Product Info Summary
| SKU: | EK0897 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Human |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, serum, plasma (heparin, EDTA, citrate) and urine. |
Product info
Product Name
Human PLAT/TPA ELISA Kit PicoKine®
SKU/Catalog Number
EK0897
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human PLAT/TPA ELISA Kit PicoKine® (96 Tests). Quantitate Human PLAT in cell culture supernatants, serum, plasma (heparin, EDTA, citrate) and urine. Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human PLAT/TPA ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0897)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: CHO; Immunogen sequence: M1-P562
Sensitivity
<10 pg/ml
Assay Range
31.2 pg/ml - 2,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0897 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0897 is reactive to PLAT in Human samples
Validated Sample Types
cell culture supernatants, serum, plasma (heparin, EDTA, citrate) and urine.
Application Guarantee
EK0897 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of PLAT
Plasminogen activator, tissue, also called PLAT or TPA is a serine protease. This gene encodes tissue-type plasminogen activator, a secreted serine protease which converts the proenzyme plasminogen to plasmin, a fibrinolytic enzyme. Tissue-type plasminogen activator is synthesized as a single chain which is cleaved by plasmin to a two chain disulfide linked protein. This gene was mapped to 8p11.21. This enzyme plays a role in cell migration and tissue remodeling. Increased enzymatic activity causes hyperfibrinolysis, which manifests as excessive bleeding; decreased activity leads to hypofibrinolysis which can result in thrombosis or embolism.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0897-CAP | Anti-Human PLAT Pre-coated 96-well strip microplate | 1 |
| EK0897-ST | Human PLAT Standard | 2 vials, 10 ng/tube |
| EK0897-DA | Human PLAT Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 | 2000 |
| O.D. | 0.033 | 0.123 | 0.198 | 0.336 | 0.554 | 1.018 | 1.753 | 2.842 |
Data Example Images
Click image to see more details
Human PLAT/TPA PicoKine ELISA Kit standard curve
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human PLAT/TPA ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 84 | 237 | 975 | 81 | 229 | 878 |
| Standard deviation | 5.37 | 15.4 | 43.87 | 5.58 | 17.63 | 43.02 |
| CV (%) | 6.4% | 6.5% | 4.5% | 6.9% | 7.7% | 4.9% |
Specific Publications For Human PLAT/TPA ELISA Kit PicoKine® (EK0897)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Human PLAT/TPA ELISA Kit PicoKine®
Submit your question