Western blotting, also known as immunoblotting, is a core method in molecular biology for detecting specific proteins within a complex sample. Developed in 1979 by W. Neal Burnette, Western blotting—also called immunoblotting—is a widely used method for detecting specific proteins in a sample. Adapted from earlier blotting techniques, it remains a standard in molecular biology. The process involves separating proteins by gel electrophoresis, transferring them to a membrane such as PVDF membranes or nitrocellulose, and using antibodies for detection.
Western blotting is commonly used to confirm protein expression and post-translational changes. It plays a key role in research and diagnostics, including HIV detection and studies of cancer and neurodegenerative diseases. Its reliability makes it essential in protein analysis workflows. Researchers often start with cell culture experiments and prepare extracts using cell lysis buffers containing protease inhibitor cocktail and phosphatase inhibitors to preserve protein integrity before analysis.

Let Bosterbio handle your Western blot CRO services and be your long term partner in broadening the bandwidth of your lab/team in a flexible manner.
The first step of gel preparation is to determine the gel percentage based on the molecular weight of your protein sample:
| Protein Size (kDa) | >100 | 30-100 | 10-30 | <10 |
|---|---|---|---|---|
| Gel Percentage | 8% | 10% | 12% | 15% |
If you are not sure of the size of your protein or are looking at proteins of a variety of molecular weights, then a gradient gel may provide the best resolution.
Notes
Dual Color Protein Loading Buffer is designed to prevent protein degradation during sample heating prior to electrophoresis and is able to work against pH changes during SDS-PAGE run. Many proteins are sensitive to pH changes that result from temperature fluctuations of Tris buffers during electrophoresis. It contains two tracking dyes: blue (Bromophenol Blue) for tracking the progress of electrophoresis and pink (Pyronin Y) for monitoring protein transfer to the membrane. Refer to the datasheet on our website for more information.
After electrophoresis, we recommend using one of our gel staining solutions to determine if the electrophoretic separation worked. Please refer to the datasheet(s) on our website for more information.
Note: Stained gel cannot be used in the subsequent protein transfer procedure.
We recommend using one of the filter papers from Boster:
After transfer, membranes must be blocked to reduce background. Washing steps typically include buffers like Tris Buffered Saline or Phosphate Buffered Saline supplemented with Tween 20.
After blocking, the membrane is incubated with a primary antibody that binds to the target protein, followed by an appropriate detection-compatible secondary antibody. HRP- or AP-conjugated secondary antibodies are used with enzyme-based detection; fluorophore-conjugated secondary antibodies are used for direct fluorescence imaging. Match the secondary antibody to the primary antibody host species and relevant immunoglobulin class.
Wash the membrane 3 times with the TBS Wash Buffer for 10 minutes each to remove the unbound antibodies.
Wash the membrane 3-6 times with the TBS Wash Buffer for 10 minutes each to remove unbound antibodies, or use the wash conditions specified for the chosen detection system.
Fluorescent detection note: Choose a WB-compatible fluorophore-conjugated secondary antibody and a compatible antibody diluent or blocking buffer. Protect fluorescent antibodies and membranes from unnecessary light exposure; for multichannel detection, check secondary-antibody cross-reactivity and channel overlap. For example, Boster Fluoro647 Goat Anti-Rabbit IgG (BA1150) lists Western blotting among its tested applications. Follow the specific antibody datasheet for working dilution and incubation conditions.
Signal detection can use chemiluminescent, colorimetric, or fluorescent methods. Choose the method by matching the antibody label, appropriate substrate (if required), membrane, and available imaging equipment. Enhanced chemiluminescence (ECL) uses HRP and a compatible light-producing substrate; colorimetric systems use an enzyme-matched chromogenic substrate; direct fluorescence uses fluorophore-labeled antibodies and a suitable fluorescent imager. Fluorescent Western blotting can use compatible low-background PVDF or nitrocellulose membranes, depending on the imaging wavelengths and validated workflow.
Below are the existing ECL and colorimetric workflows, followed by practical notes for fluorescent detection. For detection principles and comparative performance, see Western Blotting Principle; for experiment-specific method selection, see Western Blotting Optimization.
