Product Info Summary
| SKU: | EK2070 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Mouse |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA, citrate). |
Product info
Product Name
Mouse GFRA1 ELISA Kit PicoKine®
SKU/Catalog Number
EK2070
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse GFRA1 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Gfra1 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse GFRA1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK2070)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: D25-S430
Capture/Detection Antibodies
The capture antibody is monoclonal antibody from rat and the detection antibody is polyclonal antibody from goat.
Sensitivity
<10 pg/ml
Assay Range
31.2 pg/ml - 2,000 pg/ml
Standard Dilution Instructions

See datasheet of EK2070 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK2070 is reactive to Gfra1 in Mouse samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA, citrate).
Application Guarantee
EK2070 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Gfra1
GDNF family receptor alpha-1 (GFRα1), also known as the GDNF receptor, is a protein that in humans is encoded by the GFRA1 gene. It is mapped to 19 D2; 19 54.18 cM. Glial cell line-derived neurotrophic factor (GDNF) and neurturin (NTN) are two structurally related, potent neurotrophic factors that play key roles in the control of neuron survival and differentiation. The protein encoded by this gene is a member of the GDNF receptor family. It is a glycosylphosphatidylinositol (GPI)-linked cell surface receptor for both GDNF and NTN, and mediates activation of the RET tyrosine kinase receptor. This gene is a candidate gene for Hirschsprung disease. Two alternatively spliced transcript variants encoding different isoforms have been described for this gene.GDNF family receptor alpha 1 has been shown to interact with GDNF and RET proto-oncogene.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK2070-CAP | Anti-Mouse Gfra1 Pre-coated 96-well strip microplate | 1 |
| EK2070-ST | Mouse Gfra1 Standard | 2 vials, 10 ng/tube |
| EK2070-DA | Mouse Gfra1 Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 | 2000 |
| O.D. | 0.07 | 0.143 | 0.197 | 0.292 | 0.464 | 0.793 | 1.212 | 2.025 |
Data Example Images
Click image to see more details
Mouse GFRA1 PicoKine ELISA Kit Standard Curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Gfra1, Dilution ratio of 1:1, concentration in serum and plasma is around 227 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse GFRA1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 78 | 249 | 857 | 81 | 254 | 955 |
| Standard deviation | 3.20 | 11.45 | 45.42 | 4.46 | 17.02 | 71.63 |
| CV (%) | 4.1% | 4.6% | 5.3% | 5.5% | 6.7% | 7.5% |
Specific Publications For Mouse GFRA1 ELISA Kit PicoKine® (EK2070)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Mouse GFRA1 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
6 Customer Q&As for Mouse GFRA1 ELISA Kit PicoKine®
Question
Q: if the enzyme conjugated GFR alpha-1 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the GFR alpha-1 antigen?
Verified Customer
Verified customer
Asked: 2019-12-26
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2019-12-26
Question
Q: how to proceed with the analysis of ELISA data? I have obtained GFR alpha-1 level in serum.
Verified Customer
Verified customer
Asked: 2019-12-08
Answer
A: please read this article on ELISA data analysis. bosterbio.com/elisa-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/elisa-data-analysis-online
Boster Scientific Support
Answered: 2019-12-08
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification GFR alpha-1 using the EK2070 Mouse GFR alpha-1 Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2019-04-28
Answer
A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample on-stat collection when possible, or aliquot into single use volumes and store samples frozen. avoid repetitive freeze-thaw cycles with the stored samples to prevent protein degradation.
Boster Scientific Support
Answered: 2019-04-28
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
D. Walker
Verified customer
Asked: 2019-02-18
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2019-02-18
Question
Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2019-01-01
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can have an affect on immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2019-01-01
Question
Q: how much samples can be assayed in a Picokine® ELISA Kit?
W. Dayal
Verified customer
Asked: 2018-10-04
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2018-10-04