Human XCL1/Lymphotactin ELISA Kit PicoKine®

XCL1/Lymphotactin ELISA kit for Human

Human XCL1/Lymphotactin ELISA Kit PicoKine™ (96 Tests). Quantitate Human XCL1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 1pg/ml.

Product Info Summary

SKU: EK0802
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Human XCL1/Lymphotactin ELISA Kit PicoKine®

View all XCL1/Lymphotactin ELISA kits

SKU/Catalog Number

EK0802

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human XCL1/Lymphotactin ELISA Kit PicoKine™ (96 Tests). Quantitate Human XCL1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 1pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human XCL1/Lymphotactin ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0802)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: E.coli; Immunogen sequence: V22-G114

Sensitivity

<1 pg/ml

Assay Range

62.5 pg/ml - 4,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK0802 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0802 is reactive to XCL1 in Human samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0802 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of XCL1/Lymphotactin

Chemokine (C motif) ligand (XCL1) is a small cytokine belonging to the XC chemokine family that is also known as lymphotactin. This gene is mapped to chromosome 1q23 by FISH. The sequence of the deduced 114-amino acid protein is most homologous to the CC chemokines CCL8 and CCL3. It is found in high levels in spleen, thymus, intestine and peripheral blood leukocytes, and at lower levels in lung, prostate gland and ovary. XCL1 induces the migration of cells expressing XCR1.

Kit Components

Catalog Number Description Quantity
EK0802-CAP Anti-Human XCL1 Pre-coated 96-well strip microplate 1
EK0802-ST Human XCL1 Standard 2 vials, 10 ng/tube
EK0802-DA Human XCL1 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)062.5125250500100020004000
O.D.0.1420.1440.1460.1820.2280.3720.8331.717

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect XCL1/Lymphotactin, Dilution ratio of 1:1, concentration in serum and plasma is around 126 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human XCL1/Lymphotactin ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)12946612081184351181
Standard deviation8.5130.7554.369.236.6%372.04
CV (%)6.6%6.6%4.5%7.8%8.1%6.1%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of XCL1/Lymphotactin in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 11291301341461346.755%
Sample 246642044545644617.133.8%
Sample 31208126713891234127469.335.4%
*number of samples for each test n=16.

Gene/Protein Information For XCL1 (Source: Uniprot.Org, NCBI)

Gene Name

XCL1

Full Name

Lymphotactin

Weight

12.517kDa

Superfamily

intercrine gamma family

Alternative Names

ATAC; ATACSmall-inducible cytokine C1; C motif chemokine 1; chemokine (C motif) ligand 1; Cytokine SCM-1; LPTNSCM-1-alpha; LTNXC chemokine ligand 1; Lymphotactin; lymphotaxin; SCM-1 alpha; SCM-1; SCM1A; SCM-1a; SCYC1SCM1; single cysteine motif 1a; small inducible cytokine subfamily C, member 1 (lymphotactin); XCL1 XCL1 ATAC, LPTN, LTN, SCM-1, SCM-1a, SCM1, SCM1A, SCYC1 X-C motif chemokine ligand 1 lymphotactin|SCM-1-alpha|XC chemokine ligand 1|c motif chemokine 1|chemokine (C motif) ligand 1|cytokine SCM-1|lymphotaxin|single cysteine motif 1a|small inducible cytokine subfamily C, member 1 (lymphotactin)|small-inducible cytokine C1

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on XCL1, check out the XCL1 Infographic

XCL1 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for XCL1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK0802

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human XCL1/Lymphotactin ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Human XCL1/Lymphotactin ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

6 Customer Q&As for Human XCL1/Lymphotactin ELISA Kit PicoKine®

Question

Q: Can XCL1 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

B. Bhatt

Verified customer

Asked: 2020-10-05

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2020-10-05

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring XCL1 using the EK0802 Human XCL1 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-07-09

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample on-stat collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to limit protein degradation.

Boster Scientific Support

Answered: 2019-07-09

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

C. Williams

Verified customer

Asked: 2019-04-14

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2019-04-14

Question

Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2018-10-20

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can effect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2018-10-20

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2018-07-04

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2018-07-04

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2018-06-28

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2018-06-28

$499
In stock, 3+ left.

Order within 0 hours and 37 minutes to receive by Fri May 17

Get A Quote
In stock
Order Product
EK0802
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.