Product Info Summary
| SKU: | A18230 |
|---|---|
| Size: | 100μl |
| Reactive Species: | Human |
| Host: | Rabbit |
| Application: | ELISA, IF, WB |
Customers Who Bought This Also Bought
Product info
Product Name
Anti-Olfactory receptor 10G2 Antibody
SKU/Catalog Number
A18230
Size
100μl
Form
Liquid
Description
Boster Bio Anti-Olfactory receptor 10G2 Antibody catalog # A18230. Tested in WB, IF, ELISA applications. This antibody reacts with Human.
Storage & Handling
Store at -20°C for one year. For short term storage and frequent use, store at 4°C for up to one month. Avoid repeated freeze-thaw cycles.
Cite This Product
Anti-Olfactory receptor 10G2 Antibody (Boster Biological Technology, Pleasanton CA, USA, Catalog # A18230)
Host
Rabbit
Contents
Liquid in PBS containing 50% glycerol, 0.5% stabilizing protein and 0.02% sodium azide.
This antibody is supplied in a stabilized formulation.
Compatibility with conjugation reactions depends on the chemistry of the conjugation method used.
For conjugation methods that are not compatible with the stabilizing components present in this formulation, a carrier-free antibody format is required.
Clonality
Polyclonal
Isotype
IgG
Immunogen
The antiserum was produced against synthesized peptide derived from human OR10G2. AA range:241-290
Reactive Species
A18230 is reactive to OR10G2 in Human
Calculated molecular weight
34.5 kDa
Antibody Validation
Boster validates all antibodies on WB, IHC, ICC, Immunofluorescence, and ELISA with known positive control and negative samples to ensure specificity and high affinity, including thorough antibody incubations.
Application & Images
Applications
A18230 is guaranteed for ELISA, IF, WB Boster Guarantee
Assay Dilutions Recommendation
The recommendations below provide a starting point for assay optimization. The actual working concentration varies and should be decided by the user.
WB 1:500-1:2000
IF 1:200-1:1000
ELISA 1:40000
Validation Images & Assay Conditions
Click image to see more details
Immunofluorescence analysis of MCF7 cells, using OR10G2 Antibody. The picture on the right is blocked with the synthesized peptide.
Click image to see more details
Western Blot analysis of various cells using Olfactory receptor 10G2 Polyclonal Antibody
Click image to see more details
Western blot analysis of lysates from HUVEC, HeLa, MCF-7, Jurkat, and COLO cells, using OR10G2 Antibody. The lane on the right is blocked with the synthesized peptide.
Specific Publications For Anti-Olfactory receptor 10G2 Antibody (A18230)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Anti-Olfactory receptor 10G2 Antibody?
Share your experimental results or join a short interview to earn up to $1,000 in product credits or other rewards.
0 Reviews For Anti-Olfactory receptor 10G2 Antibody
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
5 Customer Q&As for Anti-Olfactory receptor 10G2 Antibody
Question
Does anti-Olfactory receptor 10G2 antibody A18230 work for WB with lung?
Verified Customer
Verified customer
Asked: 2020-01-22
Answer
According to the expression profile of lung, OR10G2 is highly expressed in lung. So, it is likely that anti-Olfactory receptor 10G2 antibody A18230 will work for WB with lung.
Boster Scientific Support
Answered: 2020-01-22
Question
Is this A18230 anti-Olfactory receptor 10G2 antibody reactive to the isotypes of OR10G2?
Verified Customer
Verified customer
Asked: 2020-01-13
Answer
The immunogen of A18230 anti-Olfactory receptor 10G2 antibody is Synthesized peptide derived from the C-terminal region of human Olfactory receptor 10G2. at AA rangle: 210-290. Could you tell me which isotype you are interested in so I can help see if the immunogen is part of this isotype?
Boster Scientific Support
Answered: 2020-01-13
Question
My question regards to test anti-Olfactory receptor 10G2 antibody A18230 on human lung for research purposes, then I may be interested in using anti-Olfactory receptor 10G2 antibody A18230 for diagnostic purposes as well. Is the antibody suitable for diagnostic purposes?
Verified Customer
Verified customer
Asked: 2019-07-05
Answer
The products we sell, including anti-Olfactory receptor 10G2 antibody A18230, are only intended for research use. They would not be suitable for use in diagnostic work. If you have the means to develop a product into diagnostic use, and are interested in collaborating with us and develop our product into an IVD product, please contact us for more discussions.
Boster Scientific Support
Answered: 2019-07-05
Question
Will anti-Olfactory receptor 10G2 antibody A18230 work on zebrafish WB with lung?
E. Dhar
Verified customer
Asked: 2019-03-15
Answer
Our lab technicians have not validated anti-Olfactory receptor 10G2 antibody A18230 on zebrafish. You can run a BLAST between zebrafish and the immunogen sequence of anti-Olfactory receptor 10G2 antibody A18230 to see if they may cross-react. If the sequence homology is close, then you can perform a pilot test. Keep in mind that since we have not validated zebrafish samples, this use of the antibody is not covered by our guarantee. However we have an innovator award program that if you test this antibody and show it works in zebrafish lung in WB, you can get your next antibody for free.
Boster Scientific Support
Answered: 2019-03-15
Question
My question regarding product A18230, anti-Olfactory receptor 10G2 antibody. I was wondering if it would be possible to conjugate this antibody with biotin. I would need it to be without BSA or sodium azide. I am planning on using a buffer exchange of sodium azide with PBS only. Would there be problems for me to conjugate the antibody and store it in -20 degrees in small aliquots?
M. Li
Verified customer
Asked: 2019-02-19
Answer
We do not advise storing this antibody with PBS buffer only in -20 degrees. If you want to store it in -20 degrees it is best to add some cryoprotectant like glycerol. If you want carrier free A18230 anti-Olfactory receptor 10G2 antibody, we can provide it to you in a special formula with trehalose and/or glycerol. These molecules will not interfere with conjugation chemistry and provide a good level of protection for the antibody from degradation. Please be sure to specify this in your purchase order.
Boster Scientific Support
Answered: 2019-02-19