Compare fluorescence excitation and emission spectra from 1,476 dye records alongside light sources and optical filters. Add dyes to the chart, explore their measurement conditions, and share your selected spectra or download the graph.
| Quantity | How to interpret it |
|---|---|
| Excitation and emission peaks | Source-reported peak wavelengths, in nanometres (nm). A reported peak can differ slightly from the maximum sampled point on a curve. |
| Normalized intensity | Each available curve is scaled to its own maximum. Curve heights compare spectral shape; they do not establish absolute brightness or detection efficiency. |
| Stokes shift | The difference between emission and excitation peak wavelengths. Where the catalogue does not report a shift, the search filter can use the difference between the two available peaks. |
| Measurement conditions | Solvent, pH, ion concentration, and other reported conditions can change a spectrum. Distinct conditions remain separate in the viewer. |
| Laser and filter overlays | Laser lines and idealized filter passbands help compare wavelength ranges. Actual transmission curves and instrument performance should be checked against the manufacturer's specifications. |
The viewer uses a CIE-based colour approximation for visible wavelengths from 380–780 nm. Beyond 780 nm, the red-brown palette is a display convention for near-infrared light, not a colour visible to the human eye. Grey can indicate ultraviolet or unavailable wavelength information.
No. The displayed curves are independently normalized. Brightness also depends on properties such as extinction coefficient and quantum yield, as well as illumination, sample conditions, and detector response.
Some source records do not include both excitation and emission measurements. The viewer marks missing curves instead of inventing data. Other records include multiple measurement conditions, which can be selected separately.
Yes. Copy Link retains the selected dyes, measurement conditions, exact laser and filter settings, hidden curves, fill setting, line width, and manual wavelength range. The recipient opens this page on bosterbio.com.
The chart supports spectral comparison and selection of candidate dyes and optics. It does not replace experimental controls, measured filter transmission, instrument calibration, or validation under your assay conditions.
The current catalogue contains 1,476 dye records, 65 light-source configurations, and 65 filter-source configurations. The reference comparison was checked on November 2, 2026 against the AAT Bioquest spectrum database. Three retained legacy HiLyte Plus records are identified in the tool. Missing measurements and unusual source-reported values remain explicitly represented.