading capabilities.

"The goal of this experiment is to quantify the levels of human T4 in dried blood spots from at-home test kits. This assay in combination with other hormone tests is aimed at providing accurate and timely healthcare to patients remotely."

Human Testosterone ELISA Kit From Boster

Excellent, submitted by on

Source: Biocompare.com

SKU EK7005
Application Human Testosterone saliva levels
Starting Material Saliva
Tips Do not use water or PBS to dilute patient sample or standards.
Results Summary The results from this assay were easily obtained, repeatable, and reliable. The standard curve was accurate and precise, resulting it quality result for patient samples.

"The experiment goal was to quantify the levels of testosterone in human saliva with this booster kit designed for blood or serum samples. The aim is to provide at-home test kits for remote patients using a non-invasive collection method."

The antibody worked well even though we used fresh frozen brain sections cut at 20 micron thickness thaw-mounted onto microscope slide that were then post-fixed with 4% paraformaldehyde. The antibody worked equally well when used on fixed brains sectioned

Excellent, submitted by on

Boster bio GFAP 1:100 PFA (7-2) - cortex 12x - with scale bar




Boster bio GFAP 1:100 PFA (7-2) - cortex 20x - with scale bar




Boster bio GFAP 1:250 12x (free-floating)

SKU PB9082
Application Immunofluorescence
Sample Mouse brain
Primary Antibody Dilution 1:100

Images that were made from fresh frozen cryostat sections, were thaw-mounted onto microscope slides. Mounted sections were later post-fixed with 300 µL of 4% paraformaldehyde (PFA) in PBS at room temperature for 10 minutes. After fixation and prior to incubation with antibodies, slides were washed 3 times with 300 µL of 1X PBS with 0.01% sodium azide for 3 minutes per rinse, followed by permeabilization with 300 µL of 0.3% Triton X-100 in 1X PBS with 0.01% sodium azide for 30 minutes at room temperature, then blocking with 700 µL of 4% donkey serum diluted in 1X PBS with 0.01% sodium azide + Triton X-100 (blocking buffer) for 30 minutes at room temperature. Slides were incubated with 325 µL of GFAP (1:100). Concentrations of 1:100 were achieved by diluting 10 µL of antibody in 1,000 µL of blocking buffer; concentrations of 1:250 were achieved by diluting 4 µL of antibody in 1,000 µL of blocking buffer. Sections were incubated overnight at 4 ˚C. On the next day, slides were washed 3 times with 300 µL of 1X PBS with 0.01% sodium azide for 3 minutes per rinse, then incubated with the secondary antibodies at room temperature, in the dark, for 1 hour. Washing step was repeated then slides were left in the dark to dry. Mounting media was added to cover slip the sections. Slides were kept in the dark at 4 ˚C prior to imaging.

Immunohistochemistry was also performed with free-floating sections, which were exposed to the same primary antibodies diluted (1:250) in blocking buffer overnight and, subsequently, exposed to secondary antibodies diluted in blocking buffer for 1 hour, following the same procedure as the mounted sections. After incubation, sections were washed 3 times with 300 µL of 1X PBS with 0.01% sodium azide for 3 minutes per rinse and transferred with a painting brush to a container filled with 1X PBS with 0.01% sodium azide, from which they were mounted onto slides. Slides were left to dry in the dark, after which mounting media was added to cover slip the sections. As with slide-mounted sections, these slides were kept in the dark at 4 ˚C prior to imaging.

Immunohistochemistry for Anti-CD31/PECAM1 Antibody

Excellent, submitted by on
SKU M01513-4
Application Immunohistochemistry (Paraffin-embedded)
Blocking step 5% BSA as a blocking agent for 30 min at 37°C
Sample Human Lung
Fixative Fixed with 4% paraformaldehyde
Primary Ab Incubation 37°C for 30 minutes
Primary Ab Incubation diluent 5% BSA in TBS
Primary Ab Concentration 1ug/ml
Secondary Antibody SABC kit from Boster Bio, (SA1022)
Secondary Ab Dilution The kit was ready to use, no dilution needed
Secondary Ab Incubation at 37°C for 30 min

Good GATA3 Antibody from BosterBio

--Xiangrong Geng Internal medicine University of Michigan Postdoctoral Researcher

Excellent, submitted by on

Source: Biocompare.com

SKU M00593
Application Western Blot
Sample HEK293T
Detection ECL

"I used this antibody for western blotting and immunoprecipitation. It works well in both of them. Very good antibody."

Good Mouse IL-12 ELISA Kit

--Daisy Dai University of Miami Surgery Lab Director / Manager

Excellent, submitted by on

Source: Biocompare.com

SKU EK0422
Application ELISA
Starting Material Crispr MEK and STAT3 KO CAFs
Tips This kit doesn't provide PC

"We investigate how alterations in RAS and STAT3 signaling pathways affect the tumor stroma and immune microenvironment in pancreatic cancer. This kit was used to detect the IL-12 level in CM from Crispr MEK and STAT3 KO CAFs. The whole process was about 7 hours including sample preparation."

Easy to Use Human Laminin ELISA Kit

--John Ong, University of Cambridge Engineering Graduate Student

Excellent, submitted by on

Source: Biocompare.com

SKU EK0434
Application Testing laminin concentration in hydrogel
Starting Material Hydrogel
Tips Supernatant used for ELISA

"Positive:(1) Very straight forward and easy to use kits.(2) Accurate results(3) Removable well-strips so experiments can be staggered.Negative:(1) Price point - could be cheaper(2) Reagents have to be used within 1 month upon defrosting."

Immunocytochemistry for Anti-E Cadherin 1/CDH1 Antibody

Excellent, submitted by on
PB9561 Immunohistochemistry

The antibody worked perfectly, Great sensitivity

SKU PB9561
Application Immunohistochemistry (paraffin-embedded)
Blocking step 5% BSA as a blocking agent for 30 min at 37°C
SampleMouse Liver
Fixative Fixed with 4% paraformaldehyde
Primary Ab Incubation 4°C overnight
Primary Ab Incubation diluent 5% BSA in TBS
Primary Ab Concentration 2ug/ml
Secondary Antibody SABC kit from Boster Bio, (SA1022)
Secondary Ab Dilution The kit was ready to use, no dilution needed
Secondary Ab Incubation 4°C overnight

Immunohistochemistry for Anti-E Cadherin 1 CDH1 Antibody

Excellent, submitted by on
SKU M00063-2
Application Immunohistochemistry (Paraffin-embedded)
Blocking step 5% BSA as a blocking agent for 30 min at 37°C
Sample Human Oesophagus
Fixative Fixed with 4% paraformaldehyde
Primary Ab Incubation 4°C overnight
Primary Ab Incubation diluent 5% BSA in TBS
Primary Ab Concentration 2ug/ml
Secondary Antibody SABC kit from Boster Bio, (SA1022)
Secondary Ab Dilution The kit was ready to use, no dilution needed
Secondary Ab Incubation at 37°C for 30 min

Great PKC antibody for IHC

Excellent, submitted by on
We used Anti-PKC Alpha Picoband™ Antibody (SKU: PB9318) for IHC experiment from mouse intestine tissues. Clear positive staining with the right subcellular locations. Super easy to determine the dilution ratio! Great quality.