Mouse TIMP-2 ELISA Kit PicoKine®

TIMP-2 ELISA kit for Mouse

Mouse TIMP-2 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Timp2 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. Cited in 6 publication(s).

Product Info Summary

SKU: EK0955
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse TIMP-2 ELISA Kit PicoKine®

View all TIMP-2 ELISA kits

SKU/Catalog Number

EK0955

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse TIMP-2 ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Timp2 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse TIMP-2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0955)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: C27-P220

Sensitivity

<10 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK0955 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0955 is reactive to TIMP2 in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0955 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of TIMP-2

TIMP-2 gen is encoded by 5 exons spanning 83 kb of genomic DNA. TIMP-2 is 83 kilobase pairs (kb) long with exon-intron splicing sites located in preserved positions among the three members of the TIMP family. The gene for tissue inhibitor of metalloproteinases-2 is localized on human chromosome arm 17q25. TIMP-2 abrogates angiogenic factor-induced endothelial cell proliferation in vitro and angiogenesis in vivo independent of MMP inhibition. The standard product used in this kit is recombinant human TIMP-2 with the molecular mass of 22Kda and 194 amino acid.

Kit Components

Catalog Number Description Quantity
EK0955-CAP Anti-Mouse TIMP2 Pre-coated 96-well strip microplate 1
EK0955-ST Mouse TIMP2 Standard 2 vials, 10 ng/tube
EK0955-DA Mouse TIMP2 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512502500500010000
O.D.0.0180.0540.1050.1890.4580.7591.4682.067

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect TIMP-2, Dilution ratio of 1:200, concentration in serum and plasma is 201-319 ng/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse TIMP-2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)1931314424817912834028
Standard deviation10.4267.01318.610.9184.67370.57
CV (%)5.4%9.2%%7.5%6.1%6.6%9.2%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of TIMP-2 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 11932121962012007.223.6%
Sample 21314118310901242120782.066.7%
Sample 342484225455848254464246.445.5%
*number of samples for each test n=16.

Gene/Protein Information For TIMP2 (Source: Uniprot.Org, NCBI)

Gene Name

TIMP2

Full Name

Metalloproteinase inhibitor 2

Weight

24.399kDa

Superfamily

protease inhibitor I35 (TIMP) family

Alternative Names

CSC-21Ktissue inhibitor of metalloproteinase 2; metalloproteinase inhibitor 2; TIMP metallopeptidase inhibitor 2; TIMP2; TIMP-2; Tissue inhibitor of metalloproteinases 2 TIMP2 CSC-21K, DDC8 TIMP metallopeptidase inhibitor 2 metalloproteinase inhibitor 2|testicular secretory protein Li 57|tissue inhibitor of metalloproteinases 2

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on TIMP2, check out the TIMP2 Infographic

TIMP2 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for TIMP2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK0955 has been cited in 6 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Acute exacerbations of COPD are associated with significant activation of matrix metalloproteinase 9 irrespectively of airway obstruction, emphysema and infection

Cavdar Z, Ozbal S, Celik A, Ergur Bu, Guneli E, Ural C, Camsari T, Guner Ga. Biotech Histochem. 2014 May;89(4):304-14. Doi: 10.3109/10520295.2013.847498. Epub 2013 Oct 28. The Effects Of Alpha-Lipoic Acid On Mmp-2 And Mmp-9 Activities In A Rat Ren...

Xu Xl, Ling Dy, Zhu Qy, Fan Wj, Zhang W. Eur J Pharmacol. 2013 Jan 5;698(1-3):370-8. Doi: 10.1016/J.Ejphar.2012.11.019. Epub 2012 Nov 21. The Effect Of 2,3,4',5-Tetrahydroxystilbene-2-0-??-D Glucoside On Neointima Formation In A Rat Artery Balloon...

Yu X, Zhu J, Mi M, Chen W, Pan Q, Wei M. Med Oncol. 2012 Mar;29(1):349-57. Doi: 10.1007/S12032-010-9770-2. Epub 2010 Dec 4. Anti-Angiogenic Genistein Inhibits Vegf-Induced Endothelial Cell Activation By Decreasing Ptk Activity And Mapk Activation.

Gishto A, Farrell K, Kothapalli Cr. J Biomed Mater Res A. 2015 Feb;103(2):693-708. Doi: 10.1002/Jbm.A.35217. Epub 2014 May 19. Tuning Composition And Architecture Of Biomimetic Scaffolds For Enhanced Matrix Synthesis By Murine Cardiomyocytes.

Kim Ks, Lee Ya, Choi Hm, Yoo Mc, Yang Hi. Rheumatol Int. 2012 Oct;32(10):3069-75. Epub 2011 Sep 13. Implication Of Mmp-9 And Urokinase Plasminogen Activator (Upa) In The Activation Of Pro-Matrix Metalloproteinase (Mmp)-13.

Have you used Mouse TIMP-2 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Mouse TIMP-2 ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

11 Customer Q&As for Mouse TIMP-2 ELISA Kit PicoKine®

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

W. Dhawan

Verified customer

Asked: 2020-09-12

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2020-09-12

Question

Q: is it okay to use citrate plasma as samples in Mouse TIMP-2 Picokine® ELISA Kit (Catalog # EK0955)?

Verified Customer

Verified customer

Asked: 2020-08-20

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can attach metal ions from the functional domain of TIMP-2 causing disruption of its protein structure. TIMP-2 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the TIMP-2 ELISA, treating samples with a number of anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2020-08-20

Question

Do you have information regarding the target epitope for the antibody in your TIMP2 ELISA kit?

Verified customer

Asked: 2019-04-22

Answer

Unfortunately, we do not do epitope mapping for our antibodies, so we are only able to provide the immunogen sequence.

Boster Scientific Support

Answered: 2019-04-22

Question

Q: Can TIMP-2 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2019-04-17

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2019-04-17

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

P. Walker

Verified customer

Asked: 2018-10-15

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2018-10-15

Question

Q: What is the optimal O.D. value for TIMP-2 ELISA kit? I performed your TIMP-2 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain TIMP-2 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2018-10-04

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. considering your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this TIMP-2 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of TIMP-2 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2018-10-04

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2018-07-10

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-07-10

Question

Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?

D. Lee

Verified customer

Asked: 2017-05-21

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can impact immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2017-05-21

Question

Q: if the enzyme conjugated TIMP-2 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the TIMP-2 antigen?

S. Yang

Verified customer

Asked: 2017-03-06

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2017-03-06

Question

Q: we need your recommendation regarding the dilution ratio of serum samples for detection of TIMP-2 in Mouse plasma? I am trying to measure a multiple analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.

W. Kaur

Verified customer

Asked: 2014-11-26

Answer

A: without having an understanding the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the TIMP-2 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2014-11-26

Question

Q: how to analyze ELISA data? I measured TIMP-2 level in plasma.

Verified Customer

Verified customer

Asked: 2014-05-03

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2014-05-03

$499
In stock, 2 left.

Order within 35 hours and 10 minutes to receive by Wed May 22

Get A Quote
In stock
Order Product
EK0955
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.