Mouse CD23/FCER2 ELISA Kit PicoKine®

CD23/Fc epsilon RII ELISA kit for Mouse

Mouse CD23/FCER2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Fcer2 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 2 publication(s).

Product Info Summary

SKU: EK0924
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse CD23/FCER2 ELISA Kit PicoKine®

View all CD23/Fc epsilon RII ELISA kits

SKU/Catalog Number

EK0924

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse CD23/FCER2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Fcer2 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse CD23/FCER2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0924)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: E50-P331

Sensitivity

<15 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0924 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0924 is reactive to Fcer2 in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0924 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CD23/Fc epsilon RII

CD23, also known as Fc epsilon RII, or FcεRII, is the "low-affinity" receptor for IgE, an antibody isotype involved in allergy and resistance to parasites, and is important in regulation of IgE levels. There are two forms of CD23: CD23a and CD23b. CD23a is present on follicular B cells, whereas CD23b requires IL-4 to be expressed on T-cells, monocytes, Langerhans cells, eosinophils, and macrophages. As part of a mapping of multiple probes to specific bands on chromosome 19 by fluorescence in situ hybridization, the CD23 gene was assigned to 19p13.3. And CD23 (FCE2) is a key molecule for B-cell activation and growth. It is the low-affinity receptor for IgE. The truncated molecule can be secreted, then functioning as a potent mitogenic growth factor.

Kit Components

Catalog Number Description Quantity
EK0924-CAP Anti-Mouse Fcer2 Pre-coated 96-well strip microplate 1
EK0924-ST Mouse Fcer2 Standard 2 vials, 10 ng/tube
EK0924-DA Mouse Fcer2 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512502500500010000
O.D.0.0210.0450.1370.2790.5091.0091.5032.041

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CD23/Fc epsilon RII, Dilution ratio of 1:1, concentration in serum and plasma is around 400 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse CD23/FCER2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)2561831585323418815493
Standard deviation11137.32345.3212.87156.12373.52
CV (%)4.3%7.5%5.9%5.5%8.3%6.8%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CD23/Fc epsilon RII in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 125629629325427419.797.2%
Sample 21831167216091822173395.685.5%
Sample 358535387522152685432250.344.6%
*number of samples for each test n=16.

Gene/Protein Information For Fcer2 (Source: Uniprot.Org, NCBI)

Gene Name

Fcer2

Full Name

Low affinity immunoglobulin epsilon Fc receptor

Weight

37648 MW

Alternative Names

Low affinity immunoglobulin epsilon Fc receptor;Fc-epsilon-RII;Lymphocyte IgE receptor;CD23;Fcer2;Fcer2a; FCER2 BLAST-2, CD23, CD23A, CLEC4J, FCE2, IGEBF Fc fragment of IgE receptor II low affinity immunoglobulin epsilon Fc receptor|C-type lectin domain family 4, member J|CD23 |Fc epsilon receptor II|Fc fragment of IgE, low affinity II, receptor for (CD23)|fc-epsilon-RII|immunoglobulin E-binding factor|immunoglobulin epsilon-chain|lymphocyte IgE receptor

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Fcer2, check out the Fcer2 Infographic

Fcer2 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Fcer2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK0924 has been cited in 2 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Rubusoside alleviates the ovalbumin‐induced mice allergic asthma by modulating the NF‐κB activation

Bronchial epithelial pyroptosis promotes airway inflammation in a murine model of toluene diisocyanate-induced asthma

Have you used Mouse CD23/FCER2 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Mouse CD23/FCER2 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

7 Customer Q&As for Mouse CD23/FCER2 ELISA Kit PicoKine®

Question

Q: we need your suggestion regarding the dilution ratio of serum samples for detection of CD23 in Mouse cell lysates? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have limited sample volumes so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2020-11-07

Answer

A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CD23 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2020-11-07

Question

Q: how to analyze ELISA data? I have obtained CD23 level in cell lysates.

Verified Customer

Verified customer

Asked: 2019-11-19

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2019-11-19

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement CD23 using the EK0924 Mouse CD23 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-10-02

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to avoid protein degradation.

Boster Scientific Support

Answered: 2019-10-02

Question

Q: how to thaw whole blood sample for CD23 ELISA after freezing?

Verified Customer

Verified customer

Asked: 2019-09-28

Answer

A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CD23 for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.

Boster Scientific Support

Answered: 2019-09-28

Question

Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2019-09-16

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer may affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2019-09-16

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2019-08-14

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2019-08-14

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2017-03-15

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2017-03-15

$499
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
In stock
Order Product
EK0924
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.