Mouse HRG ELISA Kit PicoKine®

HPRG ELISA kit for Mouse

Mouse HRG ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Hrg in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml .

Product Info Summary

SKU: EK1708
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA).

Product Name

Mouse HRG ELISA Kit PicoKine®

View all HPRG ELISA kits

SKU/Catalog Number

EK1708

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse HRG ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Hrg in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml .

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse HRG ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1708)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: L19-K525

Sensitivity

<10 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1708 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1708 is reactive to HRG in Mouse samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA).

Application Guarantee

EK1708 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of HPRG

HRG is a glycoprotein that in humans is encoded by the HRG gene. The HRG protein is produced in the liver, and it could also be synthesized by monocytes, macrophages, and megakaryocytes. It possesses a multi-domain structure, which makes it capable of binding to numerous ligands and modulating various biological processes including immunity, vascularization and coagulation.

Kit Components

Catalog Number Description Quantity
EK1708-CAP Anti-Mouse HRG Pre-coated 96-well strip microplate 1
EK1708-ST Mouse HRG Standard 2 vials, 10 ng/tube
EK1708-DA Mouse HRG Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631362512502500500010000
O.D.0.0250.0820.1150.1970.4520.8011.4322.144

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect HPRG, Dilution ratio of 1:100000, concentration in serum and plasma is around 200 ug/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse HRG ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3121100425931412994301
Standard deviation12.7949.5264.0617.2775.34326.88
CV (%)4.1%4.5%6.2%5.5%5.8%7.6%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of HPRG in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 131227330228929414.614.9%
Sample . 21100102610141099105939.973.7%
Sample 342594189493246094497297.186.6%
*number of samples for each test n=16.

Gene/Protein Information For HRG (Source: Uniprot.Org, NCBI)

Gene Name

HRG

Full Name

Histidine-rich glycoprotein

Weight

59.578kDa

Alternative Names

DKFZp779H1622; Histidine-proline-rich glycoprotein; histidine-rich glycoprotein; HPRG; HPRGHRGP; HRG HRG HPRGP, THPH11, HRG histidine rich glycoprotein histidine-rich glycoprotein|histidine-proline-rich glycoprotein

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on HRG, check out the HRG Infographic

HRG infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for HRG: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1708

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse HRG ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Mouse HRG ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Mouse HRG ELISA Kit PicoKine®

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification HPRG using the EK1708 Mouse HPRG Picokine® ELISA Kit?

M. Hernandez

Verified customer

Asked: 2020-01-31

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to limit protein degradation.

Boster Scientific Support

Answered: 2020-01-31

Question

What is the recommended diluent rate for mouse plasma samples using EK1708?

Verified customer

Asked: 2020-01-09

Answer

The recommended dilution ratio for healthy mouse plasma samples with the HRG/HPRG PicoKineTM ELISA Kit (EK1708) is 1:1000.

Boster Scientific Support

Answered: 2020-01-09

Question

Q: What is the optimal O.D. value for HPRG ELISA kit? I performed your HPRG ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain HPRG even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-11-22

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this HPRG ELISA kit to have sensitivity of 10pg/ml , that means the minimum amount of HPRG that can be declared/interpreted as positive by the above standard is 10pg/ml .

Boster Scientific Support

Answered: 2019-11-22

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

K. Hill

Verified customer

Asked: 2019-08-28

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2019-08-28

Question

Q: Can HPRG ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-09-08

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-09-08

Question

Q: we need your recommendation regarding the dilution ratio of serum samples for detection of HPRG in Mouse plasma ? I am trying to measure a a number of analytes and it requires 100ul of diluted samples for each well. We have limited sample volumes so we like to dilute as much as possible.

J. Baker

Verified customer

Asked: 2016-12-03

Answer

A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the HPRG ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2016-12-03

Question

Q: how can I thaw whole blood sample for HPRG ELISA after freezing?

B. Dayal

Verified customer

Asked: 2016-11-24

Answer

A: we do not recommend freezing and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test HPRG for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.

Boster Scientific Support

Answered: 2016-11-24

Question

Q: how do I analyze ELISA data? I have performed HPRG level in plasma .

H. Clark

Verified customer

Asked: 2015-11-01

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2015-11-01

$499
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
In stock
Order Product
EK1708
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.