Mouse BMP-10 ELISA Kit PicoKine®

BMP-10 ELISA kit for Mouse

Mouse BMP-10 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Bmp10 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate ). Sensitivity: 10pg/ml.

Product Info Summary

SKU: EK1809
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA, citrate ).

Product Name

Mouse BMP-10 ELISA Kit PicoKine®

View all BMP-10 ELISA kits

SKU/Catalog Number

EK1809

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse BMP-10 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Bmp10 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate ). Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse BMP-10 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1809)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: N314-R421

Sensitivity

<10 pg/ml

Assay Range

15.6 pg/ml - 1,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1809 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1809 is reactive to Bmp10 in Mouse samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA, citrate ).

Application Guarantee

EK1809 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of BMP-10

Bone morphogenetic proteins (BMPs) constitute a subfamily within the TGF-β superfamily of structurally related signaling proteins. This gene is mapped to 6; 6 D1. Members of this superfamily are widely distributed throughout the body and are involved in diverse physiological processes during both pre- and postnatal life.  BMP-10 plays a crucial role in the development of the embryonic heart by acting to stimulate and maintain cardiomyocyte proliferation.  It can signal through various receptor complexes usually containing BMPR-1A, BMPR-1B, ALK1, ALK3, or ALK6. The interaction of BMP-10 with its specific receptors can induce signaling initiated by the phosphorylation of SMAD transcription factors, including SMAD1, SMAD5, or SMAD8, but can also induce SMAD independent processes.  BMP-10 is structurally related to BMP-9, and both can inhibit endothelial cell proliferation and migration.  Recombinant human BMP-10 is a 24.4 kDa homodimeric disulfide-linked protein consisting of two 108 amino acid subunits, which correspond to amino acid residues 317 to 424 of the full-length BMP-10 precursor.

Kit Components

Catalog Number Description Quantity
EK1809-CAP Anti-Mouse Bmp10 Pre-coated 96-well strip microplate 1
EK1809-ST Mouse Bmp10 Standard 2 vials, 10 ng/tube
EK1809-DA Mouse Bmp10 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015.631.262.51252505001000
O.D.0.0030.0410.0850.1580.3280.5911.1521.943

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect BMP-10, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 15.6 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse BMP-10 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)2921144431226487
Standard deviation1.199.527.531.7113.137.01
CV (%)4.1%4.5%6.2%5.5%5.8%7.6%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of BMP-10 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 129293229291.294.4%
Sample 22112001862072019.514.7%
Sample 344446543050546128.296.1%
*number of samples for each test n=16.

Gene/Protein Information For Bmp10 (Source: Uniprot.Org, NCBI)

Gene Name

Bmp10

Full Name

Bone morphogenetic protein 10

Weight

47.888kDa

Superfamily

TGF-beta family

Alternative Names

BMP10; BMP-10; bone morphogenetic protein 10; MGC126783 Bmp10|b2b2711C, b2b2711Clo|bone morphogenetic protein 10|bone morphogenetic protein 10|BMP-10

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Bmp10, check out the Bmp10 Infographic

Bmp10 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Bmp10: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1809

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse BMP-10 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Mouse BMP-10 ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

5 Customer Q&As for Mouse BMP-10 ELISA Kit PicoKine®

Question

Q: can I use citrate plasma as samples in Mouse BMP-10 Picokine® ELISA Kit (Catalog # EK1809)?

Verified Customer

Verified customer

Asked: 2019-07-13

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can attach metal ions from the functional domain of BMP-10 causing degradation of its protein structure. BMP-10 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the BMP-10 ELISA, treating samples with different anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2019-07-13

Question

Q: if the enzyme conjugated BMP-10 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the BMP-10 antigen?

Verified Customer

Verified customer

Asked: 2019-06-22

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2019-06-22

Question

Q: Can BMP-10 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

D. Varadkar

Verified customer

Asked: 2019-05-27

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is needed. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2019-05-27

Question

Q: What is the optimal O.D. value for BMP-10 ELISA kit? I used your BMP-10 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain BMP-10 even though the O.D. values are not very high?

E. Singh

Verified customer

Asked: 2019-04-01

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your protocol, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this BMP-10 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of BMP-10 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2019-04-01

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2016-01-21

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2016-01-21

$750
In stock, 1 left.

Order within 13 hours and 5 minutes to receive by Fri May 17

Get A Quote
In stock
Order Product
EK1809
$750.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.