Mouse Serpin A1 ELISA Kit PicoKine®

Serpina1c ELISA kit for Mouse

Mouse Serpin A1 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Serpina1c in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml .

Product Info Summary

SKU: EK1711
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA).

Product Name

Mouse Serpin A1 ELISA Kit PicoKine®

View all Serpina1c ELISA kits

SKU/Catalog Number

EK1711

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse Serpin A1 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Serpina1c in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml .

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse Serpin A1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1711)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: E25-K413

Sensitivity

<10 pg/ml

Assay Range

1.56 ng/ml - 100 ng/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1711 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1711 is reactive to Serpina1c in Mouse samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA).

Application Guarantee

EK1711 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Serpina1c

SERPINA1 is also known as PI, A1A or AAT. This gene is mapped to 14q32.1. The protein encoded by this gene is secreted and is a serine protease inhibitor whose targets include elastase, plasmin, thrombin, trypsin, chymotrypsin, and plasminogen activator. Defects in this gene can cause emphysema or liver disease. Several transcript variants encoding the same protein have been found for this gene.

Kit Components

Catalog Number Description Quantity
EK1711-CAP Anti-Mouse Serpina1c Pre-coated 96-well strip microplate 1
EK1711-ST Mouse Serpina1c Standard 2 vials, 100 ng/tube
EK1711-DA Mouse Serpina1c Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (ng/ml)01.563.136.2512.52550100
O.D.0.0420.2070.3680.6591.0541.3691.6452.069

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Serpina1c, Dilution ratio of 1:10000, concentration in serum and plasma is 30-160 ug/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse Serpin A1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)287613987372312911141224269
Standard deviation158.18713.31600.9177.57932.05320.18
CV (%)5.5%5.1%4.3%6.1%6.6%7.5%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Serpina1c in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 128762791243826162680168.376.2%
Sample . 21398713721134611439313890344.602.4%%
Sample 337231377943824741965388091857.184.7%
*number of samples for each test n=16.

Gene/Protein Information For Serpina1c (Source: Uniprot.Org, NCBI)

Gene Name

Serpina1c

Full Name

Alpha-1-antitrypsin 1-3

Weight

45.823kDa

Superfamily

serpin family

Alternative Names

Alpha-1-antitrypsin 1-3 Serpina1c|P, Pi3, Pi6, Skalp, Spi, Spi1-3, Spi1-6, Wap3|serine (or cysteine) peptidase inhibitor, clade A, member 1C|alpha-1-antitrypsin 1-3|alpha-1 protease inhibitor 3|alpha-1 protease inhibitor 6|alpha-1-antitrypsin 1-6|apha-1 protease inhibitor 3|pre-elafin|serine (or cysteine) proteinase inhibitor, clade A, member 1c|serine protease inhibitor 1-3|serine protease inhibitor 1-6|serine protease inhibitor A1c|serpin A1c|trappin-2

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Serpina1c, check out the Serpina1c Infographic

Serpina1c infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Serpina1c: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1711

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse Serpin A1 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Mouse Serpin A1 ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Mouse Serpin A1 ELISA Kit PicoKine®

Question

Q: how do I analyze ELISA data? I measured STAT3 level in plasma .

Verified Customer

Verified customer

Asked: 2019-12-29

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2019-12-29

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

L. Surve

Verified customer

Asked: 2019-09-10

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2019-09-10

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-07-07

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2019-07-07

Question

Q: Can STAT3 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-02-09

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-02-09

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

H. Hill

Verified customer

Asked: 2017-07-25

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2017-07-25

Question

Q: can you recommend the dilution ratio of serum samples for detection of STAT3 in Mouse plasma ? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2017-03-18

Answer

A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the STAT3 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2017-03-18

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis STAT3 using the EK1711 Mouse STAT3 Picokine® ELISA Kit?

C. Wright

Verified customer

Asked: 2016-06-10

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to prevent protein degradation.

Boster Scientific Support

Answered: 2016-06-10

Question

Q: What is the optimal O.D. value for STAT3 ELISA kit? I performed your STAT3 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain STAT3 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2016-02-27

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this STAT3 ELISA kit to have sensitivity of 10pg/ml , that means the minimum amount of STAT3 that can be declared/interpreted as positive by the above standard is 10pg/ml .

Boster Scientific Support

Answered: 2016-02-27

$499
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
In stock
Order Product
EK1711
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.