Human IL-17RC ELISA Kit PicoKine®

IL-17RC ELISA kit for Human

Human IL-17RC ELISA Kit PicoKine™ (96 Tests). Quantitate Human IL17RC in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml.

Product Info Summary

SKU: EK0984
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Human IL-17RC ELISA Kit PicoKine®

View all IL-17RC ELISA kits

SKU/Catalog Number

EK0984

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human IL-17RC ELISA Kit PicoKine™ (96 Tests). Quantitate Human IL17RC in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human IL-17RC ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0984)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: L21-A454

Sensitivity

<15 pg/ml

Assay Range

250 pg/ml - 16000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK0984 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0984 is reactive to IL17RC in Human samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0984 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of IL-17RC

Interleukin-17 receptor C is a protein that in humans is encoded by the IL17RC gene. By genomic sequence analysis, IL17RC gene was mapped to chromosome 3p25.3-p24.1. This gene encodes a single-pass transmembrane protein that shares limited similarity with the interleukin-17 receptor. Multiple alternatively spliced transcript variants encoding different isoforms have been detected for this gene, but the full-length nature of only three have been determined to date. The biologic activity of IL-17 is dependent on a complex composed of IL-17RA and IL-17RC, suggesting a new paradigm for understanding the interactions between the expanded family of IL-17 ligands and their receptors.

Kit Components

Catalog Number Description Quantity
EK0984-CAP Anti-Human IL17RC Pre-coated 96-well strip microplate 1
EK0984-ST Human IL17RC Standard 2 vials, 20 ng/tube
EK0984-DA Human IL17RC Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)0250500100020004000800016000
O.D.0.0620.1460.2320.3830.6511.0831.6852.178

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect IL-17RC, Dilution ratio of 1:1, concentration in serum is less than the lowest standard, 250 pg/ml..

Some articles we found to cite concentrations of IL-17RC in samples: 24885153 (Pubmed IDs).

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human IL-17RC ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3432996779136030537459
Standard deviation24.69224.7420.7132.76267.51499.75
CV (%)7.2%7.5%5.4%9.1%8.7%6.7%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of IL-17RC in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 134337938635336517.784.8%
Sample 229963084267628112891158.825.4%
Sample 377917695844083968080339.554.2%
*number of samples for each test n=16.

Gene/Protein Information For IL17RC (Source: Uniprot.Org, NCBI)

Gene Name

IL17RC

Full Name

Interleukin-17 receptor C

Weight

86.24kDa

Alternative Names

FLJ95963; FLJ96005; IL-17 RC; IL-17 receptor C; IL-17 RL; IL17F receptor; IL17RC; IL-17RC; IL17Rhom; IL17RL; IL-17RL; IL17-RL; interleukin 17 receptor C; interleukin-17 receptor C; Interleukin-17 receptor homolog; Interleukin-17 receptor-like protein; MGC10763; zcytoR14 IL17RC CANDF9, IL17-RL, IL17RL interleukin 17 receptor C interleukin-17 receptor C|IL-17 receptor C|IL-17RL|IL17F receptor|IL17Rhom|interleukin-17 receptor homolog|interleukin-17 receptor-like protein|zcytoR14

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on IL17RC, check out the IL17RC Infographic

IL17RC infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for IL17RC: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK0984

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human IL-17RC ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Human IL-17RC ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Human IL-17RC ELISA Kit PicoKine®

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement IL-17RC using the EK0984 Human IL-17RC Picokine® ELISA Kit?

J. Campbell

Verified customer

Asked: 2020-07-07

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample on-stat collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to avoid protein degradation.

Boster Scientific Support

Answered: 2020-07-07

Question

Q: can you recommend the dilution ratio of serum samples for detection of IL-17RC in Human plasma? I am trying to measure a a number of analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2020-07-02

Answer

A: unable to know the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the IL-17RC ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2020-07-02

Question

Q: What is the optimal O.D. value for IL-17RC ELISA kit? I used your IL-17RC ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain IL-17RC even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-10-18

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this IL-17RC ELISA kit to have sensitivity of 15pg/ml, that means the minimum amount of IL-17RC that can be declared/interpreted as positive by the above standard is 15pg/ml.

Boster Scientific Support

Answered: 2019-10-18

Question

Q: is it okay to use citrate plasma as samples in Human IL-17RC Picokine® ELISA Kit (Catalog # EK0984)?

Verified Customer

Verified customer

Asked: 2019-09-25

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can sequester metal ions from the functional domain of IL-17RC causing degradation of its protein structure. IL-17RC may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the IL-17RC ELISA, treating samples with a number of anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2019-09-25

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

D. Hall

Verified customer

Asked: 2019-01-01

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2019-01-01

Question

Q: Can IL-17RC ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

M. Johnson

Verified customer

Asked: 2018-10-14

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is a must. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-10-14

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

E. Clark

Verified customer

Asked: 2018-04-29

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-04-29

Question

Q: how are cell lysates prepared for use in Picokine® ELISA kits?

P. Adams

Verified customer

Asked: 2015-08-12

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can have an affect on immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2015-08-12

$499
In stock, 2 left.

Order within 15 hours and 5 minutes to receive by Fri May 17

Get A Quote
In stock
Order Product
EK0984
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.