Product Info Summary
| SKU: | EK2308 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Human |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, serum, plasma(heparin, EDTA) |
Product info
Product Name
Human IL-2R gamma ELISA Kit PicoKine®
SKU/Catalog Number
EK2308
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human IL-2R gamma ELISA Kit PicoKine® (96 Tests). Quantitate Human IL-2R gamma in cell culture supernatants, serum, plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human IL-2R gamma ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK2308)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: sf21; Immunogen sequence: Leu23-Asn254
Capture/Detection Antibodies
polyclonal antibody from goat|polyclonal antibody from goat
Sensitivity
<10 pg/mL
Assay Range
62.5-4,000 pg/mL
Standard Dilution Instructions

See datasheet of EK2308 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK2308 is reactive to IL2RG in Human samples
Validated Sample Types
cell culture supernatants, serum, plasma(heparin, EDTA)
Application Guarantee
EK2308 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of IL2RG
IL2RA(Interleukin 2 receptor, alpha), also called IL2R, IL2R, Alpha Chain or CD25, is a protein that in humans is encoded by the IL2RA gene.The IL2RA gene is mapped on 10p15.1. IL2RA is composed of strand-swapped "sushi-like" domains, unlike the classical cytokine receptor fold. As a result of this domain swap, IL2RA uses a composite surface to dock into a groove on IL2 that also serves as a binding site for antagonist drugs.Homodimeric alpha chains(IL2RA) result in low-affinity receptor, while homodimeric beta(IL2RB) chains produce a medium-affinity receptor. Normally an integral-membrane protein, soluble IL2RA has been isolated and determined to result from extracellular proteolyisis. Infection by the protozoan Trypanosoma cruzi causes Chagas disease, characterized by a reduction in the amount of IL2RA expressed on the surface of immune cells. This leads to chronic immune suppression, becoming increasingly severe over the course of many years and ultimately resulting in death if left untreated.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK2308-CAP | Anti-Human IL2RG Pre-coated 96-well strip microplate | 1 |
| EK2308-ST | Human IL2RG Standard | 2 vials, 10 ng/tube |
| EK2308-DA | Human IL2RG Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 62.5 | 125 | 250 | 500 | 1,000 | 2,000 | 4,000 |
| O.D. | 0.019 | 0.113 | 0.198 | 0.369 | 0.7 | 1.108 | 1.77 | 2.323 |
Data Example Images
Click image to see more details
Human IL-2R gamma PicoKine ELISA Kit standard curve
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human IL-2R gamma ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 73 | 388 | 1796 | 95 | 475 | 1666 |
| Standard deviation | 2.77 | 10.90 | 77.41 | 4.15 | 20.71 | 49.81 |
| CV (%) | 3.8% | 2.8% | 4.3% | 4.4% | 4.4% | 3.0% |
Specific Publications For Human IL-2R gamma ELISA Kit PicoKine® (EK2308)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Human IL-2R gamma ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question