Mouse Endostatin ELISA Kit PicoKine®

Endostatin ELISA kit for Mouse

Mouse Endostatin ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Col18a1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. Cited in 4 publication(s).

Product Info Summary

SKU: EK1376
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse Endostatin ELISA Kit PicoKine®

View all Endostatin ELISA kits

SKU/Catalog Number

EK1376

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse Endostatin ELISA Kit PicoKine™ (96 Tests). Quantitate Mouse Col18a1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse Endostatin ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1376)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: H1591-K1774

Sensitivity

<10 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1376 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1376 is reactive to Col18a1 in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK1376 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Endostatin

Endostatin is a naturally-occurring 20-kDa C-terminal fragment derived from type XVIII collagen. It is reported to serve as an anti-angiogenic agent, similar to angiostatin and thrombospondin. And It is produced by proteolytic cleavage of collagen XVIII, a member of the multiplexin family that is characterized by interruptions in the triple helix creating multiple domains, by proteases such as cathepsins. Using a genomic clone as a probe for fluorescence in situ hybridization, Endostatin was mapped the COL18A1 gene to 21q22.3. By immunoprecipitation analysis using membrane fractions of human mammary epithelial cells, It showed that endostatin specifically bound to cell surface nucleolin with high affinity. Blockage of nucleolin with neutralizing antibody or knockdown of nucleolin by RNA interference countered the antiendothelial activity of endostatin and abrogated its antiangiogenic and antitumor activity in vivo.

Kit Components

Catalog Number Description Quantity
EK1376-CAP Anti-Mouse Col18a1 Pre-coated 96-well strip microplate 1
EK1376-ST Mouse Col18a1 Standard 2 vials, 10 ng/tube
EK1376-DA Mouse Col18a1 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Innovating Scientists Reward

If you are the first to review this product, or if you have results for a special sample, species or application this product is not validated in, share your results with us and receive product credits you can use towards any Boster products! Applicable to all scientists world wide.

Submit A Review

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512502500500010000
O.D.0.0400.1370.2590.4730.8071.3071.6832.010

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Endostatin, Dilution ratio of 1:50, concentration in serum and plasma is around 50 ng/ml..

Some articles we found to cite concentrations of Endostatin in samples: 22322847, 19595115 (Pubmed IDs).

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse Endostatin ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3061512472930814044765
Standard deviation12.2474.08316.8413.8677.22390.73
CV (%)4%4.9%6.7%4.5%5.5%8.2%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Endostatin in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 130629127931329713.194.4%
Sample 21512137915861539150476.875.1%
Sample 347293933439042184317288.236.6%
*number of samples for each test n=16.

Gene/Protein Information For Col18a1 (Source: Uniprot.Org, NCBI)

Gene Name

Col18a1

Full Name

Collagen alpha-1(XVIII) chain

Weight

182.172kDa

Superfamily

multiplexin collagen family

Alternative Names

antiangiogenic agent; COL18A1; collagen alpha-1(XVIII) chain; collagen, type XVIII, alpha 1; Endostatin; FLJ27325; FLJ34914; human type XVIII collagen10endostatin; KNO; KNO1MGC74745; Knobloch syndrome, type 1; KS; multi-functional protein MFP Col18a1|endo|collagen, type XVIII, alpha 1|collagen alpha-1(XVIII) chain|alpha-1(XVIII) collagen|endostatin|procollagen, type XVIII, alpha 1

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Col18a1, check out the Col18a1 Infographic

Col18a1 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Col18a1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK1376 has been cited in 4 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

IL-22-producing Th22 cells play a protective role in CVB3-induced chronic myocarditis and dilated cardiomyopathy by inhibiting myocardial fibrosis

IL-22-producing Th22 cells play a protective role in CVB3-induced chronic myocarditis and dilated cardiomyopathy by inhibiting myocardial fibrosis

Zhang Y, Qu Zh, Cui M, Guo C, Zhang Xm, Ma Ch, Sun Ws. Cancer Biol Ther. 2009 Mar;8(5):466-73. Epub 2009 Mar 21. Combined Endostatin And Trail Gene Transfer Suppresses Human Hepatocellular Carcinoma Growth And Angiogenesis In Nude Mice.

Fu Y, Zhao Z, Wu Y, Wu K, Xu X, Liu Y, Tong C. J Ethnopharmacol. 2012 Jan 6;139(1):26-33. Doi: 10.1016/J.Jep.2011.08.077. Epub 2011 Nov 10. Therapeutic Mechanisms Of Tongmai Dasheng Tablet On Tripterygium Glycosides Induced Rat Model For Premature...

Have you used Mouse Endostatin ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

Be the first to review Mouse Endostatin ELISA Kit PicoKine®

*The first user to submit a review for a product is eligible for Boster's Innovating Scientists Reward, which gives product credits. This is in addition to the gift card reward.

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

11 Customer Q&As for Mouse Endostatin ELISA Kit PicoKine®

Question

Q: Can Endostatin ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

D. Singh

Verified customer

Asked: 2020-08-30

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2020-08-30

Question

Q: how to proceed with the analysis of ELISA data? I have performed Endostatin level in plasma.

Verified Customer

Verified customer

Asked: 2020-06-24

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2020-06-24

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

L. Turner

Verified customer

Asked: 2020-02-19

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2020-02-19

Question

We have a customer who is interrested in your Mouse endostatin ELISA kit and have some questions: Does it also detect collagenXVIII (I am running the assay on the brain lysates that most likely contain both endostatin and unprocessed collagenXVIII)? You recommend using heparin or EDTA-coated vials for plasma collection. Can also citrate-coated vials be used? Or the assay would not work on citrate-plasma?

Verified Customer

Verified customer

Asked: 2019-12-23

Answer

1.We haven't had

Boster Scientific Support

Answered: 2019-12-23

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2019-08-08

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can have an affect on immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2019-08-08

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification Endostatin using the EK1376 Mouse Endostatin Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-05-30

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to limit protein degradation.

Boster Scientific Support

Answered: 2019-05-30

Question

Q: which procedure should I follow in order to thaw whole blood sample for Endostatin ELISA after freezing?

Verified Customer

Verified customer

Asked: 2019-05-29

Answer

A: we do not recommend freezing and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test Endostatin for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.

Boster Scientific Support

Answered: 2019-05-29

Question

Could you confirm what was used to raise the antibodies of EK1376? Was it a peptide or was it the full recombinant protein?

Verified customer

Asked: 2019-04-04

Answer

A recombinant protein (immunogen sequence: H1591-K1774) was used to raise the antibodies of the Mouse Endostatin ELISA Kit PicoKine™ (EK1376).

Boster Scientific Support

Answered: 2019-04-08

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2018-07-01

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-07-01

Question

Q: What is the optimal O.D. value for Endostatin ELISA kit? I performed your Endostatin ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain Endostatin even though the O.D. values are not very high?

L. Robinson

Verified customer

Asked: 2016-02-15

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this Endostatin ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of Endostatin that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2016-02-15

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2014-09-12

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is needed for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2014-09-12

$499
In stock, 1 left.

Order within 14 hours and 28 minutes to receive by Wed May 15

Get A Quote
In stock
Order Product
EK1376
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.