Product Info Summary
| SKU: | EK0868 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Human |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA). |
Product info
Product Name
Human DKK-4 / Dickkopf 4 ELISA Kit PicoKine®
SKU/Catalog Number
EK0868
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human DKK-4 / Dickkopf 4 ELISA Kit PicoKine® (96 Tests). Quantitate Human DKK4 in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human DKK-4 / Dickkopf 4 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0868)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: L19-L224
Capture/Detection Antibodies
The capture antibody is monoclonal antibody from mouse and the detection antibody is polyclonal antibody from goat.
Sensitivity
<10 pg/ml
Assay Range
156 pg/ml - 10,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0868 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0868 is reactive to DKK4 in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA).
Application Guarantee
EK0868 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of DKK4
DKK4 is a membersof the Dickkopf family which are negative regulators of the growth-promoting Wnt / beta-catenin signaling pathway. By FISH, the DKK4 gene was mapped to chromosome 8p11.2-p11.1. The secreted protein contains two cysteine rich regions and is involved in embryonic development through its interactions with the Wnt signaling pathway. Activity of this protein is modulated by binding to the Wnt co-receptor and the co-factor kremen 2. The expression of DKK4 was significantly reduced in hepatocellular carcinomas (HCCs), particularly in HCCs that showed cytoplasmic beta- catenin accumulation. DKK4 expression was also reduced in HCC cell lines. Ectopic expression of DKK4 in 2 HCC cell lines reduced beta-catenin and cyclin D1 protein levels and attenuated beta-catenin activity in reporter gene assays.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0868-CAP | Anti-Human DKK4 Pre-coated 96-well strip microplate | 1 |
| EK0868-ST | Human DKK4 Standard | 2 vials, 10 ng/tube |
| EK0868-DA | Human DKK4 Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 156 | 312 | 625 | 1250 | 2500 | 5000 | 10000 |
| O.D. | 0.047 | 0.071 | 0.105 | 0.177 | 0.313 | 0.569 | 1.059 | 1.881 |
Data Example Images
Click image to see more details
Human DKK-4 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect DKK4, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 156 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human DKK-4 / Dickkopf 4 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 238 | 1092 | 4513 | 249 | 988 | 4453 |
| Standard deviation | 14.99 | 519.427 | 342.98 | 19.42 | 55.32 | 395.6%1 |
| CV (%) | 5.6%% | 5.3% | 7.6% | 7.8% | 5.6% | 8.9% |
Specific Publications For Human DKK-4 / Dickkopf 4 ELISA Kit PicoKine® (EK0868)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Human DKK-4 / Dickkopf 4 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
7 Customer Q&As for Human DKK-4 / Dickkopf 4 ELISA Kit PicoKine®
Question
Q: if the enzyme conjugated Dkk-4 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Dkk-4 antigen?
K. Chakrabarti
Verified customer
Asked: 2020-05-09
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2020-05-09
Question
Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?
M. Nelson
Verified customer
Asked: 2020-02-04
Answer
A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can effect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2020-02-04
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2019-09-24
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/elisa-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/elisa-data-analysis-instructions
Boster Scientific Support
Answered: 2019-09-24
Question
Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification Dkk-4 using the EK0868 Human Dkk-4 Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2019-04-30
Answer
A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to limit protein degradation.
Boster Scientific Support
Answered: 2019-04-30
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2019-04-28
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2019-04-28
Question
Q: how can I thaw whole blood sample for Dkk-4 ELISA after freezing?
Verified Customer
Verified customer
Asked: 2018-12-08
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test Dkk-4 for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.
Boster Scientific Support
Answered: 2018-12-08
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
W. Zhou
Verified customer
Asked: 2015-03-30
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2015-03-30