Rat SEZ6L ELISA Kit PicoKine®

SEZ6L ELISA kit for Rat

Rat SEZ6L ELISA Kit PicoKine™ (96 Tests). Quantitate Rat Sez6l in cell culture supernatants, serum and plasma (heparin). Sensitivity: 50pg/ml.

Product Info Summary

SKU: EK1832
Size: 96 wells/kit, with removable strips.
Reactive Species: Rat
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin).

Product Name

Rat SEZ6L ELISA Kit PicoKine®

View all SEZ6L ELISA kits

SKU/Catalog Number

EK1832

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Rat SEZ6L ELISA Kit PicoKine™ (96 Tests). Quantitate Rat Sez6l in cell culture supernatants, serum and plasma (heparin). Sensitivity: 50pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Rat SEZ6L ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1832)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: L29-A958

Sensitivity

<50 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1832 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1832 is reactive to SEZ6L in Rat samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin).

Application Guarantee

EK1832 is guaranteed for ELISA in Rat by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of SEZ6L

Seizure 6-like protein is a protein that in humans is encoded by the SEZ6L gene. It is mapped to 12q16.

Kit Components

Catalog Number Description Quantity
EK1832-CAP Anti-Rat SEZ6L Pre-coated 96-well strip microplate 1
EK1832-ST Rat SEZ6L Standard 2 vials, 10 ng/tube
EK1832-DA Rat SEZ6L Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512502500500010000
O.D.0.0520.1640.2230.3160.5520.9381.4132.174

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect SEZ6L, Dilution ratio of 1:1, concentration in serum and plasma is around 1500 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Rat SEZ6L ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)17680741262609414859
Standard deviation8.6234.70169.1715.6054.58335.27
CV (%)4.9%4.3%4.1%6.0%5.8%6.9%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of SEZ6L in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 11761991781901859.335.0%
Sample 280782575874378333.784.3%
Sample 341263875371239283910147.823.7%
*number of samples for each test n=16.

Gene/Protein Information For SEZ6L (Source: Uniprot.Org, NCBI)

Gene Name

SEZ6L

Full Name

Seizure 6-like protein

Weight

111.782kDa

Superfamily

SEZ6 family

Alternative Names

Acig1; AIG1; Aig1L; BSRP-B; seizure related 6 homolog (mouse)-like; seizure related gene 6-like; SEZ6L SEZ6L seizure related 6 homolog like seizure 6-like protein|seizure related gene 6-like

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on SEZ6L, check out the SEZ6L Infographic

SEZ6L infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for SEZ6L: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1832

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Rat SEZ6L ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Rat SEZ6L ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

7 Customer Q&As for Rat SEZ6L ELISA Kit PicoKine®

Question

Q: which procedure should I follow in order to thaw whole blood sample for SEZ6L ELISA after freezing?

Verified Customer

Verified customer

Asked: 2020-10-19

Answer

A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test SEZ6L for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.

Boster Scientific Support

Answered: 2020-10-19

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2020-08-26

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2020-08-26

Question

Q: can you recommend the dilution ratio of serum samples for detection of SEZ6L in Rat serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2020-05-20

Answer

A: without having an understanding the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the SEZ6L ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2020-05-20

Question

Q: Can SEZ6L ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2019-05-02

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2019-05-02

Question

Q: how do I analyze ELISA data? I measured SEZ6L level in serum.

Verified Customer

Verified customer

Asked: 2019-04-16

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2019-04-16

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2018-06-26

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2018-06-26

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement SEZ6L using the EK1832 Rat SEZ6L Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2017-03-21

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples in order to limit protein degradation.

Boster Scientific Support

Answered: 2017-03-21

$750
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
In stock
Order Product
EK1832
$750.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.