Product Info Summary
| SKU: | EK0967 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Human |
| Application: | ELISA |
| Sample Types: | cell culture supernatants and cell lysates. |
Product info
Product Name
Human LYVE-1 ELISA Kit PicoKine®
SKU/Catalog Number
EK0967
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human LYVE-1 ELISA Kit PicoKine® (96 Tests). Quantitate Human LYVE1 in cell culture supernatants and cell lysates. Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human LYVE-1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0967)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: S24-T238
Capture/Detection Antibodies
The capture antibody is monoclonal antibody from mouse and the detection antibody is polyclonal antibody from goat.
Sensitivity
<10 pg/ml
Assay Range
31.2 pg/ml - 2,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0967 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0967 is reactive to LYVE1 in Human samples
Validated Sample Types
cell culture supernatants and cell lysates.
Application Guarantee
EK0967 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of LYVE1
Extracellular link domain containing 1, also known as LYVE-1 or XLKD1 is a human gene. The International Radiation Hybrid Mapping Consortium mapped the LYVE1 gene to chromosome 11p15.4. This gene encodes a type I integral membrane glycoprotein. The encoded protein acts as a receptor and binds to both soluble and immobilized hyaluronan. This protein may function in lymphatic hyaluronan transport and have a role in tumor metastasis. This gene may play a role in autocrine regulation of cell growth mediated by growth regulators containing cell surface retention sequence binding (CRS). It may act as a hyaluronan (HA) transporter, either mediating its uptake for catabolism within lymphatic endothelial cells themselves, or its transport into the lumen of afferent lymphatic vessels for subsequent re-uptake and degradation in lymph nodes.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0967-CAP | Anti-Human LYVE1 Pre-coated 96-well strip microplate | 1 |
| EK0967-ST | Human LYVE1 Standard | 2 vials, 10 ng/tube |
| EK0967-DA | Human LYVE1 Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 | 2000 |
| O.D. | 0.065 | 0.083 | 0.103 | 0.144 | 0.224 | 0.406 | 0.802 | 1.756 |
Data Example Images
Click image to see more details
Human LYVE-1 PicoKine ELISA Kit standard curve
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human LYVE-1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 82 | 287 | 987 | 78 | 288 | 893 |
| Standard deviation | 4.59 | 19.22 | 52.31 | 5.85 | 19.87 | 63.4 |
| CV (%) | 6.7%% | 6.7% | 5.3% | 7.5% | 6.9% | 7.1% |
Specific Publications For Human LYVE-1 ELISA Kit PicoKine® (EK0967)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
0 Reviews For Human LYVE-1 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
6 Customer Q&As for Human LYVE-1 ELISA Kit PicoKine®
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2020-11-24
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2020-11-24
Question
Can EK0967 be used to detect LYVE-1 in Human urine samples?
Verified customer
Asked: 2020-10-23
Answer
Our lab technicians have not validated the Human LYVE-1 ELISA Kit PicoKine EK0967 with urine samples, so we cannot guarantee that it would work. In theory, the ELISA kit will work for all sample types if the target protein is present at a level that falls within the linear range of the ELISA kit detection range. We guarantee the kit to work on the sample types that we have tested. For sample types that we have not tested for, we suggest you run pilot experiments to decide the optimal sample dilution.
Boster Scientific Support
Answered: 2020-10-23
Question
Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?
H. Adams
Verified customer
Asked: 2019-06-07
Answer
A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2019-06-07
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis LYVE-1 using the EK0967 Human LYVE-1 Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2019-04-09
Answer
A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. avoid repetitive freeze-thaw cycles with the stored samples in order to limit protein degradation.
Boster Scientific Support
Answered: 2019-04-09
Question
Q: can you suggest the dilution ratio of serum samples for detection of LYVE-1 in Human cell lysates? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.
D. Rodriguez
Verified customer
Asked: 2018-06-04
Answer
A: without knowing the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the LYVE-1 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/elisa-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2018-06-04
Question
Q: if the enzyme conjugated LYVE-1 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the LYVE-1 antigen?
Verified Customer
Verified customer
Asked: 2016-04-10
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2016-04-10