Product info
Product Name
Human GHR/Growth Hormone R ELISA Kit PicoKine®
View all Growth Hormone R ELISA kits
SKU/Catalog Number
EK1467
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human GHR/Growth Hormone R ELISA Kit PicoKine™ (96 Tests). Quantitate Human GHR in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human GHR/Growth Hormone R ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1467)
Clonality of Antibodies
See Datasheet for details
Immunogen
Expression system for standard: NS0; Immunogen sequence: A27-Y264
Sensitivity
<15 pg/ml
Assay Range
156 pg/ml - 10,000 pg/ml
Standard Dilution Instructions
Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1467 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1467 is reactive to GHR in Human samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK1467 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Growth Hormone R
Growth hormone receptor is a protein that in humans is encoded by the GHR gene. It is mapped to chromosome 5p13.1-p12. This gene encodes a protein that is a transmembrane receptor for growth hormone. Binding of growth hormone to the receptor leads to receptor dimerization (the receptor may however also exist as a pre-assembled non-functional dimer) and the activation of an intra- and intercellular signal transduction pathway leading to growth. Mutations in this gene have been associated with Laron syndrome, also known as the growth hormone insensitivity syndrome (GHIS), a disorder characterized by short stature (proportional dwarfism).
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1467-CAP | Anti-Human GHR Pre-coated 96-well strip microplate | 1 |
EK1467-ST | Human GHR Standard | 2 vials, 10 ng/tube |
EK1467-DA | Human GHR Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Innovating Scientists Reward
If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.
Submit A Review
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 156 | 312 | 625 | 125000 | 25000 | 5000 | 10000 |
O.D. | 0.017 | 0.036 | 0.065 | 0.098 | 0.174 | 0.408 | 1.076 | 2.127 |
Data Example Images
Click image to see more details
Human GHR PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Growth Hormone R, Dilution ratio of 1:1, concentration in serum and plasma is around 4 ng/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human GHR/Growth Hormone R ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 353 | 1151 | 4591 | 351 | 1140 | 4805 |
Standard deviation | 20.47 | 66.75 | 192.82 | 25.8%7 | 71.82 | 201.81 |
CV (%) | 5.8% | 5.8% | 4.2% | 7.2% | 6.3% | 4.2% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of Growth Hormone R in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 353 | 349 | 346 | 304 | 338 | 19.78 | 5.8% |
Sample 2 | 1151 | 1302 | 1219 | 1248 | 1230 | 54.47 | 4.4% |
Sample 3 | 4591 | 4345 | 4168 | 3982 | 4271 | 224.72 | 5.2% |
Protein Target Info & Infographic
Gene/Protein Information For GHR (Source: Uniprot.Org, NCBI)
Gene Name
GHR
Full Name
Growth hormone receptor
Weight
71.5kDa
Superfamily
type I cytokine receptor family
Alternative Names
GH receptor; GHBP; GHR; growth hormone binding protein; Growth Hormone R; growth hormone receptor; serum binding protein; Somatotropin receptor GHR GHBP, GHIP growth hormone receptor growth hormone receptor|GH receptor|growth hormone binding protein|serum binding protein|somatotropin receptor
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on GHR, check out the GHR Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for GHR: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human GHR/Growth Hormone R ELISA Kit PicoKine® (EK1467)
Hello CJ!
No publications found for EK1467
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human GHR/Growth Hormone R ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
Be the first to review Human GHR/Growth Hormone R ELISA Kit PicoKine®
*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
5 Customer Q&As for Human GHR/Growth Hormone R ELISA Kit PicoKine®
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2020-04-30
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2020-04-30
Question
Q: can I use citrate plasma as samples in Human Growth Hormone R Picokine® ELISA Kit (Catalog # EK1467)?
Verified Customer
Verified customer
Asked: 2020-04-24
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of Growth Hormone R causing disruption of its protein structure. Growth Hormone R may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the Growth Hormone R ELISA, treating samples with various anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2020-04-24
Question
Q: Can Growth Hormone R ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2020-02-27
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2020-02-27
Question
Q: how are cell lysates prepared for use in Picokine® ELISA kits?
S. Mitchell
Verified customer
Asked: 2018-12-10
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2018-12-10
Question
Q: if the enzyme conjugated Growth Hormone R antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Growth Hormone R antigen?
S. Moore
Verified customer
Asked: 2018-09-27
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2018-09-27