Rat IL-4/Interleukin-4 ELISA Kit PicoKine®

Il4 ELISA kit for Rat

Rat IL-4/Interleukin-4 ELISA Kit PicoKine® (96 Tests). Quantitate Rat Il4 in cell culture supernatants and serum. Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 55 publication(s).

Product Info Summary

SKU: EK0406
Size: 96 wells/kit, with removable strips.
Reactive Species: Rat
Application: ELISA
Sample Types: cell culture supernatants and serum.

Product Name

Rat IL-4/Interleukin-4 ELISA Kit PicoKine®

SKU/Catalog Number

EK0406

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Rat IL-4/Interleukin-4 ELISA Kit PicoKine® (96 Tests). Quantitate Rat Il4 in cell culture supernatants and serum. Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Rat IL-4/Interleukin-4 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0406)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: C25-S147

Capture/Detection Antibodies

The capture antibody is monoclonal antibody from mouse and the detection antibody is polyclonal antibody from goat.

Sensitivity

<1 pg/ml

Assay Range

15.6 pg/ml - 1,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0406 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0406 is reactive to Il4 in Rat samples

Validated Sample Types

cell culture supernatants and serum.

Application Guarantee

EK0406 is guaranteed for ELISA in Rat by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Il4

Interleukin-4 (IL-4), also knowns as a B-cell stimulatory factor1 (BSF1), is an immunomodulatory cytokine, which can inhibit the growth of tumour cells. The human cDNA contains a single open reading frame encoding a protein of 153 amino acids, including a putative signal peptide. IL-4 may act as an autocrine growth factor in pancreatic cancer cells and also give rise to the possibility that cancer-derived IL-4 may suppress cancer-directed immunosurveillance in vivo in addition to its growth-promoting effects, thereby facilitating pancreatic tumor growth and metastasis. The mouse and human genes and their protein products show structural and functional similarities. The human IL-4 gene, which occurs as a single copy in the haploid genome, is mapped on chromosome 5. Rat IL-4 is a 13.5KDa glycoprotein, consisting of 147 amino acids in precursor form and 123 amino acids in mature form.

Kit Components

Catalog Number Description Quantity
EK0406-CAP Anti-Rat Il4 Pre-coated 96-well strip microplate 1
EK0406-ST Rat Il4 Standard 2 vials, 10 ng/tube
EK0406-DA Rat Il4 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015.631.262.51252505001000
O.D.0.0390.0940.1330.220.4060.7261.2511.799

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Il4, Dilution ratio of 1:1, concentration in serum is less than the lowest standard, 15.6 pg/ml..

Some articles we found to cite concentrations of Il4 in samples: 16083555 (Pubmed IDs).

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Rat IL-4/Interleukin-4 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3516445632175481
Standard deviation2.4510.6621.432.411.3728.37
CV (%)7%6.5%4.7%7.5%6.5%5.9%

Loading publications

No publications found

Do you have publications using this product? Share with us and receive a reward. Contact us for more information.

Publications not available. Please try again later.

Product has been cited in publications

No results found matching your query

  • Published: --- Journal: --- Application: --- Impact Factor: --- Species: --- PMID: --- View Article

0 Reviews For Rat IL-4/Interleukin-4 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

5 Customer Q&As for Rat IL-4/Interleukin-4 ELISA Kit PicoKine®

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-05-25

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2020-05-25

Question

Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2019-10-31

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2019-10-31

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2018-09-10

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2018-09-10

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2015-11-28

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/elisa-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/elisa-data-analysis-instructions

Boster Scientific Support

Answered: 2015-11-28

Question

Q: Can IL-4 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2014-02-01

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is a must. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2014-02-01

$499
In stock, 1 left.

Order within 46 hours and 37 minutes to receive by Tue Apr 28

Get A Quote
In stock
Order Product
EK0406
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.

This product is for Research Use Only. Not for use in diagnostic procedures.

Update date: Apr 12, 2026