Product Info Summary
| SKU: | A04914-1 |
|---|---|
| Size: | 100 μg/vial |
| Reactive Species: | Human, Mouse |
| Host: | Rabbit |
| Application: | Flow Cytometry, WB |
Customers Who Bought This Also Bought
Product info
Product Name
Anti-SLC22A3 Antibody Picoband®
SKU/Catalog Number
A04914-1
Size
100 μg/vial
Form
Lyophilized
Description
Boster Bio Anti-SLC22A3 Antibody Picoband® catalog # A04914-1. Tested in Flow Cytometry, WB applications. This antibody reacts with Human, Mouse. The brand Picoband indicates this is a premium antibody that guarantees superior quality, high affinity, and strong signals with minimal background in Western blot applications. Only our best-performing antibodies are designated as Picoband, ensuring unmatched performance.
Storage & Handling
Store at -20˚C for one year from date of receipt. After reconstitution, at 4˚C for one month. It can also be aliquotted and stored frozen at -20˚C for six months. Avoid repeated freeze-thaw cycles.
Cite This Product
Anti-SLC22A3 Antibody Picoband® (Boster Biological Technology, Pleasanton CA, USA, Catalog # A04914-1)
Host
Rabbit
Contents
Each vial contains 4mg Trehalose, 0.9mg NaCl, 0.2mg Na2HPO4, 0.01mg NaN3.
Clonality
Polyclonal
Isotype
Rabbit IgG
Immunogen
A synthetic peptide corresponding to a sequence at the N-terminus of human SLC22A3, which shares 76.5% amino acid (aa) sequence identity with both mouse and rat SLC22A3.
Cross-reactivity
No cross-reactivity with other proteins.
Reactive Species
A04914-1 is reactive to SLC22A3 in Human, Mouse
Observed Molecular Weight
61 kDa
Calculated molecular weight
61.3 kDa
Background of SLC22A3
Solute carrier family 22 (extraneuronal monoamine transporter), member 3, also known as SLC22A3 or OCT3 is a protein that in humans is encoded by the SLC22A3 gene. This gene is mapped to 6q25.3. Polyspecific organic cation transporters in the liver, kidney, intestine, and other organs are critical for elimination of many endogenous small organic cations as well as a wide array of drugs and environmental toxins. This gene mediates potential-dependent transport of a variety of organic cations. It may play a significant role in the disposition of cationic neurotoxins and neurotransmitters in the brain.
Antibody Validation
Boster validates all antibodies on WB, IHC, ICC, Immunofluorescence, and ELISA with known positive control and negative samples to ensure specificity and high affinity, including thorough antibody incubations.
Application & Images
Applications
A04914-1 is guaranteed for Flow Cytometry, WB Boster Guarantee
Assay Dilutions Recommendation
The recommendations below provide a starting point for assay optimization. The actual working concentration varies and should be decided by the user.
Western blot, 0.25-0.5μg/ml, Human, Mouse
Flow Cytometry (Fixed), 1-3μg/1x106 cells, Human
Positive Control
WB: human HEK293 whole cell, human Hela whole cell, mouse skeletal muscle tissue, mouse lung tissue
FCM: Hela cell
Validation Images & Assay Conditions
Click image to see more details
Western blot analysis of SLC22A3 using anti-SLC22A3 antibody (A04914-1).
Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 50ug of sample under reducing conditions.
Lane 1: human HEK293 whole cell lysates,
Lane 2: human Hela whole cell lysates,
Lane 3: mouse skeletal muscle tissue lysates,
Lane 4: mouse lung tissue lysates.
After Electrophoresis, proteins were transferred to a Nitrocellulose membrane at 150mA for 50-90 minutes. Blocked the membrane with 5% Non-fat Milk/ TBS for 1.5 hour at RT. The membrane was incubated with rabbit anti-SLC22A3 antigen affinity purified polyclonal antibody (Catalog # A04914-1) at 0.5 μg/mL overnight at 4°C, then washed with TBS-0.1%Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:5000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit (Catalog # EK1002) with Tanon 5200 system. A specific band was detected for SLC22A3 at approximately 61KD. The expected band size for SLC22A3 is at 61KD.
Click image to see more details
Flow Cytometry analysis of Hela cells using anti-SLC22A3 antibody (A04914-1).
Overlay histogram showing Hela cells stained with A04914-1 (Blue line). To facilitate intracellular staining, cells were fixed with 4% paraformaldehyde and permeabilized with permeabilization buffer. The cells were blocked with 10% normal goat serum. And then incubated with rabbit anti-SLC22A3 Antibody (A04914-1, 1μg/1x106 cells) for 30 min at 20°C. DyLight®488 conjugated goat anti-rabbit IgG (BA1127, 5-10μg/1x106 cells) was used as secondary antibody for 30 minutes at 20°C. Isotype control antibody (Green line) was rabbit IgG (1μg/1x106) used under the same conditions. Unlabelled sample without incubation with primary antibody and secondary antibody (Red line) was used as a blank control.
Specific Publications For Anti-SLC22A3 Antibody Picoband® (A04914-1)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Anti-SLC22A3 Antibody Picoband®?
Share your experimental results or join a short interview to earn up to $1,000 in product credits or other rewards.
0 Reviews For Anti-SLC22A3 Antibody Picoband®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question


