Product Info Summary
SKU: | EK1250 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Mouse |
Application: | ELISA |
Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Mouse Renin 1/Ren1 ELISA Kit PicoKine®
SKU/Catalog Number
EK1250
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse Renin 1/Ren1 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Ren1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse Renin 1/Ren1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1250)
Clonality of Antibodies
See Datasheet for details
Immunogen
Expression system for standard: NS0; Immunogen sequence: S72-R402
Sensitivity
<10 pg/ml
Assay Range
62.5 pg/ml - 4,000 pg/ml
Standard Dilution Instructions
Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1250 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1250 is reactive to Ren1 in Mouse samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK1250 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Renin
Renin-1 is also known as Ren, Angiotensinogenase or Kidney rennin. It is a member of peptidase A1 family. Renin is a highly specific endopeptidase, whose only known function is to generate angiotensin I from angiotensinogen in the plasma, initiating a cascade of reactions that produce an elevation of blood pressure and increased sodium retention by the kidney. It associated to membranes via binding to ATP6AP2.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1250-CAP | Anti-Mouse Ren1 Pre-coated 96-well strip microplate | 1 |
EK1250-ST | Mouse Ren1 Standard | 2 vials, 10 ng/tube |
EK1250-DA | Mouse Ren1 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Innovating Scientists Reward
If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.
Submit A Review
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 62.5 | 125 | 250 | 500 | 1000 | 2000 | 4000 |
O.D. | 0.023 | 0.096 | 0.195 | 0.235 | 0.379 | 0.578 | 1.061 | 1.834 |
Data Example Images
Click image to see more details
Mouse Renin-1 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Renin, Dilution ratio of 1:100, concentration in serum and plasma is 20-30 ng/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse Renin 1/Ren1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 158 | 449 | 1246 | 147 | 482 | 1262 |
Standard deviation | 10.74 | 28.73 | 64.79 | 11.9 | 34.22 | 70.67 |
CV (%) | 6.8% | 6.4% | 5.2% | 8.1% | 7.1% | 5.6% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of Renin in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 158 | 161 | 142 | 150 | 152 | 7.39 | 4.8% |
Sample 2 | 449 | 465 | 437 | 476 | 456 | 14.9 | 3.2% |
Sample 3 | 1246 | 1215 | 1179 | 1158 | 1199 | 33.7 | 2.8% |
Protein Target Info & Infographic
Gene/Protein Information For Ren1 (Source: Uniprot.Org, NCBI)
Gene Name
Ren1
Full Name
Renin-1
Weight
44.343kDa
Superfamily
peptidase A1 family
Alternative Names
angiotensin-forming enzyme; Angiotensinogenase; EC 3.4.23; EC 3.4.23.15; FLJ10761; HNFJ2; REN; renin precursor, renal; Renin Ren1|D19352, R, Re, Ren, Ren-1, Ren-Ac, Ren1d, Rn, Rn-1, Rnr, Ren1|renin 1 structural|renin-1|angiotensinogenase|aspartyl-protease|kidney renin|renin b
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Ren1, check out the Ren1 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Ren1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Mouse Renin 1/Ren1 ELISA Kit PicoKine® (EK1250)
Hello CJ!
No publications found for EK1250
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Mouse Renin 1/Ren1 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
Be the first to review Mouse Renin 1/Ren1 ELISA Kit PicoKine®
*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
7 Customer Q&As for Mouse Renin 1/Ren1 ELISA Kit PicoKine®
Question
Q: Can Renin ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2020-06-25
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2020-06-25
Question
Q: how to proceed with the analysis of ELISA data? I have performed Renin level in plasma.
H. Anderson
Verified customer
Asked: 2020-01-08
Answer
A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online
Boster Scientific Support
Answered: 2020-01-08
Question
Q: how much samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2019-10-29
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2019-10-29
Question
Q: What is the optimal O.D. value for Renin ELISA kit? I performed your Renin ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain Renin even though the O.D. values are not very high?
C. Lopez
Verified customer
Asked: 2018-06-16
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this Renin ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of Renin that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2018-06-16
Question
Q: how can I thaw whole blood sample for Renin ELISA after freezing?
Verified Customer
Verified customer
Asked: 2018-02-23
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test Renin for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.
Boster Scientific Support
Answered: 2018-02-23
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2016-05-06
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2016-05-06
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring Renin using the EK1250 Mouse Renin Picokine® ELISA Kit?
S. Hernandez
Verified customer
Asked: 2015-05-30
Answer
A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to prevent protein degradation.
Boster Scientific Support
Answered: 2015-05-30