Mouse ALK-1/ACVRL1 ELISA Kit PicoKine®

ALK-1 ELISA kit for Mouse

Mouse ALK-1/ACVRL1 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Acvrl1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml.

Product Info Summary

SKU: EK1519
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse ALK-1/ACVRL1 ELISA Kit PicoKine®

View all ALK-1 ELISA kits

SKU/Catalog Number

EK1519

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse ALK-1/ACVRL1 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Acvrl1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse ALK-1/ACVRL1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1519)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: D23-P119

Sensitivity

<15 pg/ml

Assay Range

46.9 pg/ml - 3,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1519 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1519 is reactive to ACVRL1 in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK1519 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of ALK-1

Serine/threonine-protein kinase receptor R3 is an enzyme that in humans is encoded by the ACVRL1 gene. It is also known as activin receptor-like kinase 1, or ALK1. This gene encodes a type I cell-surface receptor for the TGF-beta superfamily of ligands. It shares with other type I receptors a high degree of similarity in serine-threonine kinase subdomains, a glycine- and serine-rich region (called the GS domain) preceding the kinase domain, and a short C-terminal tail. The encoded protein shares similar domain structures with other closely related ALK or activin receptor-like kinase proteins that form a subfamily of receptor serine/threonine kinases. Mutations in this gene are associated with hemorrhagic telangiectasia type 2, also known as Rendu-Osler-Weber syndrome 2.

Kit Components

Catalog Number Description Quantity
EK1519-CAP Anti-Mouse ACVRL1 Pre-coated 96-well strip microplate 1
EK1519-ST Mouse ACVRL1 Standard 2 vials, 10 ng/tube
EK1519-DA Mouse ACVRL1 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)046.993.8187.537575015003000
O.D.0.0320.0600.1380.2390.5381.0451.8952.280

Data Example Images

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse ALK-1/ACVRL1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)923381289843191165
Standard deviation6.823.66101.836.6327.4393.2
CV (%)7.4%7%7.9%7.9%8.6%8%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of ALK-1 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 192929682905.175.7%
Sample 233831135835934119.55.7%
Sample 31289145813781338136561.884.5%
*number of samples for each test n=16.

Gene/Protein Information For ACVRL1 (Source: Uniprot.Org, NCBI)

Gene Name

ACVRL1

Full Name

Serine/threonine-protein kinase receptor R3

Weight

56.124kDa

Superfamily

protein kinase superfamily

Alternative Names

activin A receptor type II-like 1; activin A receptor, type II-like kinase 1; Activin receptor-like kinase 1; ACVRL1; ACVRLK1ORW2; ALK1; ALK-1; ALK1TGF-B superfamily receptor type I; EC 2.7.11; HHT; HHT2EC 2.7.11.30; serine/threonine-protein kinase receptor R3; SKR3; TSR-I ACVRL1 ACVRLK1, ALK-1, ALK1, HHT, HHT2, ORW2, SKR3, TSR-I activin A receptor like type 1 serine/threonine-protein kinase receptor R3|TGF-B superfamily receptor type I|activin A receptor type II-like 1|activin A receptor type IL|activin A receptor, type II-like kinase 1

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on ACVRL1, check out the ACVRL1 Infographic

ACVRL1 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for ACVRL1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1519

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse ALK-1/ACVRL1 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Mouse ALK-1/ACVRL1 ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Mouse ALK-1/ACVRL1 ELISA Kit PicoKine®

Question

Q: is it okay to use citrate plasma as samples in Mouse ALK-1 Picokine® ELISA Kit (Catalog # EK1519)?

Verified Customer

Verified customer

Asked: 2020-09-20

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can sequester metal ions from the functional domain of ALK-1 causing degradation of its protein structure. ALK-1 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the ALK-1 ELISA, treating samples with different anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2020-09-20

Question

Q: can you recommend the dilution ratio of serum samples for detection of ALK-1 in Mouse cell lysates? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2020-09-18

Answer

A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the ALK-1 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2020-09-18

Question

Q: What is the optimal O.D. value for ALK-1 ELISA kit? I performed your ALK-1 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain ALK-1 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-12-19

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the above example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this ALK-1 ELISA kit to have sensitivity of 15pg/ml, that means the minimum amount of ALK-1 that can be declared/interpreted as positive by the above standard is 15pg/ml.

Boster Scientific Support

Answered: 2019-12-19

Question

Q: if the enzyme conjugated ALK-1 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the ALK-1 antigen?

T. Varadkar

Verified customer

Asked: 2019-10-09

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2019-10-09

Question

Q: how to analyze ELISA data? I have performed ALK-1 level in cell lysates.

Verified Customer

Verified customer

Asked: 2018-10-30

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2018-10-30

Question

Q: Can ALK-1 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-07-15

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-07-15

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2018-05-29

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2018-05-29

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2017-06-13

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2017-06-13

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

S. Zhao

Verified customer

Asked: 2014-04-25

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2014-04-25

$499
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
In stock
Order Product
EK1519
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.