Product Info Summary
| SKU: | EK2321 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Human |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, serum, plasma(heparin, EDTA) |
Product info
Product Name
Human LAIR2 ELISA Kit PicoKine®
SKU/Catalog Number
EK2321
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human LAIR2 ELISA Kit PicoKine® (96 Tests). Quantitate Human LAIR2 in cell culture supernatants, serum, plasma (heparin, EDTA). Sensitivity: 2pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human LAIR2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK2321)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: Gln22-Pro152
Capture/Detection Antibodies
polyclonal antibody from goat|polyclonal antibody from goat
Sensitivity
<2 pg/mL
Assay Range
7.8-500 pg/mL
Standard Dilution Instructions

See datasheet of EK2321 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK2321 is reactive to LAIR2 in Human samples
Validated Sample Types
cell culture supernatants, serum, plasma(heparin, EDTA)
Application Guarantee
EK2321 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of LAIR2
Leukocyte-associated immunoglobulin-like receptor 2 is a protein that in humans is encoded by the LAIR2 gene. It was identified by its similarity to leukocyte-associated immunoglobulin-like receptor 1, a membrane-bound receptor that modulates innate immune response. The protein encoded by this locus is a soluble receptor that may play roles in both inhibition of collagen-induced platelet aggregation and vessel formation during placental implantation. This gene maps to a region of 19q13.4, termed the leukocyte receptor cluster, which contains 29 genes in the immunoglobulin superfamily. Alternatively spliced transcript variants have been described for this gene.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK2321-CAP | Anti-Human LAIR2 Pre-coated 96-well strip microplate | 1 |
| EK2321-ST | Human LAIR2 Standard | 2 vials, 10 ng/tube |
| EK2321-DA | Human LAIR2 Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 7.8 | 15.6 | 31.2 | 62.4 | 125 | 250 | 500 |
| O.D. | 0.05 | 0.099 | 0.171 | 0.319 | 0.602 | 1.034 | 1.63 | 2.057 |
Data Example Images
Click image to see more details
Human LAIR2 PicoKine ELISA Kit standard curve
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human LAIR2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 12 | 56 | 230 | 15 | 35 | 222 |
| Standard deviation | 0.93 | 3.24 | 13.04 | 0.77 | 1.31 | 17.34 |
| CV (%) | 7.7% | 5.8% | 5.7% | 5.1% | 3.7% | 7.8% |
Specific Publications For Human LAIR2 ELISA Kit PicoKine® (EK2321)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Human LAIR2 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question