Product Info Summary
| SKU: | EK0568 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Mouse |
| Application: | ELISA |
| Sample Types: | cell culture supernatants and serum. |
Product info
Product Name
Mouse MCP-1 ELISA Kit PicoKine®
SKU/Catalog Number
EK0568
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse MCP-1 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Ccl2 in cell culture supernatants and serum. Sensitivity: 6pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse MCP-1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0568)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: E.coli; Immunogen sequence: Q24-R96
Capture/Detection Antibodies
The capture antibody is monoclonal antibody from rat and the detection antibody is polyclonal antibody from goat.
Sensitivity
<6 pg/ml
Assay Range
15.6 pg/ml - 1,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0568 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0568 is reactive to Ccl2 in Mouse samples
Validated Sample Types
cell culture supernatants and serum.
Application Guarantee
EK0568 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Ccl2
Monocyte chemotactic protein-1 (MCP-1) is a member of the small inducible gene (SIG) family. It has been shown to play a role in the recruitment of monocytes to sites of injury and infection. By analysis of a panel of somatic cell hybrids, we have localized the MCP-1 gene, designated SCYA2, to human chromosome 17. In situ hybridization confirmed this assignment and further localized the gene to 17q11.2-q21.1. MCP-1 plays a unique and crucial role in the initiation of atherosclerosis and may provide a new therapeutic target in this disorder. Monocyte chemoattractant protein-1 (MCP-1), regulated on activation, normal T cell expressed and secreted,and stimulation of monocytes from healthy carriers of the genotype GG with Mycobacterium tuberculosis antigens yielded higher MCP-1. The standard used in this kit is recombinant mouse MCP-1 (Q24-R96) with the molecular mass of 8.5Kda.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0568-CAP | Anti-Mouse Ccl2 Pre-coated 96-well strip microplate | 1 |
| EK0568-ST | Mouse Ccl2 Standard | 2 vials, 10 ng/tube |
| EK0568-DA | Mouse Ccl2 Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 15.6 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 |
| O.D. | 0.013 | 0.092 | 0.18 | 0.34 | 0.642 | 1.107 | 1.836 | 2.559 |
Data Example Images
Click image to see more details
Mouse MCP-1 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Ccl2, Dilution ratio of 1:1, concentration in serum is 51-259 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse MCP-1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 39 | 224 | 394 | 40 | 231 | 398 |
| Standard deviation | 1.56 | 10.75 | 27.18 | 2 | 12.47 | 27.46 |
| CV (%) | 4% | 4.8% | 6.9% | 5% | 5.4% | 6.9% |
Specific Publications For Mouse MCP-1 ELISA Kit PicoKine® (EK0568)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
1 Reviews For Mouse MCP-1 ELISA Kit PicoKine®
Good reproducible estimation--Divya Sharma, NDSU, Pharmaceutical Sciences, Graduate Student
Excellent

Source: Biocompare.com
| SKU | EK0568 |
|---|---|
| Application | ELISA |
| Sample | Centrifuged cell culture media supernatant |
| Detection | -- |
"Had to perform the analysis twice initially as the background wasn't clear. Overall, good reproducible estimation. Reliable, reproducible. Good product but would appreciate a faster assay kit with less chances of manual error." (Customer’s Tip: "Perform washing steps at least 6-7 times to get a clearer background with 60 seconds wait period in between each washing.")
Divya Sharma
Verified customer
Submitted 2019-05-21
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
7 Customer Q&As for Mouse MCP-1 ELISA Kit PicoKine®
Question
Q: how do I analyze ELISA data? I have performed CCL2 level in serum.
Verified Customer
Verified customer
Asked: 2020-08-07
Answer
A: we recommend you this article on ELISA data analysis. bosterbio.com/elisa-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/elisa-data-analysis-online
Boster Scientific Support
Answered: 2020-08-07
Question
Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2019-06-01
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2019-06-01
Question
Can you confirm if EK0394,EK0568,EK0527,EK0411 and EK0596 are compatible with ELISA microplate washers?
Verified customer
Asked: 2019-05-30
Answer
Our ELISA kits should be compatible for all ELISA microplate washers as long as it supports a 96 well plate.
Boster Scientific Support
Answered: 2019-05-30
Question
Can the sample diluent buffer, ABC diluent buffer and antibody diluent buffer be used interchangeably between the kit?
Verified customer
Asked: 2019-05-28
Answer
For the Mouse IL-1 Beta ELISA Kit PicoKine™ (EK0394), Mouse MCP-1 ELISA Kit PicoKine™ (EK0568), Mouse TNF Alpha ELISA Kit PicoKine™ (EK0527), Mouse IL-6 ELISA Kit PicoKine™ (EK0411) and Mouse Adiponectin ELISA Kit PicoKine™ (EK0596), the sample diluent buffer, ABC diluent buffer and antibody diluent buffer can be used interchangeably between the kit. However, the sample diluent buffer can only be used to dilute standards and samples, ABC diluent buffer is used to dilute ABC only and antibody diluent buffer is used to dilute antibody only.
Boster Scientific Support
Answered: 2019-05-29
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
W. Wright
Verified customer
Asked: 2017-08-30
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2017-08-30
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
C. Young
Verified customer
Asked: 2014-08-26
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/elisa-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/elisa-data-analysis-instructions
Boster Scientific Support
Answered: 2014-08-26
Question
Q: if the enzyme conjugated CCL2 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CCL2 antigen?
Verified Customer
Verified customer
Asked: 2014-05-22
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2014-05-22