Boster Bio Life Science Blog

Elevate your ELISA performance with focused guidance on sample preparation, standard curve design, and common troubleshooting. Ensure accuracy and reproducibility with expert support.
  1. Which ELISA is for you?

    Are you familiar with the multiple methods you could use to perform an ELISA, including the wide range of commercially available elisa kits designed for different targets and sensitivity requirements? Among the standard

    ...
    Read more
    Which ELISA is for you?
  2. ELISA Troubleshooting Saturated Signals

    If you are having trouble with saturated signals in your ELISA data results, check out this table for Boster’s possible solutions to your problem:

    Possible Causes Possible Solutions
    High sample concentration Use higher sample dilutions (Determine the optimal dilutions by titration assay). In parallel, construct an ELISA standard curve using known concentrations to more accurately map signal intensities to antigen levels.
    Excessive substrate Decrease concentration or amount of substrate: Follow manufacturer guidelines (The substrate provided with the ELISA kit might require further dilution)
    Substrate color changed before use Make substrate immediately before use
    Non-specific antibody binding Try different formulations in coating solutions; Ensure wells are pre-processed to prevent non-specific binding; Use affinity-purified antibody and preferably one that is pre- adsorbed; Use serum (5-10%) from same species as secondary antibody (bovine serum is also recommended).
    Incubation time too long Follow the manufacturer guidelines (If the problem persists, try incubating samples at 4°C overnight)
    Excess antibody Repeat the assay with lower antibody concentrations to find the optimal one for your experiment
    Contaminated buffers with metals or HRP Make and use fresh buffers
    ...
    Read more
  3. Guidelines for Preparing ELISA Standards

    ELISA (enzyme-linked immunosorbent assay) is a plate-based assay used to detect the concentration of a specific protein in a liquid sample and is frequently customized as part of custom assay development services tailored to specific research goals. In applications that require simultaneous measurement of multiple targets, researchers may also utilize multiplex ELISA kits to analyze several proteins within a single sample. It is also commonly performed using standardized elisa kits to ensure consistency across experiments. Three different types of data output can be obtained:

    Types of Data Output

    • Qualitative: ELISAs can be used to determine whether or not the protein of interest is present in the sample by comparing
    • ...
    Read more
    Guidelines for Preparing ELISA Standards
  4. 5 Pitfalls to Avoid for ELISA

    ELISA (enzyme-linked immunosorbent assay) is a convenient and simple method to quantitatively or qualitatively detect peptides, proteins, antibodies, and hormones in samples, rendering it as one of the most widely used immunoassays. Many laboratories perform these assays using standardized elisa kits, which help streamline assay setup and improve reproducibility. To derive accurate concentrations from measured signals, most ELISA protocols rely on constructing an standard curve from known standards, which serves as the reference for sample interpolation, alongside the use of quick elisa kits to support faster and more efficient assay workflows. Despite the many advantages of conducting ELISA—or more complex formats like those used in <...

    Read more
    5 Pitfalls to Avoid for ELISA
  5. How to Choose a Good ELISA Kit

    ELISA (Enzyme-Linked Immunosorbent Assay) remains one of the most widely used methods for protein quantification in immunology, oncology, neuroscience, biomarker discovery, and translational research. Researchers use ELISA to measure cytokines, chemokines, growth factors, hormones, signaling proteins, and disease biomarkers across a wide range of sample types.

    However, choosing an ELISA kit is often more complicated than selecting the target protein alone.

    Two ELISA kits for the same analyte may differ significantly in:

    • ELISA format
    • Sensitivity and detection range
    • Sample compatibility
    • Validation quality
    • Specificity and cross-reactivity
    • Reproducibility
    • Workflow design
    • Technical support

    These differences can directly affect data quality, quantitative reliability, and experimental reproducibility.

    This guide summarizes the key factors researchers should evaluate before selecting an ELISA kit...

    Read more
    How to Choose a Good ELISA Kit
  6. How To Perfect Your ELISA Standards

    At Boster, one common question we get from researchers is, “How do I prepare the ELISA standard?” We’re glad you asked because proper construction of the standard curve is the very first step for every ELISA experiment.The standard curve can help confirm that the quality of th...

    Read more
    How To Perfect Your ELISA Standards