Human ckmm ELISA Kit PicoKine®

Creatine Kinase, Muscle/CKMM ELISA kit for Human

Human ckmm ELISA Kit PicoKine™ (96 Tests). Quantitate Human CKM in cell culture supernatants, serum and plasma (heparin, EDTA, citrate ). Sensitivity: 0.05mU/ml.

Product Info Summary

SKU: EK1751
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA, citrate ).

Product Name

Human ckmm ELISA Kit PicoKine®

View all Creatine Kinase, Muscle/CKMM ELISA kits

SKU/Catalog Number

EK1751

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human ckmm ELISA Kit PicoKine™ (96 Tests). Quantitate Human CKM in cell culture supernatants, serum and plasma (heparin, EDTA, citrate ). Sensitivity: 0.05mU/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human ckmm ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1751)

Clonality of Antibodies

See Datasheet for details

Immunogen

natural protein

Sensitivity

<0.05 mU/ml

Assay Range

0.15mU/ml - 10mU/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1751 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1751 is reactive to CKM in Human samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA, citrate ).

Application Guarantee

EK1751 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Creatine Kinase, Muscle/CKMM

Creatine kinase, muscle also known as CKM is a creatine kinase that in humans is encoded by the CKM gene. This gene is mapped to 19q13.32. The protein encoded by this gene is a cytoplasmic enzyme involved in energy homeostasis and is an important serum marker for myocardial infarction. The encoded protein reversibly catalyzes the transfer of phosphate between ATP and various phosphogens such as creatine phosphate. It acts as a homodimer in striated muscle as well as in other tissues, and as a heterodimer with a similar brain isozyme in heart. The encoded protein is a member of the ATP:guanido phosphotransferase protein family.

Kit Components

Catalog Number Description Quantity
EK1751-CAP Anti-Human CKM Pre-coated 96-well strip microplate 1
EK1751-ST Human CKM Standard 2 vials, 10 mU/tube
EK1751-DA Human CKM Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (mU/ml)00.150.310.621.252.5510
O.D.0.0210.0400.0680.1090.1830.3840.8721.829

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Creatine Kinase, Muscle/CKMM, Dilution ratio of 1:20, concentration in serum and plasma is 30-50mU/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human ckmm ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (mU/ml)2331369363624214214520
Standard deviation9.7788.99147.513.3196.6329.96
CV (%)4.2%6.5%4.8%5.5%6.8%7.3%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Creatine Kinase, Muscle/CKMM in ELISA kits from four different production batches/lots.

LotsLot 1 (mU/ml)Lot 2 (mU/ml)Lot 3 (mU/ml)Lot 4 (mU/ml)Mean (mU/ml)Standard DeviationCV (%)
Sample 12332332522342388.093.3%
Sample 21369155916021564152390.735.9%
Sample 336363701377742933851259.596.7%
*number of samples for each test n=16.

Gene/Protein Information For CKM (Source: Uniprot.Org, NCBI)

Gene Name

CKM

Full Name

Creatine kinase M-type

Weight

43.101kDa

Superfamily

ATP:guanido phosphotransferase family

Alternative Names

CKM; CKMM; CKMMcreatine kinase M-type; Creatine kinase M chain; Creatine Kinase MM; creatine kinase, muscle; creatine kinase-M; EC 2.7.3; EC 2.7.3.2; M-CK CKM CKMM, CPK-M, M-CK creatine kinase, M-type creatine kinase M-type|creatine kinase M chain|creatine kinase, muscle|creatine phosphokinase M-type

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on CKM, check out the CKM Infographic

CKM infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for CKM: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1751

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human ckmm ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Human ckmm ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Human ckmm ELISA Kit PicoKine®

Question

Q: Can CKMM ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2020-03-04

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2020-03-04

Question

Q: how are cell lysates prepared for use in Picokine® ELISA kits?

M. Thomas

Verified customer

Asked: 2019-09-25

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer may affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2019-09-25

Question

Q: What is the optimal O.D. value for CKMM ELISA kit? I used your CKMM ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain CKMM even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-05-12

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CKMM ELISA kit to have sensitivity of 0.05mU/ml, that means the minimum amount of CKMM that can be declared/interpreted as positive by the above standard is 0.05mU/ml.

Boster Scientific Support

Answered: 2019-05-12

Question

Q: can I use citrate plasma as samples in Human CKMM Picokine® ELISA Kit (Catalog # EK1751)?

P. Banerjee

Verified customer

Asked: 2019-01-09

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can sequester metal ions from the functional domain of CKMM causing degradation of its protein structure. CKMM may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the CKMM ELISA, treating samples with a number of anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2019-01-09

Question

Q: how to analyze ELISA data? I measured CKMM level in serum.

Verified Customer

Verified customer

Asked: 2018-10-22

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2018-10-22

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement CKMM using the EK1751 Human CKMM Picokine® ELISA Kit?

S. Carter

Verified customer

Asked: 2018-01-04

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to prevent protein degradation.

Boster Scientific Support

Answered: 2018-01-04

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2016-09-25

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2016-09-25

Question

Q: we need your recommendation regarding the dilution ratio of serum samples for detection of CKMM in Human serum? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.

C. Bhatt

Verified customer

Asked: 2016-07-15

Answer

A: without having an understanding the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CKMM ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2016-07-15

$499
In stock, 1 left.

Order within 2 hours and 13 minutes to receive by Wed May 22

Get A Quote
In stock
Order Product
EK1751
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.