Human Relaxin 1 ELISA Kit PicoKine®

Relaxin-1 ELISA kit for Human

Human Relaxin 1 ELISA Kit PicoKine™ (96 Tests). Quantitate Human RLN1 in cell culture supernatants, serum and plasma (heparin). Sensitivity: 10pg/ml.

Product Info Summary

SKU: EK1230
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin).

Product Name

Human Relaxin 1 ELISA Kit PicoKine®

View all Relaxin-1 ELISA kits

SKU/Catalog Number

EK1230

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human Relaxin 1 ELISA Kit PicoKine™ (96 Tests). Quantitate Human RLN1 in cell culture supernatants, serum and plasma (heparin). Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human Relaxin 1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1230)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: E.coli; Immunogen sequence: R162-Cys185 (A) & K26-S53 (B)

Sensitivity

<10 pg/ml

Assay Range

78 pg/ml - 5,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1230 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1230 is reactive to RLN1 in Human samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin).

Application Guarantee

EK1230 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Relaxin-1

Relaxin 1 is a member of relaxin-like peptide family. Relaxin gene maps to human chromosome 19 near D19Mit23. Relaxin is a peptide hormone produced by the corpora lutea of ovaries during pregnancy in many mammalian species, including man. Relaxin widens the pubic bone and facilitates labor, it also softens the cervix (cervical ripening), and relaxes the uterine musculature. However, its significance may reach much further. Relaxin affects collagen metabolism, inhibiting collagen synthesis and enhancing its breakdown by increasing matrix metalloproteinases. It also enhances angiogenesis and is a potent renal vasodilator.

Kit Components

Catalog Number Description Quantity
EK1230-CAP Anti-Human RLN1 Pre-coated 96-well strip microplate 1
EK1230-ST Human RLN1 Standard 2 vials, 10 ng/tube
EK1230-DA Human RLN1 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)078156312625125025005000
O.D.0.0330.0400.0520.0930.1720.4091.0282.108

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Relaxin-1, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 78 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human Relaxin 1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)14481923901337962573
Standard deviation10.9437.67100.3810.542.98118.35
CV (%)7.6%4.6%4.2%7.9%5.4%4.6%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Relaxin-1 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 11441251441331368.015.8%
Sample 281975973468875047.286.3%
Sample 32390222223072378232467.012.8%
*number of samples for each test n=16.

Gene/Protein Information For RLN1 (Source: Uniprot.Org, NCBI)

Gene Name

RLN1

Full Name

Prorelaxin H1

Weight

21.146kDa

Superfamily

insulin family

Alternative Names

bA12D24.3.1; bA12D24.3.2; H1; preprorelaxin H1; prorelaxin H1; relaxin 1 (H1); relaxin 1; relaxin H1; Relaxin1; Relaxin-1; RLN1; RLXH1 RLN1 H1, H1RLX, RLXH1, bA12D24.3.1, bA12D24.3.2 relaxin 1 prorelaxin H1|preprorelaxin H1

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on RLN1, check out the RLN1 Infographic

RLN1 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for RLN1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1230

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human Relaxin 1 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Human Relaxin 1 ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Human Relaxin 1 ELISA Kit PicoKine®

Question

Would you please confirm that the standard of EK1230 is recombinant protein? And please let us know the amino acid sequence of the standard.

Verified customer

Asked: 2022-07-18

Answer

Thank you for your question. The standard of EK1230 is recombinant protein. The amino acid sequence is R162-Cys185 (A) & K26-S53 (B). Contact us freely for any other questions.

Boster Scientific Support

Answered: 2022-07-18

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis Relaxin-1 using the EK1230 Human Relaxin-1 Picokine® ELISA Kit?

T. Evans

Verified customer

Asked: 2020-11-10

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. avoid repetitive freeze-thaw cycles with the stored samples to limit protein degradation.

Boster Scientific Support

Answered: 2020-11-10

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2020-10-15

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2020-10-15

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-07-07

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2020-07-07

Question

Q: how to thaw whole blood sample for Relaxin-1 ELISA after freezing?

Verified Customer

Verified customer

Asked: 2019-07-29

Answer

A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test Relaxin-1 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.

Boster Scientific Support

Answered: 2019-07-29

Question

Q: how are cell lysates prepared for use in Picokine® ELISA kits?

A. Jha

Verified customer

Asked: 2018-11-25

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can effect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2018-11-25

Question

Q: Can Relaxin-1 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-03-05

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-03-05

Question

Q: can you recommend the dilution ratio of serum samples for detection of Relaxin-1 in Human plasma? I am trying to measure a a number of analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2018-03-02

Answer

A: without knowing the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the Relaxin-1 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2018-03-02

Question

Q: if the enzyme conjugated Relaxin-1 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Relaxin-1 antigen?

Verified Customer

Verified customer

Asked: 2016-04-17

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2016-04-17

$499
In stock, 2 left.

Order within 82 hours and 58 minutes to receive by Tue May 21

Get A Quote
In stock
Order Product
EK1230
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.