Product Info Summary
| SKU: | EK0422 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Mouse |
| Application: | ELISA |
| Sample Types: | cell culture supernatants and serum. |
Product info
Product Name
Mouse IL-12(p70) ELISA Kit PicoKine®
SKU/Catalog Number
EK0422
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse IL-12 (p70) ELISA Kit PicoKine® (96 Tests). Quantitate Mouse IL-12(p70) in cell culture supernatants and serum. Sensitivity: 1.5pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse IL-12(p70) ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0422)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: (M23-S335)+ (R23-A215)
Capture/Detection Antibodies
The capture antibody is monoclonal antibody from rat and the detection antibody is polyclonal antibody from goat.
Sensitivity
<1.5 pg/ml
Assay Range
15.6 pg/ml - 1,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0422 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0422 is reactive to Il12a in Mouse samples
Validated Sample Types
cell culture supernatants and serum.
Application Guarantee
EK0422 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Il12a
Interleukin (IL)-12 is a 70-KDa cytokine comprised of two disulfide-linked proteins (p35 and p40) and is essential for the initiation of effective immune response. And the IL-12p70 is a heterodimer of p35 and p40 subunits; it is an important cytokine secreted by antigen-presenting cells in response to antigenic stimulation. Gene expression analysis of the IL-12 cytokine family subunits revealed that both strains induced high levels of p40 (protein chain communal to IL-12 p70 and IL-23) as well as p19, a subunit of IL-23. Conversely only ACT- 18HS19 infection induced consistent transcription of IL-12 p35, a subunit of IL-12 p70. The standard product used in this kit is recombinant mouse IL-12 p70 comprising of a 193 amino acids p35 chain and a 313 amino acids p40 chain connected by a disulfide bond.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0422-CAP | Anti-Mouse Il12a Pre-coated 96-well strip microplate | 1 |
| EK0422-ST | Mouse Il12a Standard | 2 vials, 10 ng/tube |
| EK0422-DA | Mouse Il12a Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 15.6 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 |
| O.D. | 0.003 | 0.056 | 0.097 | 0.203 | 0.388 | 0.691 | 1.286 | 1.906 |
Data Example Images
Click image to see more details
Mouse IL-12(p70) PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Il12a, Dilution ratio of 1:1, concentration in serum is 2-40 pg/ml..
Some articles we found to cite concentrations of Il12a in samples: 17430656 (Pubmed IDs).
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse IL-12(p70) ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 37 | 150 | 410 | 33 | 147 | 442 |
| Standard deviation | 2.18 | 9.15 | 30.75 | 2.44 | 8.96 | 38.45 |
| CV (%) | 7.5% | 6.1% | 7.5% | 7.4% | 6.1% | 8.7% |
Specific Publications For Mouse IL-12(p70) ELISA Kit PicoKine® (EK0422)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
1 Reviews For Mouse IL-12(p70) ELISA Kit PicoKine®
Good Mouse IL-12 ELISA Kit--Daisy Dai University of Miami Surgery Lab Director / Manager
Excellent

Source: Biocompare.com
| SKU | EK0422 |
|---|---|
| Application | ELISA |
| Starting Material | Crispr MEK and STAT3 KO CAFs |
| Tips | This kit doesn't provide PC |
"We investigate how alterations in RAS and STAT3 signaling pathways affect the tumor stroma and immune microenvironment in pancreatic cancer. This kit was used to detect the IL-12 level in CM from Crispr MEK and STAT3 KO CAFs. The whole process was about 7 hours including sample preparation."
Daisy Dai
Verified customer
Submitted 2020-07-30
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
4 Customer Q&As for Mouse IL-12(p70) ELISA Kit PicoKine®
Question
Q: how to thaw whole blood sample for IL12A ELISA after freezing?
Verified Customer
Verified customer
Asked: 2020-09-11
Answer
A: we do not recommend freezing and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test IL12A for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.
Boster Scientific Support
Answered: 2020-09-11
Question
Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2019-05-21
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can have an affect on immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2019-05-21
Question
Q: Can IL12A ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2018-06-25
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2018-06-25
Question
Q: can you suggest the dilution ratio of serum samples for detection of IL12A in Mouse serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.
Verified Customer
Verified customer
Asked: 2017-04-03
Answer
A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the IL12A ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/elisa-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2017-04-03