Product Info Summary
| SKU: | EK0960 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Human |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Human ANGPTL4 / Angiopoietin Like 4 / ARP4 ELISA Kit PicoKine®
SKU/Catalog Number
EK0960
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human ANGPTL4 / Angiopoietin Like 4 / ARP4 ELISA Kit PicoKine® (96 Tests). Quantitate Human ANGPTL4 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 20pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human ANGPTL4 / Angiopoietin Like 4 / ARP4 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0960)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: L165-S406
Capture/Detection Antibodies
The capture antibody is monoclonal antibody from mouse and the detection antibody is polyclonal antibody from goat.
Sensitivity
<20 pg/ml
Assay Range
625 pg/ml - 40,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0960 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0960 is reactive to ANGPTL4 in Human samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK0960 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of ANGPTL4
Angiopoietin-related protein 4 (Angptl4) is a protein that in humans is encoded by the ANGPTL4 gene. This gene is a member of the angiopoietin/angiopoietin-like gene family and encodes a glycosylated, secreted protein with a fibrinogen C-terminal domain. This gene is induced under hypoxic conditions in endothelial cells and is the target of peroxisome proliferation activators. By radiation hybrid analysis, Angptl4 gene is mapped to 19p13.3. ANGPTL4 contributed to tumor growth and protected cells from anoikis, a form of programmed cell death induced when contact-dependent cells detach from the surrounding tissue matrix.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0960-CAP | Anti-Human ANGPTL4 Pre-coated 96-well strip microplate | 1 |
| EK0960-ST | Human ANGPTL4 Standard | 2 vials, 40 ng/tube |
| EK0960-DA | Human ANGPTL4 Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
| Concentration (ng/ml) | 0 | 0.625 | 1.25 | 2.5 | 5 | 10 | 20 | 40 |
| O.D. | 0.018 | 0.054 | 0.105 | 0.189 | 0.458 | 0.759 | 1.468 | 2.067 |
Data Example Images
Click image to see more details
Human ANGPTL4 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect ANGPTL4, Dilution ratio of 1:1, concentration in serum and plasma is around 1.2 ng/ml..
Some articles we found to cite concentrations of ANGPTL4 in samples: 24626437 (Pubmed IDs).
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human ANGPTL4 / Angiopoietin Like 4 / ARP4 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 1114 | 4583 | 20920 | 1120 | 4790 | 21489 |
| Standard deviation | 73.52 | 256.64 | 941.4 | 79.52 | 320.93 | 988.49 |
| CV (%) | 6.6% | 5.6% | 4.5% | 7.1% | 6.7% | 4.6% |
Specific Publications For Human ANGPTL4 / Angiopoietin Like 4 / ARP4 ELISA Kit PicoKine® (EK0960)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Human ANGPTL4 / Angiopoietin Like 4 / ARP4 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
4 Customer Q&As for Human ANGPTL4 / Angiopoietin Like 4 / ARP4 ELISA Kit PicoKine®
Question
Q: can you suggest the dilution ratio of serum samples for detection of ANGPTL4 in Human serum? I am trying to measure a a number of analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.
B. Kapoor
Verified customer
Asked: 2020-06-19
Answer
A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the ANGPTL4 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/elisa-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2020-06-19
Question
Q: What is the optimal O.D. value for ANGPTL4 ELISA kit? I used your ANGPTL4 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain ANGPTL4 even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2019-08-13
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this ANGPTL4 ELISA kit to have sensitivity of 20pg/ml, that means the minimum amount of ANGPTL4 that can be declared/interpreted as positive by the above standard is 20pg/ml.
Boster Scientific Support
Answered: 2019-08-13
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2018-10-01
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2018-10-01
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis ANGPTL4 using the EK0960 Human ANGPTL4 Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2018-04-07
Answer
A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to avoid protein degradation.
Boster Scientific Support
Answered: 2018-04-07