SLC4A1 antibody (PB9437) performs well in Flow Cytometry, IF, IHC, IHC-F, WB and shows reactivity with Human, Mouse, Rat.

  • Validated for inter-lot consistency, specificity, and reproducibility
  • Committed to quality since 1993
  • Over 1 Publication
Filter:
pb9437 slc4a1 primary antibodies fcm testing 8pb9437 2_1 IHC anti band 3 picoband antibodypb9437 3_1 IHC anti band 3 picoband antibodypb9437 4 IHC anti band 3 picoband antibodypb9437 5 IHC anti band 3 picoband antibodypb9437 slc4a1 primary antibodies ihc testing 6pb9437 slc4a1 primary antibodies wb testing 1pb9437 6pb9437 7

Anti-SLC4A1/CD233/Band 3 Antibody Picoband®

SLC4A1 antibody

Reactive SpeciesHostApplication
Human, Mouse, RatRabbitFlow Cytometry, IF, IHC, IHC-F, WB

SKU: PB9437

Size: 100 μg

Bundle to save: I do not want free secondary ab
Price:
$370/100 μg

3 in stock. Ships Next Business Day.

Quantity: 1

1
Get A Quote
Guarantee / Product Promise

Tested Applications

SLC4A1 antibody was positively detected by WB in:

human K562 whole cell, human T-47D whole cell

Suggested blocking solution with 5% non-fat milk or BSA; (*)Recommended protein loading: 20-40 ug per lane

SLC4A1 antibody was positively detected by IHC in:

Rat Kidney tissue, Human Placenta tissue, Mouse Kidney tissue

Use TE buffer pH 9.0 for antigen retrieval; (*) citrate buffer pH 6.0 is an alternative.

SLC4A1 antibody was positively detected by IHC in:

Human Placenta tissue, human kidney tissue

Use TE buffer pH 9.0 for antigen retrieval; (*) citrate buffer pH 6.0 is an alternative.

SLC4A1 antibody was positively detected by IF in:

human placenta tissue, rat kidney tissue

SLC4A1 antibody was positively detected by FC in:

K562 cells

Recommend Dilution

Application
Dilution
Species
Western blot
0.1-0.5μg/ml
Human
Immunohistochemistry (Paraffin-embedded Section)
0.5-1μg/ml
Human, Mouse, Rat
Immunohistochemistry (Frozen Section)
0.5-1μg/ml
Human, -
Immunofluorescence
2μg/ml
Human, Rat
Flow Cytometry (Fixed)
1-3 μg/1x106 cells
Human

* It is recommended to optimize the amount of this reagent in each experimental system to achieve the best results.

Note: For flow cytometry (FCM), suitable for fixed cells only. Not suitable for FACS or surface flow cytometry using live cells.

Reactive Data

Filter:
Boster Guarantee:What is this?
WB
IHC
IF
Human
Tested
Tested
Tested
Rat
Tested
Tested
Mouse
Tested
Recommend
Monkey
Predicted
Predicted
Predicted

Product Information

Product Name
Anti-SLC4A1/CD233/Band 3 Antibody Picoband®
View all SLC4A1 Antibodies
Form
Lyophilized
Uniprot
Gene ID
Storage & Handling
Store at -20˚C for one year from date of receipt. After reconstitution, at 4˚C for one month. It can also be aliquotted and stored frozen at -20˚C for six months. Avoid repeated freeze-thaw cycles.
Host
Rabbit
Contents
Each vial contains 4 mg Trehalose, 0.9 mg NaCl and 0.2 mg Na2HPO4.
Clonality
Polyclonal
Isotype
Rabbit IgG
Immunogen
E. coli-derived human SLC4A1 (Position: E28-N365). Human SLC4A1 shares 75.7% and 74.5% amino acid (aa) sequence identity with mouse and rat SLC4A1, respectively.
Cross-Reactivity
No cross-reactivity with other proteins
Reconstitution
Add 0.2ml of distilled water will yield a concentration of 500ug/ml.
Observed Molecular Weight
102 kDa
Calculated Molecular Weight

101.8 kDa

Background of SLC4A1
Band 3 is also known as SLC4A1. The protein encoded by this gene is part of the anion exchanger (AE) family and is expressed in the erythrocyte plasma membrane, where it functions as a chloride/bicarbonate exchanger involved in carbon dioxide transport from tissues to lungs. The protein comprises two domains that are structurally and functionally distinct. The N-terminal 40kDa domain is located in the cytoplasm and acts as an attachment site for the red cell skeleton by binding ankyrin. The glycosylated C-terminal membrane-associated domain contains 12-14 membrane spanning segments and carries out the stilbene disulphonate-sensitive exchange transport of anions. The cytoplasmic tail at the extreme C-terminus of the membrane domain binds carbonic anhydrase II. The encoded protein associates with the red cell membrane protein glycophorin A and this association promotes the correct folding and translocation of the exchanger. This protein is predominantly dimeric but forms tetramers in the presence of ankyrin. Many mutations in this gene are known in man, and these mutations can lead to two types of disease: destabilization of red cell membrane leading to hereditary spherocytosis, and defective kidney acid secretion leading to distal renal tubular acidosis. Other mutations that do not give rise to disease result in novel blood group antigens, which form the Diego blood group system.
Cite This Product
Anti-SLC4A1/CD233/Band 3 Antibody Picoband® (Boster Biological Technology, Pleasanton CA, USA, Catalog # PB9437)

Protocols

Western Blot protocol for SLC4A1 antibody
Immunohistochemistry (IHC) protocol for SLC4A1 antibody
Immunofluorescence (IF) protocol for SLC4A1 antibody
Flow Cytometry (FC) protocol for SLC4A1 antibody

Publications

Application:
Species:
Early discovery of disseminated tumor cells during carcinogenesis in a 4NQO-induced mouse model of oral squamous cell carcinoma
Published: 2018-07-01
Journal: International Journal of Clinical and Experimental Pathology
Application: IHC
Impact Factor: 1.40
Species: Mouse
PMID: 31949709

Review

Have you used Anti-SLC4A1/CD233/Band 3 Antibody Picoband®?

Submit a review and receive $370 in product credits, a $185 Amazon gift card, or our carefully curated gift bundles.

Product Promise

We promise Anti-SLC4A1/CD233/Band 3 Antibody Picoband® performs excellently in relevant applications for Flow Cytometry, IF, IHC, IHC-F, WB. If it doesn't perform as promised, we will refund the product. Learn more

In stock
Order Product
PB9437
Buy one primary antibody get one 0.5ml HRP or Biotin secondary antibody for free.
*Sample sizes are prepared on demand and will take extra lead time. (cannot be conjugated)
$370.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.

This product is for Research Use Only. Not for use in diagnostic procedures.

Update date: Oct 4, 2026