Mouse Thrombomodulin ELISA Kit PicoKine®

Thrombomodulin/BDCA-3 ELISA kit for Mouse

Mouse Thrombomodulin ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Thbd in cell culture supernatants, serum, plasma (heparin, EDTA, citrate) and urine. Sensitivity: 10pg/ml.

Product Info Summary

SKU: EK1119
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, serum, plasma (heparin, EDTA, citrate) and urine.

Product Name

Mouse Thrombomodulin ELISA Kit PicoKine®

View all Thrombomodulin/BDCA-3 ELISA kits

SKU/Catalog Number

EK1119

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse Thrombomodulin ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Thbd in cell culture supernatants, serum, plasma (heparin, EDTA, citrate) and urine. Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse Thrombomodulin ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1119)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: L17-S517

Sensitivity

<10 pg/ml

Assay Range

62.5 pg/ml - 4,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1119 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1119 is reactive to THBD in Mouse samples

Validated Sample Types

cell culture supernatants, serum, plasma (heparin, EDTA, citrate) and urine.

Application Guarantee

EK1119 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Thrombomodulin/BDCA-3

Thrombomodulin (TM), CD141 or BDCA-3 is an integral membrane protein expressed on the surface of endothelial cells and serves as a cofactor for thrombin. It reduces blood coagulation by converting thrombin to an anticoagulant enzyme from a procoagulant enzyme. Thrombomodulin is also expressed on human mesothelial cell, monocyte and a dendritic cell subset. In humans, thrombomodulin is encoded by the THBD gene. The protein has a molecular mass of 74kDa, and consists of a single chain with 5 distinct domains. Thrombomodulin functions as a cofactor in the thrombin-induced activation of protein C in the anticoagulant pathway by forming a 1:1 stoichiometric complex with thrombin. This raises the speed of protein C activation thousandfold. Thrombomodulin-bound thrombin has procoagulant effect at the same time by inhibiting fibrinolysis by cleaving thrombin-activatable fibrinolysis inhibitor (TAFI,aka carboxypeptidase B2) into its active form. Thrombomodulin is a glycoprotein on the surface of endothelial cells that, in addition to binding thrombin, regulates C3b inactivation by factor I. Mutations in the thrombomodulin gene (THBD) have also been reported to be associated with atypical hemolytic-uremic syndrome (aHUS).

Kit Components

Catalog Number Description Quantity
EK1119-CAP Anti-Mouse THBD Pre-coated 96-well strip microplate 1
EK1119-ST Mouse THBD Standard 2 vials, 10 ng/tube
EK1119-DA Mouse THBD Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)062.5125250500100020004000
O.D.0.0070.1550.2840.4760.8061.3131.8182.166

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Thrombomodulin/BDCA-3, For serum, dilution ratio is 1:20 and concentration is 12296-35284 pg/ml.
For plasma, dilution ratio is 1:20 and concentration is 9384-29772 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse Thrombomodulin ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)15445013901694081348
Standard deviation6.4633.357.49.4638.9160.66
CV (%)4.2%7.4%4%5.6%8.9%4.5%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Thrombomodulin/BDCA-3 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 11541441401481465.173.5%
Sample 245048851145147525.815.4%
Sample 313901680163014931548114.167.3%
*number of samples for each test n=16.

Gene/Protein Information For THBD (Source: Uniprot.Org, NCBI)

Gene Name

THBD

Full Name

Thrombomodulin

Weight

60.329kDa

Alternative Names

BDCA3; BDCA-3; CD141 antigen; CD141; Fetomodulin; THBD; THRM; Thrombomodulin; TM THBD AHUS6, BDCA-3, BDCA3, CD141, THPH12, THRM, TM thrombomodulin thrombomodulin|CD141 antigen|fetomodulin

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on THBD, check out the THBD Infographic

THBD infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for THBD: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1119

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse Thrombomodulin ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Mouse Thrombomodulin ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Mouse Thrombomodulin ELISA Kit PicoKine®

Question

Q: What is the optimal O.D. value for Thrombomodulin ELISA kit? I used your Thrombomodulin ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain Thrombomodulin even though the O.D. values are not very high?

K. Taylor

Verified customer

Asked: 2020-06-08

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this Thrombomodulin ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of Thrombomodulin that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2020-06-08

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-10-17

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2019-10-17

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

B. Dhar

Verified customer

Asked: 2019-07-28

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer may impact immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2019-07-28

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

C. Martin

Verified customer

Asked: 2018-11-30

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-11-30

Question

Q: Can Thrombomodulin ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

L. Brown

Verified customer

Asked: 2018-11-10

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-11-10

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

P. Chen

Verified customer

Asked: 2018-08-09

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is needed for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2018-08-09

Question

Q: how to analyze ELISA data? I have performed Thrombomodulin level in plasma.

Verified Customer

Verified customer

Asked: 2018-05-08

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2018-05-08

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement Thrombomodulin using the EK1119 Mouse Thrombomodulin Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2018-01-14

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. avoid repetitive freeze-thaw cycles with the stored samples to prevent protein degradation.

Boster Scientific Support

Answered: 2018-01-14

Question

Q: if the enzyme conjugated Thrombomodulin antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Thrombomodulin antigen?

Verified Customer

Verified customer

Asked: 2016-11-21

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2016-11-21

$499
In stock, 1 left.

Order within 1 hours and 19 minutes to receive by Wed May 15

Get A Quote
In stock
Order Product
EK1119
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.