Before adding a substrate or imaging the membrane, confirm that the antibody label and detection chemistry are compatible. An enzyme-based signal requires the matching substrate; a fluorophore-labeled secondary antibody is detected directly and does not require an ECL or chromogenic substrate.
| Detection Method | Compatible Antibody Label | Reagent / Equipment |
|---|---|---|
| Chemiluminescent (ECL) | HRP | HRP-compatible ECL substrate and film or chemiluminescence imager |
| Fluorescent | Fluorophore (such as Fluoro647) | Fluorescence imager with matching excitation/emission channels; no enzyme substrate |
| Colorimetric | HRP or alkaline phosphatase (AP) | Appropriate chromogenic substrate (for example, HRP/DAB or AP/BCIP-NBT) |
In an HRP-based ECL system, the HRP label catalyzes a reaction in the luminol-based substrate that emits light. Capture the resulting chemiluminescence using X-ray film or a compatible digital chemiluminescence imager. Follow the product-specific substrate instructions; different Boster ECL products have different preparation requirements.
| Origin of Primary Antibody Species | Catalog # of ECL Kit* |
|---|---|
| Mouse IgG | EK1001 |
| Rabbit IgG | EK1002 |
| Goat IgG | EK1003 |
| Rat IgG | EK1004 |
| Mouse IgM | EK1005 |
* Each kit has sufficient reagents for 800 cm2 of membrane.
† Earlier Boster ECL kit formats combined substrate components, blocking buffer, and an HRP-conjugated secondary antibody. The following table preserves historical standalone reagent references and adds the currently documented ECL Plus substrate. Check current SKU availability and the product-specific instructions before preparing a working solution; the table includes both ready-to-use and concentrated formats.
| Reagent A | Reagent B | ||||
|---|---|---|---|---|---|
| Product | Conc. | Volume | Conc. | Volume | Catalog # |
| Hypersensitive ECL Chemiluminescent Substrate (legacy listing) | 1X** | 100 mL | 1X** | 100 mL | AR1170 |
| ECL Plus Western Blotting Substrate | 1X** | 100 mL | 1X** | 100 mL | AR1196-200 |
| Hypersensitive WB Chemiluminescent Substrate | 20X | 5 mL | 20X | 5 mL | CR0001-5 |
| Hypersensitive WB Chemiluminescent Substrate | 20X | 10 mL | 20X | 10 mL | CR0001-10 |
| Hypersensitive WB Chemiluminescent Substrate | 20X | 25 mL | 20X | 25 mL | CR0001-25 |
** Ready-to-use 1X components; prepare the working solution according to the specific product instructions.
Record the test result using autoradiography film or CHEMIDOC in a darkroom. For autoradiography film, exposure time for the specific antigen depends on the developing effect, which could range from seconds to minutes.
For film detection, use a compatible developing and fixing procedure (Boster previously listed WB Developing Fixing Kit, AR0132). A digital chemiluminescence imager can record the light signal directly and does not require film development.
Notes
Prepare DAB or BCIP/NBT substrate solution described below.
| Origin of Primary Antibody Species | Color | Catalog # of DAB Kit |
|---|---|---|
| Mouse IgG | Yellow | SA2020 |
| Goat IgG | Yellow | SA2021 |
| Rabbit IgG | Yellow | SA2022 |
| Rat IgG | Yellow | SA2023 |
| Mouse IgG | Blue | SA2024 |
| Rabbit IgG | Blue | SA2025 |
Fluorescent Western blotting uses a WB-compatible fluorophore-labeled primary or secondary antibody. Unlike ECL and enzyme-based colorimetric detection, no enzyme substrate is added for direct fluorescence imaging. Use the instructions for the selected antibodies, membrane, and imaging system rather than applying the ECL exposure or substrate-development steps above.
For a confirmed Boster example, see Fluoro647 Goat Anti-Rabbit IgG (BA1150) (WB listed in the official product information). See our Western Blotting Optimization guide for method selection. Exact dilutions, incubation times, wash conditions, and scan settings should follow the antibody and instrument documentation.
After signal detection, quantitative comparisons require suitable image acquisition, background correction, and normalization. Use the dedicated guide for detailed image-analysis procedures rather than repeating them in this protocol.
Record band signals within the validated, non-saturated response range, measure band intensities consistently, and choose an appropriate normalization strategy for the experimental design. Our Western Blot Quantification tutorial covers ImageJ/Fiji densitometry, background subtraction, loading-control and total-protein normalization, fold-change calculations, and data reporting.
Explore Western Blot QuantificationLearn the principle behind Western blotting, including protein separation by SDS-PAGE and target detection through membrane blotting and antibody-based analysis.
Review Western blot sample preparation guidance to help improve protein extraction, handling, and sample quality across different sample types.
Troubleshoot common Western blot issues such as weak signal, incorrect band size, smiling gels, and high background with practical tips.
Explore Western blot optimization tips for transfer, blocking, antibody incubation, and detection to improve assay performance and consistency.
Before you move on to blocking, make sure the membrane is worth taking forward. A Western blot can start failing long before the antibodies ever touch the membrane.
PVDF or Nitrocellulose? A practical guide to choosing the right membrane based on workflow, reprobing needs, and downstream use.
How to Strip and Re-probe Cleanly? A verification-first workflow to prevent ghost bands and high background.
A step-by-step technical guide to ImageJ/Fiji densitometry, background subtraction, normalization, and reliable interpretation of Western blot band intensities.