PLCD1 antibody (A05094-1) performs well in ELISA, Flow Cytometry, WB and shows reactivity with Human, Mouse, Rat.

  • Validated for inter-lot consistency, specificity, and reproducibility
  • Committed to quality since 1993
Filter:
a05094 1 plcd1 primary antibodies wb testing 1a05094 1 plcd1 primary antibodies fcm testing 1

Anti-PLCD1 Antibody Picoband®

PLCD1 antibody

Reactive SpeciesHostApplication
Human, Mouse, RatRabbitELISA, Flow Cytometry, WB

SKU: A05094-1

Size: 100 μg

Bundle to save: I do not want free secondary ab
Price:
$370/100 μg

In stock. Ships Next Business Day.

Quantity: 1

1
Get A Quote
Guarantee / Product Promise

Tested Applications

PLCD1 antibody was positively detected by WB in:

rat lung tissue, rat heart tissue, mouse lung tissue, mouse heart tissue

Suggested blocking solution with 5% non-fat milk or BSA; (*)Recommended protein loading: 20-40 ug per lane

PLCD1 antibody was positively detected by FC in:

293T cell

Recommend Dilution

Application
Dilution
Species
Western blot
0.25-0.5 μg/ml
Mouse, Rat
Flow Cytometry (Fixed)
1-3 μg/1x106 cells
Human
ELISA
0.1-0.5 μg/ml

* It is recommended to optimize the amount of this reagent in each experimental system to achieve the best results.

Note: For flow cytometry (FCM), validated for fixed cells only. Not validated for FACS or surface flow cytometry using live cells.

Reactive Data

Filter:
Boster Guarantee:What is this?
WB
ELISA
Rat
Tested
Recommend
Mouse
Tested
Recommend
Human
Recommend
Monkey
Predicted
Predicted
Dog
Predicted
Predicted
Sheep
Predicted
Predicted
Bovine
Predicted
Predicted

Product Information

Product Name
Anti-PLCD1 Antibody Picoband®
View all PLCD1 Antibodies
Form
Lyophilized
Uniprot
Gene ID
Storage & Handling
At -20°C for one year from date of receipt. After reconstitution, at 4°C for one month. It can also be aliquotted and stored frozen at -20°C for six months. Avoid repeated freezing and thawing.
Host
Rabbit
Contents
Each vial contains 4 mg Trehalose, 0.9 mg NaCl, 0.2 mg Na2HPO4.
Clonality
Polyclonal
Immunogen
E.coli-derived human PLCD1 recombinant protein (Position: Q14-R549). Human PLCD1 shares 92.2% and 92.5% amino acid (aa) sequence identity with mouse and rat PLCD1, respectively.
Reconstitution
Adding 0.2 ml of distilled water will yield a concentration of 500 μg/ml.
Observed Molecular Weight
86 kDa
Calculated Molecular Weight

85.7 kDa

Background of PLCD1
This gene encodes a member of the phospholipase C family. Phospholipase C isozymes play critical roles in intracellular signal transduction by catalyzing the hydrolysis of phosphatidylinositol 4,5-bisphosphate (PIP2) into the second messengers diacylglycerol (DAG) and inositol triphosphate (IP3). The encoded protein functions as a tumor suppressor in several types of cancer, and mutations in this gene are a cause of hereditary leukonychia. Alternatively spliced transcript variants encoding multiple isoforms have been observed for this gene.
Cite This Product
Anti-PLCD1 Antibody Picoband® (Boster Biological Technology, Pleasanton CA, USA, Catalog # A05094-1)

Protocols

Western Blot protocol for PLCD1 antibody
Flow Cytometry (FC) protocol for PLCD1 antibody

Review

Have you used Anti-PLCD1 Antibody Picoband®?

Submit a review and receive $370 in product credits, a $185 Amazon gift card, or our carefully curated gift bundles.

Product Promise

We promise Anti-PLCD1 Antibody Picoband® performs excellently in relevant applications for ELISA, Flow Cytometry, WB. If it doesn't perform as promised, we will refund the product. Learn more

In stock
Order Product
A05094-1
Buy one primary antibody get one 0.5ml HRP or Biotin secondary antibody for free.
*Sample sizes are prepared on demand and will take extra lead time. (cannot be conjugated)
$370.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.

This product is for Research Use Only. Not for use in diagnostic procedures.

Update date: Oct 14, 2026