Mouse CHL1/L1CAM-2 ELISA Kit PicoKine®

CHL-1/L1CAM-2 ELISA kit for Mouse

Mouse CHL1/L1CAM-2 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Chl1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.

Product Info Summary

SKU: EK1577
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse CHL1/L1CAM-2 ELISA Kit PicoKine®

View all CHL-1/L1CAM-2 ELISA kits

SKU/Catalog Number

EK1577

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse CHL1/L1CAM-2 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Chl1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse CHL1/L1CAM-2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1577)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: E26-W1083

Sensitivity

<10 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1577 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1577 is reactive to CHL1 in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK1577 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CHL-1/L1CAM-2

Neural cell adhesion molecule L1-like protein also known as close homolog of L1 (CHL1) is a protein that in humans is encoded by the CHL1 gene. This protein is a member of the L1 gene family of neural cell adhesion molecules. By FISH, the CHL1 gene was mapped to chromosome 3p26.1. The protein however has dynamic localisation, meaning that it has not only multiple roles in the cell, but also various locations. This protein may also play a role in the growth of certain cancers.

Kit Components

Catalog Number Description Quantity
EK1577-CAP Anti-Mouse CHL1 Pre-coated 96-well strip microplate 1
EK1577-ST Mouse CHL1 Standard 2 vials, 10 ng/tube
EK1577-DA Mouse CHL1 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512500025000500010000
O.D.0.0030.0840.1440.2680.5220.9451.7192.493

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CHL-1/L1CAM-2, Dilution ratio of 1:5, concentration in serum and plasma is 6-10 ng/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse CHL1/L1CAM-2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)2181822467420717534970
Standard deviation15.04116.6198.2%17.59143.74238.56
CV (%)6.9%6.4%4.2%8.5%8.2%4.8%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CHL-1/L1CAM-2 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 121822324525323414.636.2%
Sample 218221615191117721780107.486%
Sample 346744640483748774757101.72.1%
*number of samples for each test n=16.

Gene/Protein Information For CHL1 (Source: Uniprot.Org, NCBI)

Gene Name

CHL1

Full Name

Neural cell adhesion molecule L1-like protein

Weight

135.071kDa

Superfamily

immunoglobulin superfamily

Alternative Names

CALL; CALLClose homolog of L1; cell adhesion molecule with homology to L1CAM (close homolog of L1); cell adhesion molecule with homology to L1CAM (close homologue of L1); CHL1; CHL-1; FLJ44930; L1CAM-2; L1CAM2L1 cell adhesion molecule 2; MGC132578; neural cell adhesion molecule L1-like protein CHL1 CALL, L1CAM2 cell adhesion molecule L1 like neural cell adhesion molecule L1-like protein|L1 cell adhesion molecule 2|cell adhesion molecule with homology to L1CAM (close homolog of L1)|cell adhesion molecule with homology to L1CAM (close homologue of L1)|close homolog of L1

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on CHL1, check out the CHL1 Infographic

CHL1 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for CHL1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1577

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse CHL1/L1CAM-2 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Mouse CHL1/L1CAM-2 ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

7 Customer Q&As for Mouse CHL1/L1CAM-2 ELISA Kit PicoKine®

Question

Q: Can CHL-1 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2020-07-30

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2020-07-30

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

M. Lewis

Verified customer

Asked: 2019-12-19

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2019-12-19

Question

Q: if the enzyme conjugated CHL-1 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CHL-1 antigen?

W. Parker

Verified customer

Asked: 2018-10-16

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2018-10-16

Question

Q: which procedure should I follow in order to thaw whole blood sample for CHL-1 ELISA after freezing?

P. Harris

Verified customer

Asked: 2018-05-25

Answer

A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CHL-1 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.

Boster Scientific Support

Answered: 2018-05-25

Question

Q: we need your suggestion regarding the dilution ratio of serum samples for detection of CHL-1 in Mouse plasma? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2017-08-19

Answer

A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CHL-1 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2017-08-19

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2016-02-05

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is needed for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2016-02-05

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis CHL-1 using the EK1577 Mouse CHL-1 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2015-06-24

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to prevent protein degradation.

Boster Scientific Support

Answered: 2015-06-24

$750
In stock, 3+ left.

Order within -1 hours and -32 minutes to receive by Wed May 15

Get A Quote
In stock
Order Product
EK1577
$750.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.