Overview
Product Name |
Human Eotaxin / CCL11 ELISA Kit PicoKine™
See more CCL11/Eotaxin products |
Catalog# |
EK0329 |
Storage & Handling |
Store at -20˚C for one year from date of receipt. After reconstitution, at 4˚C for one month. It can also be aliquotted and stored frozen at -20˚C for six months. Avoid repeated freeze-thaw cycles. |
Description |
Human Eotaxin / CCL11 ELISA Kit PicoKine™ (96 Tests). Quantitate Human CCL11 in cell culture supernatants, serum and plasma (citrate, EDTA).. Sensitivity: 2pg/ml. |
Cite This Product |
Human Eotaxin / CCL11 ELISA Kit PicoKine™ (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0329)
|
ELISA Validation |
ELISA Validation Information
|
Product Specs
Reactivity/Species |
Human |
Applications |
ELISA
*Our Boster Guarantee covers the use of this product in the above
tested applications.
**For positive and negative control design, consult "Tissue specificity" under
"Protein Target Info" tab. |
Sample Type |
cell culture supernatants, serum and plasma (citrate, EDTA). |
Sensitivity |
<2 pg/ml |
Assay Range |
15.6 pg/ml - 1,000 pg/ml |
Immunogen/Standard |
Expression system for standard: E.coli; Immunogen sequence: G24-P97 |
Antibody Clonalities |
Capture antibody|Detection antibody monoclonal antibody from mouse|polyclonal antibody from goat |
Cross Reactivity |
There is no detectable cross-reactivity with other relevant proteins. |
Pack Size |
96 wells/kit, with removable strips. |
Gene/Protein Basic Information For CCL11 (Source: Uniprot.org, NCBI)
Uniprot Id | P51671 |
---|
NCBI Gene Id | 6356 |
---|
Species Of This Entry | Human |
---|
Gene Name | CCL11 |
---|
Protein Name | Eotaxin |
---|
Superfamily | intercrine beta (chemokine CC) family |
---|
Alternative Names | CCL11/Eotaxin|C-C motif chemokine 11; CCL11; chemokine (C-C motif) ligand 11; Eosinophil chemotactic protein; Eotaxin; eotaxin-1; MGC22554; SCYA11Small-inducible cytokine A11; small inducible cytokine subfamily A (Cys-Cys), member 11 (eotaxin) |
---|
Molecular Weight | 10732 |
---|
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".
For more info on CCL11, check out the CCL11 Infographic
We have 30,000+ of these available, one for each gene! Check them out.
Want a nice infographic on your next protein? Boster's got them all. All proteins in the human genome, and some, can be found in the Boster Bio gene infographics. Download it and share it with your colleagues and friends. Big size posters available upon request.
In this infographic you will see the following information for CCL11: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. Some times it even contains some opt-ed articles the Boster team on the scientific news and clinical impacts of this protein, though not all have that. Too many proteins, you know.
Take me to the CCL11 infographic
Kit Components And Assay QC Data Details Of Human Eotaxin / CCL11 ELISA Kit PicoKine™
*The quality control (QC) data in this section is obtained from Boster's internal QC results and is for reference only. It may differ from the users' lab test results. The users can expect to generate data with similar linearity and quality demonstrated in the typical data but may not achieve exactly the same O.D. values.
Catalog number | Description | Quantity |
EK0329-CAP |
Anti-Human CCL11 Pre-coated 96-well strip microplate | 1 |
EK0329-ST | Human CCL11 Standard | 2 vials, 10 ng/tube |
EK0329-DA | Human CCL11 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
- Microplate Reader capable of reading absorbance at 450nm.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
This data is generated from a recent batch of EK0329 Human Eotaxin / CCL11 ELISA Kit PicoKine™. It is not necessarily the same data set used to generate the standard curve shown in the image of this product. TMB reaction incubate at 37°C for 15-25min
Concentration (pg/ml) | 0 | 15.6 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 |
O.D. | 0.030 | 0.091 | 0.167 | 0.301 | 0.568 | 1.134 | 1.877 | 2.273 |
We measured random samples of Human Eotaxin / CCL11 ELISA Kit PicoKine™ within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision |
---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 36 | 181 | 476 | 34 | 176 | 517 |
Standard deviation | 1.8 | 13.39 | 37.6 | 1.93 | 15.84 | 41.87 |
CV (%) | 5% | 7.4% | 7.9% | 5.7% | 9% | 8.1% |
We measured the performance consistency of Human Eotaxin / CCL11 ELISA Kit PicoKine™ to ensure the reproducibility of the assays. Three samples with differing target protein concentrations were assayed using four different lots.
Reproducibility
To assay reproducibility, three samples with differing target protein concentrations were assayed using four different lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|
Sample 1 | 36 | 31 | 34 | 34 | 33 | 1.78 | 5.3% |
Sample 2 | 181 | 203 | 202 | 192 | 194 | 8.9 | 4.5% |
Sample 3 | 476 | 507 | 504 | 491 | 494 | 12.25 | 2.4% |
*number of samples for each test n=16.
Specific Protocols
Boster provides comprehensive technical information for WB, IHC/IF/ICC, Flow Cytometry sample preparation protocols, assay protocols, troubleshooting tips and assay optimization tips.
Other Recommended Resources
Here are featured tools and databases that you might find useful.
Total number of citations: 1
Li L, Yu Ch, Ying Hz, Yu Jm. J Ethnopharmacol. 2013 May 2;147(1):238-44. Doi: 10.1016/J.Jep.2013.03.012. Epub 2013 Mar 15. Antiviral Effects Of Modified Dingchuan Decoction Against Respiratory Syncytial Virus Infection In Vitro And In An Immunosup... |
PubMed ID 23506991 |
Contact us with any questions at [email protected] or go to contact us
Questions and answers from customers related to EK0329 Human Eotaxin / CCL11 ELISA Kit PicoKine™
8 Related Questions
Question
Q: What is the optimal O.D. value for CCL11 ELISA kit? I used your CCL11 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain CCL11 even though the O.D. values are not very high?
Verified Customer
Asked: 2019-12-08
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the example mentioned, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CCL11 ELISA kit to have sensitivity of 2pg/ml, that means the minimum amount of CCL11 that can be declared/interpreted as positive by the above standard is 2pg/ml.
Boster Scientific Support
Answered: 2019-12-08
Question
Q: how are cell lysates prepared for use in Picokine® ELISA kits?
C. Lewis
Asked: 2019-10-04
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can have an affect on immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2019-10-04
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Asked: 2019-02-28
Boster Scientific Support
Answered: 2019-02-28
Question
Q: Can CCL11 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Asked: 2018-09-15
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is needed. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2018-09-15
Question
Q: is it okay to use heparin plasma as samples in Human CCL11 Picokine® ELISA Kit (Catalog # EK0329)?
E. Banerjee
Asked: 2017-04-09
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of CCL11 causing disruption of its protein structure. CCL11 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the CCL11 ELISA, treating samples with a number of anticoagulants and decided that citrate or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2017-04-09
Question
Q: if the enzyme conjugated CCL11 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CCL11 antigen?
Verified Customer
Asked: 2016-01-04
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2016-01-04
Question
Q: how to analyze ELISA data? I have obtained CCL11 level in plasma.
Verified Customer
Asked: 2015-08-29
Boster Scientific Support
Answered: 2015-08-29
Question
Q: how much samples can be assayed in a Picokine® ELISA Kit?
D. Anderson
Asked: 2014-03-20
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2014-03-20