Product Info Summary
| SKU: | EK0866 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Mouse |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, serum and plasma (heparin). |
Product info
Product Name
Mouse IL-23 ELISA Kit PicoKine®
SKU/Catalog Number
EK0866
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse IL-23 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Il23a in cell culture supernatants, serum and plasma (heparin). Sensitivity: 2pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse IL-23 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0866)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: (M23-S335) + (L20-A196)
Sensitivity
<2 pg/ml
Assay Range
31.2 pg/ml - 2,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0866 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0866 is reactive to Il23a in Mouse samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin).
Application Guarantee
EK0866 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Il23a
Interleukin-23 subunit alpha (IL-23) is a protein that in humans is encoded by the IL23A gene. IL-23 is a heterodimeric cytokine consisting of two subunits, one called p40, which is shared with another cytokine, IL-12, and another called p19 (the IL-23 alpha subunit). IL-23 is an important part of the inflammatory response against infection. It promotes upregulation of the matrix metalloprotease MMP9, increases angiogenesis and reduces CD8+ T-cell infiltration. Recently, IL-23 has been implicated in the development of cancerous tumors. he International Radiation Hybrid Mapping Consortium mapped the p19 gene to chromosome 12 (stSG47812).
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0866-CAP | Anti-Mouse Il23a Pre-coated 96-well strip microplate | 1 |
| EK0866-ST | Mouse Il23a Standard | 2 vials, 10 ng/tube |
| EK0866-DA | Mouse Il23a Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 | 2000 |
| O.D. | 0.043 | 0.115 | 0.175 | 0.268 | 0.446 | 0.823 | 1.418 | 2.273 |
Data Example Images
Click image to see more details
Mouse IL-23 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Il23a, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 31.2 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse IL-23 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 93 | 278 | 780 | 85 | 279 | 762 |
| Standard deviation | 4.09 | 13.9 | 34.32 | 4.4%7 | 19.25 | 38.86 |
| CV (%) | 4.4% | 5% | 4.4% | 6.2% | 6.9% | 5.1% |
Specific Publications For Mouse IL-23 ELISA Kit PicoKine® (EK0866)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Mouse IL-23 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
9 Customer Q&As for Mouse IL-23 ELISA Kit PicoKine®
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2020-12-23
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2020-12-23
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis IL-23A using the EK0866 Mouse IL-23A Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2020-11-14
Answer
A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample on-stat collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to prevent protein degradation.
Boster Scientific Support
Answered: 2020-11-14
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2020-10-19
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/elisa-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/elisa-data-analysis-instructions
Boster Scientific Support
Answered: 2020-10-19
Question
Q: if the enzyme conjugated IL-23A antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the IL-23A antigen?
Verified Customer
Verified customer
Asked: 2020-04-11
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2020-04-11
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
P. Zhang
Verified customer
Asked: 2019-01-25
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2019-01-25
Question
Q: how are cell lysates prepared for use in Picokine® ELISA kits?
L. Evans
Verified customer
Asked: 2018-03-16
Answer
A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2018-03-16
Question
Q: can I use EDTA plasma as samples in Mouse IL-23A Picokine® ELISA Kit (Catalog # EK0866)?
Y. Puri
Verified customer
Asked: 2016-10-09
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can attach metal ions from the functional domain of IL-23A causing disruption of its protein structure. IL-23A may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the IL-23A ELISA, treating samples with a number of anticoagulants and decided that heparin can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2016-10-09
Question
Q: how to analyze ELISA data? I have obtained IL-23A level in plasma.
Verified Customer
Verified customer
Asked: 2015-01-29
Answer
A: we recommend you this article on ELISA data analysis. bosterbio.com/elisa-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/elisa-data-analysis-online
Boster Scientific Support
Answered: 2015-01-29
Question
Just want to know if the product EK0866 antibody kit can be used to detect in mouse brain tissue homogenate?
Verified Customer
Verified customer
Asked: 2014-07-18
Answer
The product EK0866 antibody kit have been validated and tested only in culture supernatant, serum and citrate plasma, however it might be suitable to use in untested sample types like tissue lysates.
Boster Scientific Support
Answered: 2014-07-18