Product Info Summary
| SKU: | EK0350 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Rat |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA, citrate). |
Product info
Product Name
Rat Fibronectin ELISA Kit PicoKine®
SKU/Catalog Number
EK0350
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Rat Fibronectin ELISA Kit PicoKine® (96 Tests). Quantitate Rat Fn1 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Rat Fibronectin ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0350)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Target protein isolated from rat plasma
Capture/Detection Antibodies
The capture antibody is monoclonal antibody from mouse and the detection antibody is polyclonal antibody from goat.
Sensitivity
<15 pg/ml
Assay Range
156 pg/ml - 10,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0350 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0350 is reactive to Fn1 in Rat samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA, citrate).
Application Guarantee
EK0350 is guaranteed for ELISA in Rat by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Fn1
Fibronectin (FN) also known as LETS, is identified on the surfFN of fibroblasts by labeling with radioactive compounds or specific antibodies. Fibronectin is a 430,000-dalton dimeric glycoprotein that exists in 2 forms, termed cellular and plasma fibronectin. Cellular and plasma fibronectins are heterodimers consisting of similar but not identical polypeptides. These two forms of FN differ in biologic activity. Fibronectins bind cell surfFNs and various compounds including collagen, fibrin, heparin, DNA, and actin. Because fibronectin stimulates endocytosis in several systems and promotes the clearance of particulate material from the circulation, it could function in the clearance of C1q-coated material such as immune complexes or cellular debris. Fibronectins are involved in cell adhesion, cell motility, opsonization, would healing, and maintenance of cell shape. LETS, encoded on chromosome 8, is responsible for the LETS protein expression in humans. Because LETS has been implicated in tumorigenicity and cellular transformation, it is of interest that rearrangement or modifications in the number of chromosome 8 have been associated with certain forms of cancer. The standard used in this kit is isolated from rat plasma with the molecular mass of 200-250KDa.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0350-CAP | Anti-Rat Fn1 Pre-coated 96-well strip microplate | 1 |
| EK0350-ST | Rat Fn1 Standard | 2 vials, 10 ng/tube |
| EK0350-DA | Rat Fn1 Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 156 | 312 | 625 | 1250 | 2500 | 5000 | 10000 |
| O.D. | 0.025 | 0.123 | 0.18 | 0.312 | 0.546 | 0.919 | 1.445 | 2.036 |
Data Example Images
Click image to see more details
Rat Fibronectin PicoKine ELISA Kit standard curve
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Rat Fibronectin ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 342 | 1852 | 4326 | 361 | 1834 | 4010 |
| Standard deviation | 23.25 | 85.49 | 190.34 | 29.96 | 102.7 | 216.54 |
| CV (%) | 6.8% | 4.6% | 4.4% | 8.3% | 5.6% | 5.4% |
Specific Publications For Rat Fibronectin ELISA Kit PicoKine® (EK0350)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Rat Fibronectin ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
5 Customer Q&As for Rat Fibronectin ELISA Kit PicoKine®
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
E. Miller
Verified customer
Asked: 2020-12-02
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/elisa-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/elisa-data-analysis-instructions
Boster Scientific Support
Answered: 2020-12-02
Question
Q: we need your recommendation regarding the dilution ratio of serum samples for detection of Fibronectin in Rat serum? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.
D. Thomas
Verified customer
Asked: 2020-07-04
Answer
A: without having an understanding the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the Fibronectin ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/elisa-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2020-07-04
Question
Q: how do I analyze ELISA data? I have obtained Fibronectin level in serum.
Verified Customer
Verified customer
Asked: 2019-09-01
Answer
A: we recommend you this article on ELISA data analysis. bosterbio.com/elisa-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/elisa-data-analysis-online
Boster Scientific Support
Answered: 2019-09-01
Question
Q: What is the optimal O.D. value for Fibronectin ELISA kit? I used your Fibronectin ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain Fibronectin even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2019-01-27
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this Fibronectin ELISA kit to have sensitivity of 15pg/ml, that means the minimum amount of Fibronectin that can be declared/interpreted as positive by the above standard is 15pg/ml.
Boster Scientific Support
Answered: 2019-01-27
Question
Q: is it okay to use heparin plasma as samples in Rat Fibronectin Picokine® ELISA Kit (Catalog # EK0350)?
Verified Customer
Verified customer
Asked: 2018-11-20
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can sequester metal ions from the functional domain of Fibronectin causing degradation of its protein structure. Fibronectin may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the Fibronectin ELISA, treating samples with different anticoagulants and decided that heparin, EDTA or citrate can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2018-11-20