Mouse NOV/CCN3 ELISA Kit PicoKine®

CCN3 ELISA kit for Mouse

Mouse NOV/CCN3 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Ccn3 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. Cited in 2 publication(s).

Product Info Summary

SKU: EK0834
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse NOV/CCN3 ELISA Kit PicoKine®

View all CCN3 ELISA kits

SKU/Catalog Number

EK0834

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse NOV/CCN3 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Ccn3 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse NOV/CCN3 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0834)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: Q22-I354

Sensitivity

<10 pg/ml

Assay Range

31.2 pg/ml - 2,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK0834 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0834 is reactive to CCN3 in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0834 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CCN3

NOV (nephroblastoma overexpressed), also known as CCN3, is a matricellular protein that in humans is encoded by the NOV gene. The protein encoded by this gene is a small secreted cysteine-rich protein and a member of the CCN family of regulatory proteins. This gene is mapped to 8q24.12. NOV is a potentially useful marker for the diagnosis of adrenal gland diseases, malignant adrenocortical tumors, multiple sclerosis and so on. Moreover, reduced expression of NOV in ACTs may play an important role in the process of childhood ACT tumorigenesis. Though studying, it identified Nov as a regulator of human hematopoietic stem or progenitor cells.

Kit Components

Catalog Number Description Quantity
EK0834-CAP Anti-Mouse CCN3 Pre-coated 96-well strip microplate 1
EK0834-ST Mouse CCN3 Standard 2 vials, 10 ng/tube
EK0834-DA Mouse CCN3 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)031.262.512525050010002000
O.D.0.0950.1480.2090.2750.4720.7691.2181.868

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CCN3, Dilution ratio of 1:50, concentration in serum and plasma is 10-50 ng/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse NOV/CCN3 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)8427799977292970
Standard deviation3.8614.1249.954.6218.9849.47
CV (%)4.6%5.1%%5%6%6.5%5.1%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CCN3 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 184978886884.965.6%
Sample 227725930127627814.955.3%
Sample 39999819999829908.750.8%
*number of samples for each test n=16.

Gene/Protein Information For CCN3 (Source: Uniprot.Org, NCBI)

Gene Name

CCN3

Full Name

CCN family member 3

Weight

39.162kDa

Superfamily

CCN family

Alternative Names

CCN family member 3 CCN3 IBP-9, IGFBP-9, IGFBP9, NOV, NOVh cellular communication network factor 3 CCN family member 3|IGF-binding protein 9|insulin-like growth factor-binding protein 9|nephro blastoma-overexpressed gene protein homolog|nephroblastoma overexpressed|nephroblastoma-overexpressed gene protein homolog|protein NOV homolog

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on CCN3, check out the CCN3 Infographic

CCN3 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for CCN3: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK0834 has been cited in 2 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Mingyue Shen,Xianxiang Chen,Lixin Huang,Qiang Yu,Yi Chen,Jianhua Xie,Sulfated Mesona chinensis Benth polysaccharide enhance the immunomodulatory activities of cyclophosphamide-treated mice,Journal of Functional Foods,Volume 76,2021,104321,ISSN 1756-4646,h
Species: Mouse
EK0834 usage in article: APP:ELISA, SAMPLE:MACROPHAGE CELLS, DILUTION:NA

Huang L,Shen M,Wu T,Yu Y,Yu Q,Chen Y,Xie J.Mesona chinensis Benth polysaccharides protect against oxidative stress and immunosuppression in cyclophosphamide-treated mice via MAPKs signal transduction pathways.Int J Biol Macromol.2020 Jun 1;152:766-774. do
Species: Mesona chinensis, Mouse
EK0834 usage in article: APP:ELISA, SAMPLE:SPLEEN, DILUTION:NA

Have you used Mouse NOV/CCN3 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Mouse NOV/CCN3 ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Mouse NOV/CCN3 ELISA Kit PicoKine®

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2020-12-17

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2020-12-17

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

D. Davis

Verified customer

Asked: 2020-12-13

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer may affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2020-12-13

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring Nov using the EK0834 Mouse Nov Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-11-26

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples to prevent protein degradation.

Boster Scientific Support

Answered: 2020-11-26

Question

Q: if the enzyme conjugated Nov antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Nov antigen?

Verified Customer

Verified customer

Asked: 2018-09-20

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2018-09-20

Question

Q: is it okay to use citrate plasma as samples in Mouse Nov Picokine® ELISA Kit (Catalog # EK0834)?

Verified Customer

Verified customer

Asked: 2018-07-28

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can sequester metal ions from the functional domain of Nov causing degradation of its protein structure. Nov may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the Nov ELISA, treating samples with different anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2018-07-28

Question

Q: Can Nov ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-06-09

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-06-09

Question

Q: can you suggest the dilution ratio of serum samples for detection of Nov in Mouse plasma? I am trying to measure a multiple analytes and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.

C. Allen

Verified customer

Asked: 2016-06-01

Answer

A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the Nov ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2016-06-01

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2016-04-23

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2016-04-23

$499
In stock, 1 left.

Order within 4 hours and 52 minutes to receive by Wed May 15

Get A Quote
In stock
Order Product
EK0834
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.