This website uses cookies to ensure you get the best experience on our website.
- Table of Contents
ME1 antibody (A03449-3) performs well in ELISA, Flow Cytometry, IF, IHC, ICC, WB and shows reactivity with Human, Mouse, Rat.
| Reactive Species | Host | Application |
|---|---|---|
| Human, Mouse, Rat | Rabbit | ELISA, Flow Cytometry, IF, IHC, ICC, WB |
ME1 antibody was positively detected by WB in:
human CACO-2 whole cell, human A549 whole cell, human Hela whole cell, human Hacat whole cell, rat liver tissue, rat kidney tissue, mouse liver tissue, mouse kidney tissue
Suggested blocking solution with 5% non-fat milk or BSA; (*)Recommended protein loading: 20-40 ug per lane
ME1 antibody was positively detected by IHC in:
human stomach cancer tissue
Use TE buffer pH 9.0 for antigen retrieval; (*) citrate buffer pH 6.0 is an alternative.
ME1 antibody was positively detected by ICC/IF in:
A549 cell
ME1 antibody was positively detected by IF in:
human gastric cancer
ME1 antibody was positively detected by FC in:
A549 cell
* It is recommended to optimize the amount of this reagent in each experimental system to achieve the best results.
Note: For flow cytometry (FCM), validated for fixed cells only. Not validated for FACS or surface flow cytometry using live cells.
64.2 kDa
Submit a review and receive $370 in product credits, a $185 Amazon gift card, or our carefully curated gift bundles.

| SKU | A03449-3 |
|---|---|
| Application | Western Blot |
| Sample | Human keratinocytes isolated from skin |
| Sample Processing Description | Human Caco-2 cell line |
| Other Reagents | RIPA lysis buffer, Protease inhibitor, Electrophoresis buffer, Transfer buffer, Blocking buffer |
| Primary Antibody | ME1 Antibody Picoband® |
| Primary Incubation | 1:2000, overnight at 4 ℃ |
| Secondary Antibody | HRP Goat Anti-Rabbit IgG |
| Secondary Incubation | 1:10000, 1 hour in room temperature |
| Detection | Substrate: ECL, Imaging system:ChemiDoc MP |
| Results Summary | The protein level of ME1 in LPS-stimulated CACO-2 cells is higher than that in normal CACO-2 cells. |
Yuantao Mao, Shandong First Medical University
Verified customer
Submitted 2025-12-10
We promise Anti-ME1 Antibody Picoband® performs excellently in relevant applications for ELISA, Flow Cytometry, IF, IHC, ICC, WB. If it doesn't perform as promised, we will refund the product. Learn more
We promise all of our products perform as described in datasheets.
This product is for Research Use Only. Not for use in diagnostic procedures.