Product Info Summary
| SKU: | EK0725 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Rat |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Rat MIP-2 ELISA Kit PicoKine®
SKU/Catalog Number
EK0725
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Rat MIP-2 ELISA Kit PicoKine® (96 Tests). Quantitate Rat Cxcl2 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Rat MIP-2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0725)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: E.coli; Immunogen sequence: S32-N100
Capture/Detection Antibodies
The capture antibody is monoclonal antibody from mouse and the detection antibody is polyclonal antibody from goat.
Sensitivity
<10 pg/ml
Assay Range
15.6 pg/ml - 1,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0725 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0725 is reactive to Cxcl2 in Rat samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK0725 is guaranteed for ELISA in Rat by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Cxcl2
Macrophage Inflammatory Protein 2 (MIP2), also known as C-X-C motif chemokine 2 (CXCL2), is a small cytokine belonging to the CXC chemokine family. MIP2 forms homotetramers. MIP2 is produced by activated monocytes and neutrophils and expressed at sites of inflammation. MIP2 is chemotactic for polymorphonuclear leukocytes.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0725-CAP | Anti-Rat Cxcl2 Pre-coated 96-well strip microplate | 1 |
| EK0725-ST | Rat Cxcl2 Standard | 2 vials, 10 ng/tube |
| EK0725-DA | Rat Cxcl2 Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 15.6 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 |
| O.D. | 0.047 | 0.112 | 0.159 | 0.276 | 0.509 | 0.905 | 1.549 | 2.294 |
Data Example Images
Click image to see more details
Rat CXCL2 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Cxcl2, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 15.6 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Rat MIP-2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 35 | 171 | 537 | 31 | 178 | 563 |
| Standard deviation | 2.69 | 2.89 | 21.48 | 2.88 | 8.36 | 27.02 |
| CV (%) | 7.7% | 4.6% | 4% | 9.3% | 4.7% | 4.8% |
Specific Publications For Rat MIP-2 ELISA Kit PicoKine® (EK0725)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Rat MIP-2 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
5 Customer Q&As for Rat MIP-2 ELISA Kit PicoKine®
Question
Q: we need your suggestion regarding the dilution ratio of serum samples for detection of CXCL2 in Rat serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.
E. Thomas
Verified customer
Asked: 2019-11-20
Answer
A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CXCL2 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/elisa-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2019-11-20
Question
Q: can I use citrate plasma as samples in Rat CXCL2 Picokine® ELISA Kit (Catalog # EK0725)?
Verified Customer
Verified customer
Asked: 2019-02-04
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of CXCL2 causing degradation of its protein structure. CXCL2 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the CXCL2 ELISA, treating samples with a number of anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2019-02-04
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2018-12-23
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/elisa-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/elisa-data-analysis-instructions
Boster Scientific Support
Answered: 2018-12-23
Question
Q: Can CXCL2 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2018-11-09
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2018-11-09
Question
Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2017-03-04
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2017-03-04