Product Info Summary
| SKU: | A04812-1 |
|---|---|
| Size: | 100 μl/vial |
| Reactive Species: | Human, Mouse, Rat |
| Host: | Rabbit |
| Application: | ELISA, IHC, WB |
Customers Who Bought This Also Bought
Product info
Product Name
Anti-ESCO2 Antibody
SKU/Catalog Number
A04812-1
Size
100 μl/vial
Form
Liquid
Description
Boster Bio Anti-ESCO2 Antibody catalog # A04812-1. Tested in WB, IHC, ELISA applications. This antibody reacts with Human, Mouse, Rat.
Storage & Handling
12 months from date of receipt,-20℃ as supplied. 6 months 2 to 8℃ after reconstitution. Avoid repeated freezing and thawing.
Cite This Product
Anti-ESCO2 Antibody (Boster Biological Technology, Pleasanton CA, USA, Catalog # A04812-1)
Host
Rabbit
Contents
500 μg/ml antibody with PBS, 0.02% NaN3, 1 mg stabilizing protein and 50% glycerol
*This antibody is supplied in a stabilized formulation.
Compatibility with conjugation reactions depends on the chemistry of the conjugation method used.
For conjugation methods that are not compatible with the stabilizing components present in this formulation, a carrier-free antibody format is required.
Clonality
Polyclonal
Immunogen
E.coli-derived human ESCO2 recombinant protein (Position: A3-V350).
Reactive Species
A04812-1 is reactive to ESCO2 in Human, Mouse, Rat
Observed Molecular Weight
70 kDa
Calculated molecular weight
68.3 kDa
Background of ESCO2
ESCO2 is also known as Establishment of Sister Chromatid Cohesion N-Acetyltransferase 2, EFO2. This gene encodes a member of the family of acetyltransferases involved in the establishment of sister chromatid cohesion during S phase and postreplicative sister chromatid cohesion induced by double-strand breaks (PubMed: 15821733). Mutations in the ESCO2 gene are associated with a rare genetic disorder called Roberts syndrome or SC phocomelia syndrome (PubMed: 16380922). The loss of function or impaired activity of the ESCO2 protein due to mutations disrupts the proper cohesion of sister chromatids, leading to chromosomal abnormalities and the characteristic features of Roberts syndrome. ESCO2 can be detected as about 65-70 kDa.
Antibody Validation
Boster validates all antibodies on WB, IHC, ICC, Immunofluorescence, and ELISA with known positive control and negative samples to ensure specificity and high affinity, including thorough antibody incubations.
Application & Images
Applications
A04812-1 is guaranteed for ELISA, IHC, WB Boster Guarantee
Assay Dilutions Recommendation
The recommendations below provide a starting point for assay optimization. The actual working concentration varies and should be decided by the user.
Western blot, 1:500-2000
Immunohistochemistry, 1:50-400
ELISA, 1:100-1000
Positive Control
WB: human Hela whole cell, human HepG2 whole cell, human A431 whole cell, human U20S whole cell, rat testis tissue, rat RH35 whole cell, mouse testis tissue, mouse HEPA1-6 whole cell
Validation Images & Assay Conditions
Click image to see more details
Western blot analysis of ESCO2 using anti-ESCO2 antibody (A04812-1).
Electrophoresis was performed on a 10% SDS-PAGE gel at 80V (Stacking gel) / 120V (Resolving gel) for 2 hours. The sample well of each lane was loaded with 30 ug of sample under reducing conditions.
Lane 1: human Hela whole cell lysates,
Lane 2: human HepG2 whole cell lysates,
Lane 3: human A431 whole cell lysates,
Lane 4: human U20S whole cell lysates,
Lane 5: rat testis tissue lysates,
Lane 6: rat RH35 whole cell lysates,
Lane 7: mouse testis tissue lysates,
Lane 8: mouse HEPA1-6 whole cell lysates.
After electrophoresis, proteins were transferred to a nitrocellulose membrane at 150 mA for 50-90 minutes. Blocked the membrane with 5% non-fat milk/TBS for 1.5 hour at RT. The membrane was incubated with rabbit anti-ESCO2 antigen affinity purified polyclonal antibody (A04812-1) at 1:1000 overnight at 4°C, then washed with TBS-0.1%Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:5000 for 1.5 hour at RT. The signal is developed using an ECL Plus Western Blotting Substrate (Catalog # AR1196-200) with Tanon 5200 system. A specific band was detected for ESCO2 at approximately 70 kDa. The expected band size for ESCO2 is at 68 kDa.
Specific Publications For Anti-ESCO2 Antibody (A04812-1)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Anti-ESCO2 Antibody?
Share your experimental results or join a short interview to earn up to $1,000 in product credits or other rewards.
0 Reviews For Anti-ESCO2 Antibody
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question

