Rat VE-Cadherin Cdh5 ELISA Kit PicoKine®

VE-Cadherin ELISA kit for Rat

Rat VE-Cadherin Cdh5 ELISA Kit PicoKine™ (96 Tests). Quantitate Rat Cdh5 in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 50pg/ml. Cited in 1 publication(s).

Product Info Summary

SKU: EK1916
Size: 96 wells/kit, with removable strips.
Reactive Species: Rat
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA).

Product Name

Rat VE-Cadherin Cdh5 ELISA Kit PicoKine®

View all VE-Cadherin ELISA kits

SKU/Catalog Number

EK1916

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Rat VE-Cadherin Cdh5 ELISA Kit PicoKine™ (96 Tests). Quantitate Rat Cdh5 in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 50pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Rat VE-Cadherin Cdh5 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1916)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: D46 - Q599

Sensitivity

<50 pg/ml

Assay Range

312 pg/ml - 20,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1916 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1916 is reactive to CDH5 in Rat samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA).

Application Guarantee

EK1916 is guaranteed for ELISA in Rat by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of VE-Cadherin

Cadherin 5, type 2 or VE-cadherin also known as CD144, is a type of cadherin. It is encoded by the human gene CDH5. This gene is mapped to 19p14. VE-cadherin is a classical cadherin from the cadherin superfamily and the gene is located in a six-cadherin cluster in a region on the long arm of chromosome 16 that is involved in loss of heterozygosity events in breast and prostate cancer. The encoded protein is a calcium-dependent cell–cell adhesion glycoprotein composed of five extracellular cadherin repeats, a transmembrane region and a highly conserved cytoplasmic tail. Functioning as a classic cadherin by imparting to cells the ability to adhere in a homophilic manner, the protein may play an important role in endothelial cell biology through control of the cohesion and organization of the intercellular junctions.

Kit Components

Catalog Number Description Quantity
EK1916-CAP Anti-Rat CDH5 Pre-coated 96-well strip microplate 1
EK1916-ST Rat CDH5 Standard 2 vials, 20 ng/tube
EK1916-DA Rat CDH5 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)03126251250250050001000020000
O.D.0.0120.1470.2640.4630.8191.6132.1652.793

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect VE-Cadherin, Dilution ratio of 1:5, concentration in serum and plasma is around 16 ng/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Rat VE-Cadherin Cdh5 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3991935875844321948947
Standard deviation21.95123.84507.9627.47112.11653.13
CV (%)5.5%6.4%5.8%6.2%5.1%7.3%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of VE-Cadherin in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 139941044346742926.926.2%
Sample 21935219420132122206699.364.8%
Sample 387588677844786018620114.651.3%
*number of samples for each test n=16.

Gene/Protein Information For CDH5 (Source: Uniprot.Org, NCBI)

Gene Name

CDH5

Full Name

Cadherin-5

Weight

87.528kDa

Alternative Names

7B4 antigen; 7B4; cadherin 5, type 2 (vascular endothelium); cadherin 5, type 2, VE-cadherin (vascular epithelium); Cadherin-5; CD144 antigen; CD144; CDH5; endothelial-specific cadherin; FLJ17376; Vascular endothelial cadherin; VECadherin; VE-Cadherin CDH5 7B4, CD144 cadherin 5 cadherin-5|7B4 antigen|VE-cadherin|cadherin 5, type 2 (vascular endothelium)|cadherin 5, type 2, VE-cadherin (vascular epithelium)|cd144 antigen|endothelial-specific cadherin|vascular endothelial cadherin

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on CDH5, check out the CDH5 Infographic

CDH5 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for CDH5: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK1916 has been cited in 1 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Protective effect of co-administration of rosuvastatin and probucol on atherosclerosis in rats

Have you used Rat VE-Cadherin Cdh5 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Rat VE-Cadherin Cdh5 ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

7 Customer Q&As for Rat VE-Cadherin Cdh5 ELISA Kit PicoKine®

Question

Q: What is the optimal O.D. value for VE-Cadherin ELISA kit? I used your VE-Cadherin ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain VE-Cadherin even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-12-22

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this VE-Cadherin ELISA kit to have sensitivity of 50pg/ml, that means the minimum amount of VE-Cadherin that can be declared/interpreted as positive by the above standard is 50pg/ml.

Boster Scientific Support

Answered: 2019-12-22

Question

Q: is it okay to use citrate plasma as samples in Rat VE-Cadherin Picokine® ELISA Kit (Catalog # EK1916)?

Verified Customer

Verified customer

Asked: 2019-08-28

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can attach metal ions from the functional domain of VE-Cadherin causing disruption of its protein structure. VE-Cadherin may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the VE-Cadherin ELISA, treating samples with different anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2019-08-28

Question

Q: which procedure should I follow in order to thaw whole blood sample for VE-Cadherin ELISA after freezing?

Verified Customer

Verified customer

Asked: 2019-08-08

Answer

A: we do not recommend freezing and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test VE-Cadherin for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.

Boster Scientific Support

Answered: 2019-08-08

Question

Q: Can VE-Cadherin ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2019-06-28

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2019-06-28

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2018-08-05

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2018-08-05

Question

Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?

M. Collins

Verified customer

Asked: 2018-07-31

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer may affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2018-07-31

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis VE-Cadherin using the EK1916 Rat VE-Cadherin Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2017-07-02

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to prevent protein degradation.

Boster Scientific Support

Answered: 2017-07-02

$499
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
In stock
Order Product
EK1916
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.